Information
-
Ag Valley Coop Location
-
Conducted on
-
Prepared by
1.0 - Audit Comments
-
Comments
-
List of items needed from Safety Team
2.0 - Key Programs Required
-
2.1 - HAZCOM - SDS AVAILABLE FOR HAZARDOUS SUBSTANCES ON SITE
-
2.2 - Permit Required Confined Spaces Identified
-
2.3 - GAS METERS / Demonstrate
-
2.4 - FALL PROTECTION IN PLACE AND USED
-
2.5 - DOT / Interviews
-
2.6 - NEAR MISS / Interviews
3.0 - Emergency Action Plan
-
3.1 - Emergency Action Plan Initial Training for All Employees Completed?
-
3.2 - Emergency Action Plan Reviewed and Updated Annually?
-
3.3 - EAP / VISITORS LOGS used? (except customers)
-
3.4 - EAP / No additional corrective actions required?
4.0 - Lockout Tagout Safety Program
-
4.1 - LOTO / Initial and annual TRAINING documented for LOTO PROGRAM?
-
4.2 - LOTO / Machine specific WRITTEN PROCEDURES are complete?
-
4.3 - LOTO / Annual LOTO REVIEWS current within 12 months?
-
4.4 - LOTO / Required LOTO EQUIPMENT is available?
5.0 - Grain Handling Facility Safety Program
-
5.1 - GRAIN / Initial and annual training completed and documented?
-
5.2 - GRAIN / HOUSEKEEPING LOGS properly documented and certified by supervisor.?
-
5.3 - GRAIN / MAINTENANCE LOG properly documented and certified by supervisor?
-
5.4 - GRAIN / BIN ENTRY PERMITS are completed properly and maintained for at least 12 months?
-
5.5 - GRAIN / Boot pit and confined space ENTRY PERMITS completed properly and maintained for at least 12 months?
-
5.6 - GRAIN / No additional corrective actions required?
6.0 - Office Areas
-
6.1 - OFFICE / FIRE EXTINGUISHERS in place and properly mounted?
-
6.2 OFFICE / Monthly Fire Extinguisher inspections recorded on the tag?
-
6.3 - OFFICE / EGRESS routes well marked and clear of obstacles?
-
6.4 Office Emergency Lighting tested monthly?
-
6.5 - OFFICE / ELECTRICAL SYSTEMS compliant?
-
6.6 - OFFICE / Free of SLIP or TRIP hazards?
-
6.7 OFFICE / Platforms, Stairs and Handrails satisfactory?
-
6.8 - OFFICE / Facility SIGNAGE compliant?
-
6.9 - Electrical Circuit Breakers and Disconnects clearly identified?
-
6.10 - Clear access to electrical panels?
-
6.11 - OFFICE / CHEMICALS properly marked and stored?
-
6.12 Area around the office well kept and free of snow and ice?
-
6.13 - OFFICE / No additional corrective actions required?
7.0 - Grain Handling Areas
-
7.1 - MAIN LEVEL / FIRE EXTINGUISHERS in place and compliant?
-
7.2 - MAIN LEVEL / EGRESS routes kept clear of obstacles?
-
7.3 - MAIN LEVEL / ELECTRICAL EQUIPMENT SATISFACTORY?
-
7.4 - MAIL LEVEL / DUMP PIT GRATES COMPLIANT?
-
7.5 - MAIN LEVEL / ORGANIZED AND FREE OF CLUTTER, RUBBISH, AND SPILLED GRAIN?
-
7.6 - LOWER LEVELS / ORGANIZED AND FREE OF CLUTTER, RUBBISH, DUST, AND SPILLED GRAIN?
-
7.7 - LOWER LEVELS / FIRE EXTINGUISHERS IN PLACE AND COMPLIANT?
-
7.8 - LOWER LEVELS / EGRESS ROUTES KEPT CLEAR OF OBSTACLES?
-
7.9 - LOWER LEVELS / ELECTRICAL EQUIPMENT SATISFACTORY?
-
7.10 - UPPER LEVELS / ORGANIZED AND FREE OF CLUTTER, RUBBISH, DUST, AND SPILLED GRAIN?
-
7.11 - UPPER LEVELS / FIRE EXTINGUISHERS IN PLACE AND COMPLIANT?
-
7.12 - UPPER LEVELS / EGRESS ROUTES KEPT CLEAR OF OBSTACLES?
-
7.13 - UPPER LEVELS / ELECTRICAL EQUIPMENT SATISFACTORY?
-
7.14 - GRAIN / MACHINE GUARDING compliant?
-
7.15 - GRAIN / Free of SLIP or TRIP hazards?
-
7.16 - GRAIN / RAILINGS AND HOLE GUARDING compliant?
-
7.17 - GRAIN / LADDERS compliant?
-
7.18 - GRAIN / PERMIT SPACES properly marked?
-
7.19 - GRAIN / MAINTENANCE performed adequately?
-
7.20 - GRAIN / EMERGENCY RESCUE EQUIPMENT on site and stored properly? (Rope retrieval kit, plywood coffer dams, proper harness, and lifelines)
-
7.21 - GRAIN / Grain processing equipment MAGNETS are properly maintained?
-
7.22 - GRAIN / All CHEMICALS are properly stored and labeled?
-
7.23 - GRAIN / NO SMOKING WITHIN 50 FEET properly marked?
-
7.24 - GRAIN / EXTENSION CORDS are OSHA compliant including GFCI where required?
-
7.25 - GRAIN / Adequate SECURITY at facility? (Ladders, doors, electrical, overheads, etc.)
-
7.26 - GRAIN / LOADERS, skid steers etc. compliant and in safe operating condition?
-
7.27 - GRAIN / FACILITY SECURITY; Buildings lock securely
-
7.28 - GRAIN / No additional corrective actions required?
8.0 - Shop Areas
-
8.1 - SHOP / FIRE EXTINGUISHERS compliant?
-
8.2 - SHOP / EGRESS routes kept clear of obstacles?
-
8.3 - SHOP / ELECTRICAL SYSTEMS compliant?
-
8.4 - SHOP / MACHINE GUARDING compliant?
-
8.5 - SHOP / ORGANIZED and free of clutter and rubbish?
-
8.6 - SHOP / Free of SLIP or TRIP hazards?
-
8.7 - SHOP / RAILINGS and HOLE GUARDING compliant?
-
8.8 - SHOP / LADDERS compliant?
-
8.9 - SHOP / OILY RAGS and MATERIALS are placed in covered metal containers?
-
8.10 - SHOP / TOOLS are kept picked up and put away when not in use?
-
8.11 - SHOP / TOOLS and equipment are all OSHA compliant?
-
8.12 - SHOP / EXTENSION CORDS are OSHA compliant including GFCI where required?
-
8.13 - SHOP / All JACKS and HOISTS are marked with lifting capacities?
-
8.14 - SHOP / Proper PPE is available?
-
8.15 - SHOP / BATTERY CHARGING stations have flushing water near by?
-
8.16 - SHOP / CHEMICALS properly stored and labeled?
-
8.17 - SHOP / FLAMMABLES and AEROSOLS stored away from spark and heat producing equipment?
-
8.18 - SHOP / ALL FUELS are stored in OSHA compliant containers?
-
8.19 - SHOP / FLAMMABLES not stored in access or egress routes?
-
8.20 -SHOP / OXYGEN CYLINDERS stored properly? (Greater than 20 feet from combustibles/Flammables)
-
8.21 - SHOP / All STORED CYLINDERS are capped and secured from falling over?
-
8.22 - SHOP / PROPANE BOTTLES are not stored inside? (Gas grills stored indoors must have grill bottles removed)
-
8.23 - SHOP / USED OIL is placed in covered containers that are marked as "USED OIL"?
-
8.24 - SHOP / OVERHEAD STORAGE areas are marked with max load ratings.
-
8.25 - SHOP / STORAGE RACKS are secured and in good condition.
-
8.26 - SHOP / All WEED SPRAYERS are emptied and rinsed before placing or storing inside shops?
-
8.27 - SHOP / Proper facility MARKINGS and SIGNS?
-
8.28 - SHOP / No additional corrective actions required?
9.0 - Warehouse Areas
-
9.1 - WAREHOUSE / FIRE EXTINGUISHERS compliant?
-
9.2 - WAREHOUSE / EGRESS routes kept clear of obstacles?
-
9.3 - WAREHOUSE / ELECTRICAL SYSTEMS compliant?
-
9.4 - WAREHOUSE / MACHINE GUARDING compliant?
-
9.5 - WAREHOUSE / ORGANIZED and free of clutter and rubbish?
-
9.6 - WAREHOUSE / Free of SLIP or TRIP hazards?
-
9.7 - WAREHOUSE / RAILINGS and HOLE GUARDING compliant?
-
9.8 - WAREHOUSE / LADDERS compliant?
-
9.9 - WAREHOUSE / EXTENSION CORDS are OSHA compliant including GFCI where required?
-
9.10 - WAREHOUSE / STORAGE RACKS are secured and in good condition?
-
9.11 - WAREHOUSE / STORAGE RACKS and STORAGE AREAS are not unsafely loaded or stacked?
-
9.12 - WAREHOUSE / OVERHEAD STORAGE areas are marked with max load ratings?
-
9.13 - WAREHOUSE / CHEMICAL CONTAINERS are free of leaks and stored in approved areas?
-
9.14 - WAREHOUSE / Compliant with HAZCOM and DOT package marking requirements?
-
9.15 - WAREHOUSE / LOTO ENERGY ISOLATION POINTS properly marked?
-
9.16 - WAREHOUSE / Proper facility MARKINGS and SIGNS?
-
9.17 - WAREHOUSE / Adequate SECURITY at facility? (Ladders, doors, chemicals)
-
9.18 - WAREHOUSE / FORKLIFTS used and maintained in compliance with OSHA standards.
-
9.19 - WAREHOUSE / No additional corrective actions required?
10.0 - Facility General
-
10.1 - FACILITY GEN / FIRST AID adequate? (kit may be shared among multiple worksites within a facility if located in close proximity)
-
10.2 - FACILITY GEN / PERSONAL FALL PROTECTION EQUIPMENT properly stored and in safe condition?
-
10.3 - FACILITY GEN / RESPIRATORY PROTECTION EQUIPMENT properly stored and in safe condition?<br>
-
10.4 - FACILITY GEN / Proper SIGNAGE? (free of excessive fading and damage)
-
10.5 - FACILITY GEN / ORGANIZED and free of clutter and rubbish?
-
10.6 - FACILITY GEN / Free of SLIP and TRIP hazards?
-
10.7 - FACILITY GEN / WORKING and WALKING AREAS safe? (Impalement hazards, sharp edges, etc.)
-
10.8 - FACILITY GEN / RAILING and HOLE GUARDING compliant?
-
10.9 - FACILITY GEN / Adequate LIGHTING at facility?
-
10.10 - FACILITY GEN / RAILROAD SIDINGS in safe condition?
-
10.11 - FACILITY GEN / FALL PROTECTION SYSTEMS in safe condition? (Rail trolleys, cable systems, etc.)
-
10.12 - FACILITY GEN / BULK PROPANE STORAGE compliant with NFPA standards?
-
10.13 - FACILITY GEN / Other ELECTRICAL
-
10.14 - FACILITY GEN / Other GUARDING
-
10.15 - FACILITY GEN / Other LADDERS
-
10.16 - FACILITY GEN / No additional corrective action required?
11.0 - ROLLING STOCK & EQUIPMENT
-
11.1 - ROLLING STOCK & EQMT / Tractors, skid steers, loaders, and accessories compliant?
-
11.2 - ROLLING STOCK & EQMT / Portable augers and conveyors compliant?
-
11.3 - ROLLING STOCK & EQMT / Yard trucks and trailers in safe condition?
-
11.4 - ROLLING STOCK & EQMT / Commercial trucks and trailers maintained and inspected in compliance with DOT standards?
-
11.5 - ROLLING STOCK & EQMT / No additional corrective actions required?
Sign Off
-
Auditor's signature
-
On site representative