Unit Inspection Item and Description

  • Unit Type

  • Please specify

  • The manufacturer’s operations manual is stored on the unit<br>

  • Operating and emergency controls are in proper working condition (including emergency stop mechanism)

  • Functional platform drive controls are in proper working condition

  • Emergency lowering mechanism operates properly

  • Lower operating controls successfully override the upper controls

  • Both upper and lower controls are adequately protected from inadvertent operation

  • Control panel is clean and all buttons/switches are clearly visible

  • All switch and mechanical guards are in good condition and properly installed

  • All safety indicator lights work

  • All drive controls function properly and are accurately labeled

  • Motion alarms function properly

  • Safety decals are in place and readable

  • All guard rails are sound and in place, including basket chains

  • Work platform and extension slides are clean, dry, and clear of debris

  • Models with platform extensions: slides in and out freely with functioning safety locking pins

  • Inspect for defects, including cracked welds, fuel leaks, hydraulic leaks, damaged control cables or wire harness, etc.

  • Tires and wheels are in good condition with adequate air pressure if pneumatic

  • Braking devices are operating properly

  • Oil level/Hydraulic Oil Level/Fuel Level/Coolant Level is acceptable

  • Battery Charge is acceptable

  • Outriggers in place or functioning and associated alarms working

Safety Precautions to Consider/Have/Be Aware Of

  • Personal Protection in use (harness, lanyard, hardhat, etc.)

  • See manufacturer guidelines for use in windy conditions (always lower if lift begins to rock in the wind)

  • Floor/ground conditions: drop offs, holes, uneven surfaces, and sloped floors

  • Housekeeping: debris, floor obstructions, cords, construction materials and supplies

  • Location of electrical power cables or panels (keep minimum 10 ft. away) Contact Facilities Management Department for guidance on larger lines or wet conditions.

  • Look for chemical lines, gas lines, drain lines, and utilities

  • Location of overhead obstructions

  • DO NOT exceed load capacity

  • Watch for vehicular and pedestrian traffic (set up barricades if necessary)

Completion

  • If the Aerial Lift fails any part of this inspection, remove the key and report the problem to your supervisor. DO NOT operate. Submit completed checklist to your supervisor.

  • Inspected by: (name and signature)

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.