Title Page

  • Site conducted

  • Conducted on

  • Prepared by

  • Location

Safety Inspection

Switchboard Safety

  • Is there electrocution protection installed???

  • Minimum RCD requirement WA.png
  • Is there electrocution protection installed on ALL circuits?

  • What circuits require additional electrocution protection?

  • Are all circuits individually protected by an RCD?

  • Photo of switchboard

  • RCD (all circuits).png
  • Do the electrocution protection devices function correctly?

  • Are there any known recalled products installed?

  • Screen Shot 2020-11-04 at 9.24.44 am.png
  • Are there ceramic fuses installed?

  • Ceramic fuses info.png
  • Are all terminations safe and secure?

  • Are all circuit protection devices correctly sized?

  • Is there an appropriately rated main switch installed?

  • Main switch clause.png
  • What is the estimated mains cabling size?

  • Is the point of attachment in good condition?

  • Is there a metering fuse installed?

  • Is there an independent main earthing electrode installed?

  • Photo of main earthing electrode

  • Main earthing clause.png
  • Is there an equipotential bond installed?

  • Is the switchboard adequately bonded?

  • Is the MEN link installed and correctly sized?

  • Photo of MEN link

  • Is the switchboard structurally sound?

  • Are the cable entries adequately bushed?

  • Is the switchboard adequately fire sealed?

  • Fire sealant.png
  • Is the switchboard appropriately labelled?

  • SB Labelling.png
  • Could the switchboard contain asbestos based materials?

  • Asbestos risks .png
  • Is there any sub-standard cabling present inside the switchboard?

  • Sub standard cabling.png
  • Is there any sign of rodent damage?

  • Is there surge protection installed?

  • Surge protection.png

Smoke Alarm Safety

  • Are there smoke alarms installed?

  • Smoke alarm WA reg.png
  • Are the smoke alarms hardwired 240V?

  • Are the smoke alarms in date?

  • Are the correct number of smoke alarms install in the correct locations?

  • Smoke Alarm Locations.png
  • Do the smoke alarms operate under test conditions?

  • Smoke alarm testing.png
  • What type of smoke alarms are installed?

  • Photoelectric benefits.png
  • Are the smoke alarms interconnected?

  • Smoke alarm interconnects.png

Functionality Assessment

  • Are all light fittings functional?

  • List faulty fittings and locations

  • Photo of faulty fittings

  • Are all power socket outlets in good condition?

  • List damaged/faulty socket outlets and locations

  • Photo of damaged/faulty socket outlet

  • Are there halogen down lights installed?

  • Halogen Down light info.png
  • Thermal DL.jpg
  • Are the fixed cooking appliances functional?

  • Does the electric cooktop have a local isolation switch?

  • Cooktop local isolation - info.png

Air Conditioning

  • Is the AC unit functional?

  • Does the AC unit have a local isolator?

  • Condition of the filters?

  • Approx age of the AC unit

  • Photo of AC unit

Solar

  • Condition of the panels

  • Condition of the panel cables

  • Condition of the dektites and penetrations

  • Are the rooftop isolators inline with current regulations?

  • Are the DC isolators inline with current regulations?

  • Are the panel cables secured?

  • Is the inverter functioning correctly

  • Could the property benefit from an upgrade?

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.