Title Page
DATA REPORT - REVERSE OSMOSIS SYSTEM
-
AUDIT TITLE
-
Date
-
Customer #
-
Work Order #
-
Sales Order #
-
Part #
-
Model #
-
Serial #
-
GPD @77F
Data Report - Motor/Membranes:
-
Motor Model:
-
Motor Serial #:
-
HP:
- 1/3
- 1/2
- 3/4
- 1
- 1.5
- 2
- 2.5
- 3
- 3.5
- 5
- 7.5
- 10
- 15
- 20
- 25
- 30
- 50
- 75
- 100
- 125
-
Motor Stated Amp Draw:
-
Voltage:
-
Hertz:
-
Phase:
-
Wire Size AWG:
- 2
- 4
- 6
- 8
- 10
- 12
- 14
-
Pump Model #:
-
Pump Serial #:
-
Controller Serial #:
-
Pressure Gauges:
- Filter In
- Filter Out
- Pump Discharge
- Concentrate
-
Flow Meters:
- Product
- Concentrate
- Concentrate Recycle
-
Membrane Model:
- HF1
- HF4
- HF5
- HF6
- HR3
- NF3
- NF4
- CA1
- Evoqua Vantage LPR
- Evoqua Vantage XLPR
- XLE
- LCLE
- LCHR
- Other
-
Other:
-
Membrane Diameter:
-
Membrane Length:
Membrane Quantity/Serial Numbers:
-
Membrane Serials #:
Data Report Pressure Vessels:
-
Pressure Vessel Model:
-
Pressure Vessel Diameter:
-
Pressure Vessel Length:
- 14"
- 21"
- 40"
- 80"
- 120"
- 160"
- 200"
- 240"
- 280"
-
RO Array:
-
Date Started:
-
Verified By:
Preliminary Checks:
-
Motor Voltage Match To Order:
-
Membrane Element Quantity Match to Order:
-
TDS of Feedwater:
-
PPM:
-
Feedwater Temperature F - conversion factor:
-
Temperature F:
-
Feedwater Hardness GBG:
-
GBG:
-
Feedwater pH:
-
pH:
-
Chlorine Concentration mg/L:
-
mg/L:
-
System Flooded Before Start-up:
-
Flush system @ 50 psig:
-
Leak check @ 180 psig:
Flow / Rejection Rates:
-
Permeate (gpm):
-
Flow Meter Range:
-
Specification:
-
Test Flow Rates:
-
Concentrate (gpm):
-
Flow Meter Range:
-
Specification:
-
Test Flow Rates:
-
Concentrate Recycle (gpm):
-
Flow Meter Range:
-
Specification:
-
Test Flow Rates:
-
Feedwater Flow:
-
Specification:
-
Test Flow Rates:
-
% Recovery - Overall:
-
Permeate flow / Total Feed flow (Concentrate + Permeate) = % recovery
-
Specification:
-
Test Flow Rates:
-
Permeate Salt Rejection %:
-
Feed TDS – Permeate TDS = Sum / Feed TDS x 100 = % Rejection
-
Specification:
-
Rejection:
-
Permeate pH:
-
pH:
-
Blending:
-
Specification:
-
Test Flow Rates:
System Pressures:
-
Static System Pressure Check (15 min):
-
Feed Pressure:
-
psig:
-
Pump Discharge Pressure:
-
psig:
-
Low Pressure Switch psig:
-
psig:
-
Concentrate Pressure:
-
psig:
Controller Functions/Manual Switch:
-
Inlet Solenoid Opens and Closes:
-
Pump Starts After Delay:
-
Delay in Seconds:
-
Low Pressure Shutdown:
-
psig:
-
Automatic Low Pressure Reset:
-
Flush Cycle Function:
-
Autoflush Interval (Default Tank Full):
-
24 Hours
-
Autoflush Duration (Default 300 Sec):
-
Tank Full Shutdown:
-
High Pressure Shutdown:
-
Tank Full Pressure Switch Shutdown:
-
Pretreatment Lockout Function Shutdown:
-
TDS Audible Alarm Function:
-
Chemical Injection Outlet Voltage:
-
Output Voltage:
Controller Functions/Comparison of TDS Probe and Hand Held Meter:
-
Feed:
-
Hand Held Meter:
-
RO Controller Meter:
-
Product:
-
Hand Held Meter:
-
RO Controller Meter:
AMP Draw:
-
Specified Motor Amp Draw:
-
L.1:
-
L.2:
-
L.3:
-
System Overall Amp Draw Average:
Preservative Solution:
-
Solution Added:
Anti-Freezing Solution:
-
Solution Added:
Visual Inspection:
-
Paint/Exterior Finish:
-
Components Firmly Attached:
-
Piping is Square:
-
Electrical Fittings and Covers Secured:
-
Component Identification Labels:
-
Pre-Filter Configuration:
-
Flow Arrows on Vessels:
-
Feed/Permeate Concentrate Labels:
-
Electrical Connections Re-Tightened:
-
Caution Warning Labels Applied:
-
Branding Label Applied:
Notes:
-
Hand Held TDS Meter Serial #:
-
Notes:
Assembled By:
-
Assembler:
-
Signature:
-
Date:
Approved By:
-
QA/Test Technician:
-
Signature:
-
Date:
-
IMAGES