Title Page

  • Centre Name

  • Conducted on

  • Prepared by

  • Add signature

  • Location
  • Report reference number

  • Number of elements

  • The purpose of the inspection was an annual report and inspection defined by EN 12572-2017. To ensure the condition of the centre named above and it’s components guarantees continued compliance with the European Standard for Artificial Climbing Structures EN 12572:2017.

  • Hangfast recommends that the artificial climbing structure is inspected every 12 months.

Elements

    Element
  • A visual and tactile inspection was carried out to check security, integrity, overall condition and wear of the following areas. Where holds and fixings are concerned a selection were inspected to gain an overall view of the condition.

  • Element Name

  • Condition of wall Surface

  • Condition of holds and features

  • Security of wall pannels

  • Security of holds

  • Electronics

  • Condition of padding

  • Security of poles

  • Condition of ground anchors

  • Element consists of

  • Condition of tyres

  • Condition of Rope

  • Condition of pole/poles

  • Security of interlocking sections

  • Condition of panel surface

  • Condition of holds

  • Security of hold

  • Condition of structure

  • Condition and security of mountings

  • Condition of framework

  • Condition of slide surface

  • Condition of winch rope/wire

  • Condition of handle

  • Operation of winch and condition of control

  • Condition of structure

  • Condition of Ball structure

  • Condition of holds

  • Condition of visabel framework

  • Condition of blocks

  • Security of interlocking blocks

  • Condition of visabel framework

  • Condition of primary anchor point and maillon

  • Condition of back up anchor point, maillon and sling

  • Sling year of manufacture

  • Elements name

  • Elements name

  • see manual if required

  • Condition of Intervention Rope

  • Condition of Intervention rope anchor

  • Auto Belay present

  • Type of auto belay

  • Serial number

  • Date of next recert due

  • Condition of tape

  • Condition of Karabina

  • Condition of Swivel

  • Retraction speed

  • Braking and smooth operation

  • General appearance

  • Inappropriate noises

  • See manual for clarity if required

  • See manual for clarity if required

  • Serial number

  • Date of next recert

  • Counter reading

  • Condition of Rope

  • Condition of carabiner

  • Braking operation

  • Retraction speed

  • General appearance

  • Inappropriate noises

  • See manual for clarity if required

  • Condition of Totem pole structure

  • Condition of holds

  • Type of upper anchors

  • Condition of bar/beam

  • Security of bar/beam

  • Conditon of wires

  • Condition and tension of bottle screws

  • Condition of anchor points

  • Condition of ground anchors

  • Condition of holds

  • Security of holds

  • Condition of perspex panels

  • Security of perspex panels

  • Condition of framework

  • Condition of structure

  • Condition of Punchbag/Trapeze

  • Punchbag/Trapeze position adjustment system

  • Belay lowering device installed?

  • Condition of belay lowering system

  • Condition of secondary autobelay device

  • Auto Belay present

  • Type of auto belay

  • Serial number

  • Date of next recert due

  • Condition of tape

  • Condition of Karabina

  • Condition of Swivel

  • Retraction speed

  • Braking and smooth operation

  • General appearance

  • Inappropriate noises

  • See manual for clarity if required

  • See manual for clarity if required

  • Serial number

  • Date of next recert

  • Counter reading

  • Condition of Rope

  • Condition of carabiner

  • Braking operation

  • Retraction speed

  • General appearance

  • Inappropriate noises

  • See manual for clarity if required

  • Condition of primary anchor point and maillon

  • Condition of back up anchor point, maillon and sling

  • Sling year of manufacture

  • Elements Name

  • Element name

  • see manual if required

  • Condition of Intervention Rope

  • Condition of Intervention rope anchor

  • Auto Belay present

  • Type of auto belay

  • Serial number

  • Date of next recert due

  • Condition of tape

  • Condition of Karabina

  • Condition of Swivel

  • Retraction speed

  • Braking and smooth operation

  • General appearance

  • Inappropriate noises

  • See manual for clarity if required

  • See manual for clarity if required

  • Serial number

  • Date of next recert

  • Counter reading

  • Condition of Rope

  • Condition of carabiner

  • Braking operation

  • Retraction speed

  • General appearance

  • Inappropriate noises

  • See manual for clarity if required

  • Description/Name of wall

Rear structure inspection

  • A visual and tactile inspection of the frame work and fixing points was carried out to look for loose fitting points, damaged joints and stressed areas.

  • Sub-structure type

  • Condition of steel frame work

  • Security of bolted joints

  • Condition of welded joints

  • Condition of wood frame work

  • Security of wood frame work

  • Sub Strucre mounting method

  • Condition of steel frame work

  • Security of bolted joints

  • Condition of brick work

  • Security of bolted joints

  • Condition of steel frame work

  • Condition of welded joints

  • Conditon of wires

  • Condition and tension of bottle screws

  • Condition of anchor points

  • Condition of ground anchors

  • Condition of steel frame work

  • Security of bolted joints

  • Condition of welded joints

  • A visual inspection of a selection of the fixing points was conducted to look for damaged threads and any signs of the fixings failing, pulling through the wall or becoming fouled.

  • Bolt on holds and features fixings

Saftey Surfaces

  • Saftey Surface type

  • The climbing area has rubber crumb matting laid below the climbing areas. These were visually inspected.

  • Condition of mating

  • Condition of joints

  • Floor cleanliness and debris

  • The climbing area has wet pour rubber crumb flooring laid below the climbing areas. These were visually inspected.

  • Condition of mating

  • Floor cleanliness and debris

  • The climbing area has gymnastics matting laid below the climbing areas. These were visually inspected.

  • Condition of mats

  • Security and positioning of mats

  • Pentagon condition

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.