Administrative Job Site Requirements
-
Active construction area clearly demarcated and safety access signage posted?
-
Emergency contact information, egress routes and evacuation muster points posted?
-
Area urgent and emergency healthcare facilities posted?
-
Daily SPA accurately reflects work, means/ methods, and precautions?
-
Daily SPA reviewed and signed by Superintendent or representative?
-
Daily SPA readily accessible in the field?
-
Daily SPA completed and signed by contractor Competent Person and contractors performing the work?
-
Daily SPAs are closed and end of day affirmation signed?
-
-
JSAs readily accessible in the field?
-
Are all JSAs reviewed and approved by EHS?
-
Name of JSA(s) audited? Audit 1 JSA per active contractor.
-
Does the JSA adequately capture the scope of work?
-
Are JSAs signed by the contractors working on the job?
-
Name of JSA reviewed? Review 1 JSA per active contractor.
-
Are JSA's signed by and approved by EHS?
-
Are JSA's signed by the contractors working on the job?
-
Does the JSA adequately capture the scope of work?
-
-
If applicable, are required personnel OSHA 10/30 Hour trained for Foreman/Supervisors?
-
Are construction signs posted?
COVID-19 Mitigation
-
COVID-19 Management Plan for project/ site approved and current?
-
Client COVID-19 screening process implemented for contractors?
-
C2 Daily Pandemic Self-Assessment completed by all contractors and visitors?
-
COVID-19 signage posted clearly?
-
Sanitation facilities and hand washing facilities available and stocked?
-
Routine (3-4 times daily) touchpoint sanitization being conducted?
-
All workers and visitors wearing fabric or surgical mask face-covering? Bandanas and neck gaiters prohibited.
-
All workers maintaining 6' distance at all times?
-
Does workers have a COVID-19 Pre-Task Safety Planning in place for activities which are infeasible to complete while maintaining 6' of distancing at all times?
-
Break and lunch accommodations made to maintain 6' distance?
-
Tools not being shared or being sanitized between users?
Housekeeping
-
Are materials stored properly?
-
Is trash being centered piled and collected routinely throughout work day?
-
Has construction dumpster been designated and located for the project?
-
Is the dumpster appropriately sized and properly managed for pick ups?
-
Are the walking and working surfaces clear, clean, trip hazards eliminated?
PPE
-
Are hard hats, safety glasses, cut resistant gloves, vests (as required), and steel or composite toe footwear being worn by craft and management?
-
Is the work being performed exceeding 85db? Is proper hearing protection in place?
-
Is there PPE available for visitors?
-
Is there any additional PPE being worn? Has it been identified in the JSA?
-
Are all respiratory users qualified or have signed the "voluntary use" sign off sheet on job site?
Fall Protection
-
Is work being preformed greater than 6ft?
-
Has the Working at Heights Permit been completed?
-
Are flag lines, weighted base and rail, and other relevant fall restraint systems properly utilized?
-
Has the proper PFAS been identified and inspected for the work?
-
Are anchor points engineered?
Fire Safety and Emergency.
-
Are there a proper fire extinguishers available with in 50 feet of work ?
-
Are the sprinkler heads & fire protection systems unobstructed ( sprinkler heads clear by 18'' or greater)?
-
Is the Fire Extinguisher Inspection current?
-
Is there a trained fire watch on duty during Hot Work?
-
Are flammable and combustible materials stored properly? ( SDS at point of use )
-
Are stairwells clear of combustible or flammable materials?
-
Is there a First Aid Kit and eye wash station on job site?
General Safety
-
Are there any outstanding safety violations that have been identified during the audit?
-
Are there any outstanding safety successes that have been identified during the audit?
-
All containers labeled? ( HAZCOM )
-
Is temporary lighting provided as needed? <br>(29 CFR 1926.56(a) table D-3)
-
Is equipment guarding in place as per manufacturers instructions?
-
Are tools and equipment inspected and in good condition prior to use?
-
Is there a spill kit on the job site?<br>
Ladders/ Stairs/ Scaffolds.
-
Are Stairs provided where there is a change in elevation >19'' ( EU >0.5m), and secured?
-
Are Stairs greater than 4 risers all equipped with a hand rail?
-
Is scaffolding in use, built by a qualified competent erector, built correctly, secured, tagged correctly and inspected daily? ( check mudsills or locked wheels)
-
Does the scaffolding have safe access and egress for workers?
-
Are Holes/penetrations protected with secured covers labeled "HOLE" or barricaded?
-
Is the scaffolding protected for use by unauthorized persons, is there a swing gate which can be locked when no one is working?
-
Are ladders being used safely? No one working above the 2 rung? Tied off when required? Etc...
-
Are Ladders in good condition? Labels, rings, feet...
-
Are Ladders being stored correctly?
-
Are Ladders in being used as intended?
-
Are Extension Ladders being used safely with proper pitch, ladder secured and a 36 inch overhang?
-
Are platforms protected by handrail, midrail and toe board?
Welding/ Cutting / Brazing
-
Has the hot work permit been reviewed and completed?
-
Have all combustibles been removed 35ft or covered? ( flammables removed)
-
Is torch cutting being performed with proper PPE and area prepped?
-
Are compressed gas cylinders secured and capped when not in use?
-
Are Torches, hoses, gauges / regulators in good conditions and equipped with flash back preventers?
Crane Lifting / Rigging.
-
Has the lift plan and permit been completed and reviewed with all affected personnel?
-
Are there trained signal men in "line of sight" of operator or other means of communication with operator?
-
Has the qualified rigger inspected all lifting equipment prior to use?
-
Has the crane been properly barricaded?
-
Have all the areas within the swing radius been notified, with proper signage , barricaded with danger tape and evacuated?
-
Are tag lines being used to control the load?
-
Has the crane inspections been completed and documented?
Excavation/ Confined Space.
-
Verify One Call ticket.
-
Utility mark out is clear and being refreshed by the excavation contractor?
-
Is the excavation lay out in White?
-
Has the excavation permit been reviewed and completed?
-
Has utility location taken place? 8 feet outside the permiter of the excavation?<br>Verify report
-
Are the trenches/ excavations sloped properly or shored and barricaded?
-
Is trench/ excavation greater than 4ft?
-
Is body harness being worn?
-
Are there proper egress in place, ladders no more than 25ft apart?
-
Is this a HAZWOPER site and if yes is training verified?
-
Has a weather event occurred since initial evaluation from a competent person?
-
Is confined space permit required and has the been permit been reviewed and completed?
-
Has the confined space attendant properly maintained the access log?
-
On site rescue team?
-
Are the Confined space personnel properly trained?
-
Verify Confined Space training?
-
Atmospheric testing at 3 levels? <br>Example: Top Middle Bottom
Motorized Equipment. ( [PIT's, lifts)
-
Is there motorized Equipment being use?
-
Has the proper inspection been performed and documented?
-
Do the operators have the proper training for the equipment being used?
-
Are seat belts used by all operators?
-
Do the motorized vehicles have proper back up alarm?
-
Is the chain or gate closed on Scissor Lift?
-
Are flaggers in place where needed?
-
Is Scissor Lift being used safely? Feet on surface not using mid rail or toe board to stand on not leaning outside lift?
-
For boom Lift is PPE correct?
-
Is the rollover protection in place and maintained?
-
Has field modification been made without manufacturers written approval?
Electrical Safety.
-
Is there a energized electrical permit in place?
-
Has the energized permit been reviewed and completed?
-
Are all electrical tools and cords free of chemicals, flammables and water?
-
Are extension/power cords creating a trip hazard?
-
Are cords in good condition, no cuts or repairs w/ tape?
-
Is the Proper Lockout/Tagout in place where needed?
-
Is there a 3ft clear distance around electrical panel?
-
Are GFCI's being used and closest to the power source?
-
Are the required permits completed and posted?
Environmental
-
Have all proper barricades been put in place to minimize cross contamination?
-
Are the Concrete truck washout procedures being followed?
-
Is the waste handling and disposal of hazardous waste being executed properly?
-
Is secondary containment in place where needed?
-
Is Threading Machine catch box in place?
-
Are Storm sewers protected?
-
Are chemicals at the job site being stored safely and are they labeled correctly?
-
Is there proper ventilation in place for stored chemicals?
-
Are the SDS provided at job site? ( point of use )
-
Are personnel trained in the chemicals they are handling?
Corrective actions and supplemental comments.
stakeholders
-
PM or CM
-
Auditor.