Information

  • Audit Title

  • Document No.

  • Client / Site

  • Conducted on

  • Prepared by

  • Location
  • Personnel

PPE

  • Are PPE requirements sufficient?<br> -Should gloves be required?<br> -Should a face shield be required?

  • Is PPE supplied adequate for the task?<br> -Previous injuries when using current PPE? Why?<br> -PPE being replaced excessively? (e.g. Burn holes, soaked with liquid chemicals, etc.)

  • Is PPE being worn properly? <br> -Ear plugs completely inserted into ears<br> -Safety glasses fit properly and pass fit test (gaps no larger than width of finger)<br> -Gloves being worn when handling materials that are sharp, hot, etc.

Tools/Machinery/Equipment

  • Are all tools in good working condition?<br> -Held together with tape?<br> -Excessive noise/vibration?<br> -Requires excessive manual manipulation?

  • All existing guarding in place?<br> -Guards laying on the floor?<br> -Bolts/Screws missing from fixed guarding?<br> -Guards shifted causing open point of operation?

  • Machinery working properly and not causing regular manual manipulation?<br> -Frequent breakdowns causing manual work?<br> -Machinery producing excessive noise/vibration due to disrepair?

Hazard Communication

  • Employees know how to find MSDS and understand the hazards of the chemicals they work with. (Interview >=2 employees)

  • Ventilation adequate for the airborne health hazards?<br> -Industrial hygiene sampling results on file?<br> -Employee complaints about "fumes" or "nausea/dizziness"

  • Chemicals are stored in proper containers and labeled properly?<br> -Secondary containers that are not in control of current shift labeled with HMIS label or equivalent?<br> -Labels legible and accurately indicates the chemical that is inside the container?<br>Chemicals stored properly?<br> -Flammable materials not in use stored in proper cabinet/safety container?<br> -Incompatible materials stored away from each other?

  • Incidental spills cleaned up immediately?<br> -No evidence of spills being left?<br> -Chemicals being tracked on employees' shoes and/or mobile equipment?

Walking/Working Surfaces and Fall Protection

  • Proper labels in place and legible?<br> -Portable ladders and stairways require labeling indicating weight limits.

  • Floors and work platforms free of excessive debris and clutter?<br> -Excessive oil, trash, manufacturing byproducts, etc. in the work are?<br> -No items stored on stairs?

  • Handrails secure and free of excessive defects?<br> -Heavily damaged handrails that require replacement? Loose? Broken welds? Bent handrails and/or toe boards?<br> -Handrails do not contain excessive oil/grease?

  • Fall protection equipment available for working at heights greater than 3 meters from the working surface below it where fall prevention is not available?

Emergency Response/Fire Protection

  • Fire extinguishers inspected monthly and unblocked?

  • Employees aware of emergency procedures and where assembly areas are? (Interview >=2 employees)

  • Eyewash/Safety Shower stations inspected and unblocked?

  • Spill kits are available where needed and are equipped/inspected as required?

  • Sufficient emergency equipment installed in the area?<br> -Fire extinguishers, eyewash, safety shower, spill kits, alarm pull stations, etc.

Mobile Equipment

  • Equipment inspected per inspection frequency requirements?

  • Operators using horns and warning devices where required?

  • No passengers on equipment designed for operators only?

Electrical Hazards/Arc Flash

  • High voltage signs in place and visible?

  • Electrical cabinets closed and in good repair?<br> -Do the cabinets close securely?<br> -Knock-outs all in place?<br> -Debris/Tools stored on top of electrical cabinets?<br> -Nothing within 36 inches of the front of the cabinet?<br> -Large dents in the housing/door?

  • Arc flash signage in place?<br> -Indicates arc flash category?

Hazardous Energy Control (Lockout/Tagout)

  • Employees expected to conduct lockout trained and equipped properly?<br> -Employees understand their role and requirements?<br> -Employees have locks available if needed?

  • Employees locked out during a change over and/or other tasks that require lockout?<br> -All employees who are working on the equipment have their own lock affixed to the proper energy source(s)?<br> -Lockout was verified, stored energy was dissipated and equipment will not operate?

  • Energy control procedures exist for all equipment in the area and employees know where to find them?

Crane/Hoist Safety

  • Are employees working under suspended loads?

  • Are cranes working within their operating limits?<br> -Capacity not exceeded?<br> -Upper limit switch not used as a stop?

General Safety and Housekeeping

  • Trash, debris, and equipment not left laying around?

  • Equipment free of excessive dust, oil and/or soot?

  • Floor surfaces covered in oil/dust covering the painted surface?

  • General tripping hazards due to housekeeping, equipment layout, and/or workstation design?

Signature and Finalization

  • I have completed this assessment to the best of my knowledge. This audit is not intended to identify all safety and health hazards, but to identify all visible/known hazards as of the date printed on the completed assessment. assessment.

  • Select date

  • General Comments

  • Overall Safety Score

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.