Title Page

  • Tram No:

  • Prepared by

  • Date

  • Depot conducted

Pre-check modules

FAT Quality Checklist - Refer to "Functional checks at power on" document

Cab-2 I/O and ADAMS Device check

  • End 2 - Ignition key OFF<br><br>Verify the following functions:<br> 47-K04 - Relay Light is "ON"<br> ADAMS DI3 is less than 1V

  • End 2 - Ignition Key ON<br><br>Verify the following functions:<br> 47-K03 - Relay Light "OFF"<br> 47-K04 - Relay Light "OFF"<br> ADAMS DI2 and DI3 are between 7V to 9V

Drivers Cabin - Camera Select End 2, Press camera select button (right button - drivers arm rest)

  • D1 - Does camera cycle through 1-4 then back to 1?<br> D2 - Does camera cycle through 1-6 then back to 1?

  • Does the camera numbers match the door numbers?

  • Are the video image's crisp, color is true, and no pixilation's or dead pixels?

End 2 - Genetec 2 Monitor [Driver Monitor]

  • End 2 Cabinet - Locate wire E22811.04 in Terminal 58 and remove it When wire disconnected, does the relay light go off, and the Genetec display go to the Color background?

  • End 2 Cabinet - Connect wire E22811.04 in Terminal 58<br><br>When wire is connected, does the display goes back to the CCTV footage?

End 2 - Door Test

Press Front Door Open

  • Confirm the following functions:<br>47-K05 - light is off<br>ADAMS DI4 voltage between - 7V to 9V

Close all Doors

  • Does Relay Light 47-K05 turn on when ADAMS DI4 is less than 1V, ONLY when all doors are closed.

End 1 - Driver's Display

  • Go to end 1, turn the ignition key on End 1<br><br>Verify the following test<br> 1. Video is Crisp, color is relatively true, no pixilation's or dead pixels<br> 2. Relay light illuminated on 47-K03, ADAMS DI2 is less than 1V

Camera Disconnection Test

  • Disconnect any camera<br><br>1. Relay 47-K07 light goes on 30s - 1min after disconnection.<br>2. Wait 30s to 1 min, check the Klipstation alarms (drivers right hand side console). <br>3. Press the camera select button<br><br>Check the disconnected camera comes up with no CCTV footage

OCMS Test

  • Ask OCMS person to generate a computer fault<br><br>Wait 30s - 1min, check Klipstation alarms to verify fault

OCMS - GPS/ 5G Testing

  • Ask OCMS person to check wireless connections<br><br>Test<br> 5G is connected and GPS shows location at current location/ depot<br> Name of the tram in Genetec matches actual tram<br>

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.