Title Page
-
Inspection ID (FORM NUMBER GENERATES AUTOMATICALLY)
- CB 148 Coronation Square
- CB297/ Redrow Block x
- woolwich subs
- CB304 Lovell /stevenage
- CB217 West Byfleet
- CB267 BLOCK N41
- CB306 MORRIS WALK SOUTH 5A
- CB306
- Woolwich north
- lovell
-
Project name
- CB 148 Coronation Square
- CB297/ Redrow Block x
- woolwich subs
- CB304 Lovell /stevenage
- CB217 West Byfleet
- CB267 BLOCK N41
- CB306 MORRIS WALK SOUTH 5A
- CB306
- Woolwich north
- lovell
-
client
- CB 148 Coronation Square
- CB297/ Redrow Block x
- woolwich subs
- CB304 Lovell /stevenage
- CB217 West Byfleet
- CB267 BLOCK N41
- CB306 MORRIS WALK SOUTH 5A
- CB306
- Woolwich north
- lovell
-
job number
- CB 148 Coronation Square
- CB297/ Redrow Block x
- woolwich subs
- CB304 Lovell /stevenage
- CB217 West Byfleet
- CB267 BLOCK N41
- CB306 MORRIS WALK SOUTH 5A
- CB306
- Woolwich north
- lovell
-
Area Being Inspected (Please Add Area, Floor & Lift Number ) (E.g - Block A, GF, Subs or Block B, FF, 1st Lift). It is important to be clear on this so we can track them easily at a later date
-
Elevation/s
- North
- South
- East
- West
- North/East
- North/West
- South/West
- South/East
-
Conducted on
-
Prepared by
-
Location
Setting Out
-
The setting out dimensions have been completed as per the architechtural details?
-
Explanation for N/A?
-
Datum value has been cross checked with control points?
-
Explanation for N/A?
-
Masonry stengths have been cross checked with structural engineers details?
-
Explanation for N/A?
In Progress Checks
-
Mortar is correct mix? Please specify ratio in notes
-
Explanation for N/A?
-
Cavity fill completed as specified?
-
Explanation for N/A?
-
Gauging and bond are correct?
-
Explanation for N/A?
-
Cavity insulation correct type and size?
-
Explanation for N/A?
-
Cavity insulation is fixed correctly, close butted, clean and free from mortar?
-
Explanation for N/A?
-
Cavity width is as specified, cavity and ties are free from mortar and debris?
-
Explanation for N/A?
Structural
-
Movement control joints are formed, as designed?
-
Explanation for N/A?
-
Cavity ties are within specification, design and correct type?
-
Explanation for N/A?
-
Wall head restraints Installed as per detailed design?
-
Walls are tied in to cross walls or steel?
-
Wall ties are bedded at least 50mm into masonry leaves and are level or slope downwards to the outer leaf and drip point downwards /proprietary wall ties are laid the correct way up?
-
Explanation for N/A?
-
Wall ties are staggered in alternate courses and spaced in accordance with the design?
-
Explanation for N/A?
-
Extra ties are provided at jambs and reveals?
-
Explanation for N/A?
-
Extra ties are provided at openings, slab edges, movement joints and wall heads in accordance with the design?
-
Explanation for N/A?
-
Lintels, bedded correctly with 150mm minimum bearing?
-
Joint reinforcement (where applicable) is correct type?
-
Explanation for N/A?
-
Joint reinforcement bar are at least 20mm from external mortar face and at least 12mm from internal building faces?
-
Wind posts have been installed as per detailed design?
-
Masonry support angle has been torque tested and complies with the manufacturers installation instructions?
-
Designed overhang / embedment achieved on masonry support angle?
-
Explanation for N/A?
-
Padstones are installed as per the structral engineers specification?
Passive Fire Protection
-
Cavity barriers are installed as per the manufactures installation instructions?
-
Explanation for N/A?
-
Cavity barriers are installed to the fire strategies provided?
-
Explanation for N/A?
-
All cavity barriers have been accounted for as per the Chine FQA Schedule & photo evidence recorded?
-
Explanation for N/A?
-
Chine FQA checks are being completed and signed by the client?
-
Explanation for N/A?
DPC's/Cavity Trays
-
DPC's are within specification, design and correct type?
-
Explanation for N/A?
-
DPC is flush with face or projecting, laps at least 100mm and sealed?
-
Explanation for N/A?
-
Cavity trays are installed; over cavity bridges (e.g. over doors, window openings, ducts and horizontal cavity barriers), at roof abutments, to exclude soil gas eg. Radon methane etc. Jambs in cavity walls?
-
Explanation for N/A?
-
Cavity trays have stop ends?
-
Explanation for N/A?
-
Weep vents are installed as design?
-
Explanation for N/A?
Tolerances
-
Position in plan of any point in relation to the building reference line and/or point at the same level is within 10mm?
-
Explanation for N/A?
-
Straightness in any 5m length +/- 5mm?
-
Explanation for N/A?
-
Verticality up to 3m height +/- 10mm?
-
Explanation for N/A?
-
Verticality up to 7m height +/- 14mm?
-
Explanation for N/A?
-
Overall thickness of walls +/- 10m?
-
Explanation for N/A?
-
Level of bed joints up to 5m for brickwork +/- 11mm?
-
Explanation for N/A?
-
Level of bed joints up to 5m for blockwork +/- 13mm?
-
Explanation for N/A?
-
Window and Door openings within architects tollerances in specification?
-
Explanation for N/A?
Protection/Lift Complete
-
The masonry is correctly pointed and finished?
-
Pin holes/clamp holes filled in?
-
Explanation for N/A?
-
Panels are clean?
-
Impervious protection against rain and frost is provided?
-
Explanation for N/A?
-
Masonry is protected adjacent to scaffold boards?
-
Explanation for N/A?
-
Area is cleaned on completion of work?
-
Explanation for N/A?
QA Sign Off - Please Sign Within 72 Hours
-
Signed - Chine Brickwork
-
Client Name
-
Signed by
-
Signature
-
Date