Information

  • Add media

  • Location
  • Owner:

  • Emergency Contact Number:

  • Conducted on

Site Requirements

  • The authority having jurisdiction shall require a certificate or other evidence of acceptance by an organization or laboratory of recognized standing or manufacturer verifying that the tent fabric material has been treated with a flame resistant material. (11 CSR 40-3.010.7.B.1)

  • No hay, straw, shavings, or similar combustible materials that have not been treated to make them flame retardant shall be permitted within any seasonal retail sales location. Vegetation or grass within the location should also be treated with an approved flame retardant treatment. (11 CSR 40-3.010.7.B.2)

  • The area located within 30-feet of a retail sales location shall be kept free of accumulated dry grass, dry brush, and combustible debris. (11 CSR 40-3.010.7.B.3)

  • Fireworks shall not be displayed or stored behind glass through which direct sunlight will shine on the fireworks except for where the fireworks are in their original package. (11 CSR 40-3.010.7.B.4)

  • Fireworks are not within public reach when attendant is not on duty. (11 CSR 40-3.010.7.B.5)

  • No motor vehicle shall be parked within 10-feet of a seasonal retail sales location. (11 CSR 40-3.010.7.E.1)

  • No trailer used for storage of consumer fireworks shall be parked within 10 feet of a seasonal retail sales location. (11 CSR 40-3.010.7.E.2)

  • Temporary seasonal retail sales stands and tent side walls shall not be located within 20 feet of another building, another seasonal retail sales location, cooking equipment, & generators. (11 CSR 40-3.010.7.E.3 & 5)

  • Seasonal retail sales locations shall not be located within 100 feet of gasoline pumps, gasoline filling stations, gasoline bulk stations, any building in which gasoline or volatile liquids are sold in quantities in excess of 1 gallon, compressed natural gas dispensing facilities, retail propane dispensing stations, above ground storage tanks for flammable or combustible liquids, & any type of open flame cooking equipment. (Municipal Code 220.040)

Egress

Egress

  • All means of egress from any temporary seasonal retail sales tent or stand shall remain clear and free of obstructions. (11 CSR 40-3.010.7.F.1)

  • A minimum of 2 remote means of egress shall be located in a seasonal retail sales location. (11 CSR 40-3.010.7.F.2)

  • Exits provided for temporary seasonal retail sales stands shall be arranged so that the maximum egress travel distance does not exceed 35 feet. (11 CSR 40-3.010.7.F.3)

  • Exits provided for seasonal retail tents shall be arranged so that the maximum egress travel distance measured from the most remote point to an exit along the natural and unobstructed path of egress travel does not exceed 75 feet. (11 CSR 40-3.010.7.F.4)

  • Aisles within a temporary seasonal retail sales tent, where the interior is accessible to the public, the minimum clear width shall be permitted to be not less than 48 inches. (11 CSR 40-3.010.7.F.5)

  • Aisles within a temporary seasonal retail sales stand, where the interior is not accessible to the public, the minimum clear width shall be permitted to be not less than 28 inches. (11 CSR 40-3.010.7.F.6)

  • The required width of aisles shall be maintained unobstructed at all times the facility is occupied by the public. (111 CSR 40-3.010.7.F.7)

  • Dead end aisles shall be prohibited. (11 CSR 40-3.010.7.F.8)

  • Exit openings from seasonal retail sales tents shall be not less than forty-four inches (44") in width. (11 CSR 40-3.010.7.F.9)

  • Egress doors in temporary seasonal retail sales stands where the interior is not accessible to the public shall be permitted to be not less than twenty-eight inches (28") in width. (11 CSR 40-3.010.7.F.10)<br>

  • Egress doors in temporary seasonal retail sales stands where the interior is accessible to the public shall be permitted to be not less than thirty-six inches (36") in width. (11 CSR 40-3.010.7.F.11)

  • No fireworks shall be displayed for sale or stored within two feet (2') of any public exit, or private entrance or exit in an enclosed building. (11 CSR 40-3.010.7.F.12)

Emergency Lighting and Exit Signs

  • Exit signs shall be required to be self-luminous or internally or externally illuminated.<br>Exit signs shall not be required to be illuminated in tents or stands that are not open for business after dusk or in temporary seasonal retail sales stands where the interior is not accessible to the public. (11 CSR 40-3.010.7.G.1&2)

  • Emergency lighting shall not be required in tents or stands that are not open for business after dusk or for temporary seasonal retail sales stands where the interior is not accessible to the public.<br>Emergency lighting shall be required in seasonal retail sales locations when the retail sales area is eight hundred (800) square feet or greater. (11 CSR 40-3.010.7.G.3&4)

Signage

Fireworks Discharge

  • Fireworks shall not be ignited, discharged, or otherwise used within 100 feet of any location where fireworks are stored, sold, or offered for sale. (11 CSR 40-3.010.7.C.1)

  • At least one (1) sign that reads as follows, in letters at least four inches (4") high on a contrasting background, shall be conspicuously posted on all sides of seasonal retail sales locations: <br>"NO FIREWORKS DISCHARGE WITHIN 100 FEET" (11 CSR 40-3.010.7.C.2)

undefined

  • Smoking shall not be permitted inside or within twenty-five feet (25') of the seasonal retail sales area. (11 CSR 40-3.010.7.D.1)

  • One (1) or more signs reading, "FIREWORKS NO SMOKING" shall be displayed on all sides of seasonal retail sales locations in letters not less than four inches (4") in height on a contrasting background. (11 CSR 40-3.010.7.D.2)

Electrical

Electrical

  • The electrical system and equipment shall be isolated from the public by proper elevation or guarding, and all electrical fuses and switches shall be enclosed in approved enclosures. (11 CSR 40-3.010.7.H.1)

  • Electrical cables, including extension cords on the ground in areas traversed by the public shall be placed in trenches or protected by approved covers. (11 CSR 40-3.010.7.H.2)

  • All extension cords shall be a minimum fourteen (14) gauge and multi-outlet power strips shall be UL approved and of the grounding type. (11 CSR 40-3.010.7.H.3)

  • All multi-outlet power strips shall be UL approved and of the type with a circuit breaker for overload protection. (11 CSR 40-3.010.7.H.4)

  • All electrical wiring, equipment, and devices shall be UL approved, installed and maintained to prevent electrical hazards. (11 CSR 40-3.010.7.H.5)

  • All electrical lighting shall be UL approved, mounted and installed in a safe manner. (11 CSR 40-3.010.7.H.6)

  • Branch circuits for receptacles, lighting and other uses shall be protected by ground fault circuit interrupters if susceptible to water exposure. (11 CSR 40-3.010.7.H.7)

  • The power distribution panel shall be properly grounded with a minimum #6 solid copper wire connected to a copper clad ground rod. The ground wire must be connected to the ground rod using a UL approved ground rod clamp with the clamp being visible. (11 CSR 40-3.010.7.H.8)

Extinguishers

Fire Extinguishers

  • Every seasonal retail sales location shall have not less than two (2) portable fire extinguishers with a minimum 2A rating, at least one (1) of which shall be a pressurized water type. (11 CSR 40-3.010.7.A.1) Temporary seasonal retail sales locations less than two hundred (200) square feet in area shall be required to have at least one (1) portable fire extinguisher with a minimum 2A rating. (11 CSR 40-3.010.7.A.2)

  • Are fire extinguishers fully charged?

  • All fire extinguishers shall be inspected annually by a fire extinguisher company and have documentation to this effect attached to them. (11 CSR 40-3.010.7.A.4)

  • Last Inspection Date:

  • The maximum travel distance to a fire extinguisher in any seasonal retail sales location shall be no greater than thirty-five feet (35'). (11 CSR 40-3.010.7.A.3)

  • All fire extinguishers shall be located in an accessible location to the staff. (11 CSR 40-3.010.7.A.5)

  • Employees shall be trained to operate fire-extinguishing equipment and shall be required to exhibit their skill when requested by the authority having jurisdiction. (11 CSR 40-3.010.7.A.6)

Fire Rated Materials and Construction Elements

  • The retail sales of pest control devices, including their related storage and display shall be prohibited. (11 CSR 40-3.010.7.I.1)

  • No electronic pest control device(s) shall be located inside a seasonal retail sales location. (11 CSR 40-3.010.7.I.2)

  • The consumption or possession of alcoholic beverages in any seasonal retail sales location is prohibited during business hours. (11 CSR 40-3.010.7.I.3)

  • Any person selling fireworks shall not knowingly sell consumer fireworks to any person who is obviously under the influence of alcohol or drugs. (11 CSR 40-3.010.7.I.4)

  • Proximate and display fireworks shall not be allowed to be sold with consumer fireworks. (11 CSR 40-3.010.7.I.5)

Miscellaneous

Additional Information

  • Inspection pass for business license?

  • Follow-up Inspection Date:

  • Monett Fire Department Inspector

  • 211 5th, St. Monett, MO 65708 Office: (417)635-3525 Cell: (417)737-0263 jowens@cityofmonett.com

  • Business representative

  • In accordance with The City of Monett Municipal Code, Section 205.110, Fire and Life Safety Inspections are conducted to the "International Fire Code 2006 edition", including Appendix Chapters and referenced codes and standards. Persons who shall violate a provision of this code or shall fail to comply with any of the requirements thereof or who shall erect, install, alter, repair or do work in violation of the approved construction documents or directive of the fire code official, or of a permit or certificate used under provision of this code, shall be guilty of a ordinance violation, punishable by a fine of not more than $500.00 or by imprisonment not exceeding 100 days, or both such fine and imprisonment. Each day that a violation continues after due notice has been served shall be deemed a separate offense.

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.