EXTERIOR

  • Exterior Siding/ Soffit/fascia/ roofing sound workmanlike conditions ~ no holes, peeling paint, loose siding

  • Gutters and downspout extensions in place?

  • Storms/ screen units provided on all uninsulated windows?

  • Screen Units provided on all insulated windows?

  • Wood windows and trims painted in workmanlike manner?

  • House numbers provided and visible from street?

  • Exterior Lighting Provided at Exit Doors?

  • Handrails to Stairs with 4 or more risers are no less that 34-38" high

  • Railing with maximum of 4" spacing provided at decks, porches and sides of stairways if greater that 30" from Grade

  • Exterior sidewalks in good condition - no surface deterioration, cracks, vertical or horizontal gaps of greater that 2"

  • Driveway in sound condition?

  • Exterior Electrical service wiring secured to home?

  • Electrical or low voltage wiring is securely attached to the siding?

  • Tree limbs are trimmed away from the roof, siding and foundation

  • Grade slopes away from structure to prevent ponding along the foundation wall.

  • Masonry / Chimney maintained in sound condition

  • Accessory Structures (fences, sheds, decks, carports, garages etc.) in sound condition and free from damage and deteriorated paint.

  • Property free from debris, trash, garbage, rubbish, imoperable and unregistered vehicles

  • Interior Unit 1
  • Verify smoke detector function each bedroom, all floors

  • Verify CO detectors on all floors and outside bedrooms if more that one bedroom on a floor

  • walls Ceilings, floors, doors, trim in sound condition and free from damage or deteriorated paint

  • Skeleton Keys disabled or removed

  • Flooring Material in good condition

  • Bathroom and kitchen cabinetry and countertops maintained in sound condition

  • Windows in operable condition and capable of remaining in open position (proper sash control)

  • Windows free of cracks and chips in good condition have properly sealed glazing, and work as intended

  • Water resistant flooring provided in kitchens and bathrooms, in sound condition and free from tears, breaks or other damage

  • Handrails provided on basement, second, third story and attic stairways

  • Fire separation provided between units at common walls, floors ceilings, etc.

  • All interior areas of the dwelling including the cellar, basement, and crawl space remain dry to prevent conditions conducive to decay or deterioration of the structure

  • No sleeping areas permitted in basements unless proper egress windows or equivalent are installed and clear separation is provided from gas fired appliances.

  • Storage content are located at least 3" from a furnace, water heater and electrical panels

  • No combustible, flammable, explosive or other hazardous materials or rubbish may be stored in the dwelling or where they may pose a hazard to the property or the neighbors.

  • Electrical Unit 1
  • Exterior Plugs (GFCI) protected with approved covers

  • Garage, Laundry, bathroom, and kitchen counter plugs are tamper resistant GFCI protected

  • interior 3 prong outlets are properly connected with ground and secured with cover plates

  • Interior 2 prong receptacles are secured with cover plates

  • minimum of 2 receptacles in each habitable room

  • light/ light switches or plugs for lighting provided within 6' of all entry doors to habitable rooms

  • electrical service bonded to exerior ground wires and to electrical meters with jumper wires

  • 3 way switching required at interior second or third story stairways to habitable areas

  • Service Panels are labeled

  • wiring through basements, garages and occupied attic areas are secure (not loose or hanging)

  • Electrical wiring in basement is run through the floor joists or batter boards are provided to protect wiring ran below floor joist framing.

  • Verify uniform service on home service meter to exterior service panel (ex: 100 amp/ 100 amp)

  • Light Fixtures, plugs, switches, covers in place and free from damage

  • Plumbing Unit 1
  • Adequate water pressure provided to fixtures in kitchen and bathrooms

  • sinks, toilets, tubs, and showers free of leaks at the drains, traps and fixtures

  • Tubs, showers, vanities caulked to prevent water infiltration

  • Shut off provided for water meter

  • Drain lines and water lines adequately supported

  • Mechanical
  • Operational Heating in all units

  • Clean furnace filter

  • Exhaust pipes at furnace and water heater & boilers in sound condition and free of damage

  • Furnace and water heater flue pipes are sealed where they penetrate the basement wall or chimney

  • Relief pipe at water heater extends within 6 inches of the floor

  • Drip legs provided on gas lines at furnace, water heater, etc

  • Gas Stove burners operational

  • shut off valves provided to all gas fired fixtures or appliances

  • Exhaust fans provided in all bathrooms or operable window provided ventilation

  • nonworking, defective or obsolete systems or parts of systems fully removed

  • General Unit 1
  • Excess clutter removed

  • All stairways accessible

Untitled Page

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.