Title Page
-
Project:
- Legends of Woodbury
- New Prague Senior Living
- Grand Central Flats
- Thomas Avenue Flats
- Louisiana Lofts
- Rosa Place
- Southview of Eden Prairie
- Affinity of Ramsey
- Harvestview Place
- Sarazin Flats
- Bluffs at Liberty Glen
- Preserve at Shady Oak A & B
- Legends of Minnetonka
- Landings at Lexington
- The Boulevard
-
Client
- Aaron Smith
- Brandon Anderson
- Chris Flintrop
- Dan Erdahl
- David Erdahl
- Doug Morey
- Keenan Hemming
- Lance Nordin
- Nathan Franta
- Barry Braithwaite
- Matt Flintrop
- David Johnson
- Tanya Pardun
- Andy Haney
- Jacob Juhl
- Kory Johnson
-
Project Manager(s)
- Chad Weis
- Kyle Dillon
- Nick Williams
- Shawn Rasmussen
- Tyler Rivard
- Amanda Comstock
- Mark Tangen
- Faseka Tamerat
- Barry Braithwaite
- Riley Sletten
-
Conducted on
-
This inspection report should verify that all siding and accessories are being installed per manufacturer's installation instructions and project plans & specifications. Follow up is required for any deficiencies noted. Forward documentation (I.e. Photos, written report(s), etc.) once deficiencies are corrected to QC Admin.
-
Subcontractor doing the work:
-
Type of siding inspected:
-
Elevation:
-
Submit this report with photos daily for the first (5) days an activity is taking place and (1) time per week thereafter until scope is complete.
-
1. Kick out flashings installed where required:
-
2. Penetrations have all been sealed per the manufacturer's installation instructions, caulking & tape are approved by Tyvek or manufacturer of building wrap:
-
3. Drip cap installed over all window and door locations (sealed to Tyvek):
-
4. Fasteners used are per specifications:
-
5. Proper flashings at inside corners, windows, doors, and at dissimilar materials:
-
6. Installation is allowing for lumber shrinkage at windows, doors, and at dissimilar materials:
-
7. Metal flashing seams/overlaps are sealed per specifications:
-
8. Metal flashings have positive drainage away from building and have allowed for lumber shrinkage:
-
9. Specific deck flashings per project requirements:
-
10. HVAC units (i.e. Magicpaks, etc.) have been flashed per plan and spec:
-
11. Drainage wrap inspection has taken place prior to siding installation starting:
-
12. Cut siding and trim edges are sealed with approved paint or sealant:
-
13. Siding has required clearance from grade, roof, patios, decks, windows, and doors:
-
14. Siding has proper clearance from trim to allow for sealant installation:
-
15. Trim materials have weather cuts:
-
16. Trim blocks are used around penetrations greater than 1-1/2":
-
17. Inside corners have metal flashing over building wrap if specified:
-
18. Respond yes if the crew or foreman HAS NOT changed:
-
If the crew or foreman has changed, stop work and review the project plans and specifications, manufacturers specifications and the pre-installation meeting minutes. Please note action taken:
-
Comments:
-
19. Document work in progress with (2) or more photos for the first 5 days of activity taking place. After the first 5 days, (2) or more photos to be taken per week. <br><br>Photos have been taken and submitted to QA Admin:
-
Additional items to check from pre-install meeting
-
A.
-
Was this completed or did it pass inspection?
-
B.
-
Was this completed or did it pass inspection?
-
C.
-
Was this completed or did it pass inspection?
-
Signature