Information
-
Document No.
-
Audit Title
-
Client / Site
-
Conducted on
-
Prepared by
-
Location
-
Personnel
-
NOTES: (R) Random sampling check. Include dates of service where possible.
CONTRACTOR MANAGEMENT
-
1. Are all restricted areas locked and signage clearly displayed?
-
2. Is there a contractor lockbox onsite?
-
3. Is the contractor box locked and all relevant forms stocked?
-
4. Are contractors using the contractor induction box?
-
5. Are all contractors signing in on every site visit?
-
7. Has the Hazard Awareness Chart been updated in the last 12 months?
-
6. Are all contractors inducted and reviewed every 12 months?
FIRE PROTECTION SYSTEMS
-
1. Is a Service Provider regularly testing and maintaining the following components to the relevant Service Agreement and appropriate State legislation:
-
A - Fire extinguishers (R)
-
B - Fire Hose Reels (R)
-
C - Fire Doors
-
D - Fire Alarm System
-
E - Fire Sprinkler System
-
Is there a sprinkler block plan on site
-
F – Hydrants
-
Is there a block plan on site
-
G - Early Warning Intercommunication System (EWIS)<br>
-
H - Emergency Lighting & Exit Signs (R)
-
2. Has Flow test been done?
-
3. Are Fire Cupboards (hose reel storage etc) free from stored materials and rubbish? (R)<br>
-
4. Are Portable Fire Extinguishers and Fire Hose Reels clearly signed? (R)<br>
EMERGENCY MANAGEMENT
-
1. Is the emergency evacuation plan clearly displayed in all areas?
-
2. Are ALL Fire Doors / Breakout panels operational?
-
3. Are assembly areas allocated and understood?
-
4. Has a practice drill occurred in the last six months?
-
When was the last Warden training conducted? (6 monthly)
-
5. Are the means of escape paths and emergency exits clear?
ELECTRICAL (COMMON AREA EQUIPMENT ONLY)
-
1. Has electrical equipment and Residual Current Devices been tested / tagged in last 12 months?
-
2. Are power points being used appropriately (i.e no multiboards, double adaptors, etc)
-
3. Has Distribution Board had thermal test done in last 12 months
HAZARDOUS SUBSTANCES
-
1. Are there any hazardous materials or dangerous goods present on site?
-
2. Is Hazmat register current?
-
3. Are the materials or goods stored correctly?
-
4. Are Material Safety Data Sheets (MSDS) available for all dangerous goods?<br>
-
Is a copy of the MSDS held at the Fire Panel for QFRS?<br>
-
5. Is there asbestos on site.
-
Is the register up to date.
-
Sighted Register
-
Photo evidence (as required)
-
6. Is a spill kit on site and is it complete?
FIRST AID
-
1. Is a first aid kit supplied?
-
2. Has the first aid kit been audited in the last year?
-
3. Are all injuries reported and recorded in a book or form?
-
4. When first aid equipment is used is it recorded?
-
5. Is a sharps kit available?
INTERIOR ENVIRONMENT
-
1. Is there a shared common area?
-
2. Are stairways and aisles kept clear and useable?
-
3. Are lighting levels satisfactory?
-
4. Is the general presentation and cleanliness satisfactory e.g. Ceilings, high glass, furniture?
-
5. Are toilets clean and adequately stocked with supplies?
-
6. Are the kitchen/tea rooms clean?
-
7. Is air conditioning within operational limits?
-
8. Is the directory board up to date?
-
9. Are vacant areas clean and presentable?
-
10. Are lifts clean, well lit and are the emergency phones operational? (R)
-
11. Are public facilities and large common areas (i.e food courts, etc) well presented?
-
12. Are floors and surfaces in good condition?
-
13. Has the area had a slip test in the last 12 months?
EXTERIOR ENVIRONMENT
-
1. Are exterior walls and surfaces clean and in good repair?
-
2. Are paths and external stairs in good condition?
-
3. Are parking areas tidy and bollards/speed humps undamaged?<br>
-
4. Is the line marking & signage adequate in the car park area?
-
5. Are driveways clear and free of hazards?
-
6. Are roller doors / boom gates / dock levellers operational / undamaged?
-
7. Is exterior / security lighting working?
-
8. Are drains / grates clear of rubbish?
-
9. Are waste bins regularly emptied and area clean / tidy?
-
10. Are fences / gates undamaged?
-
11. Are landscaped areas well presented & free from rubbish?<br>
PLANT & EQUIPMENT
-
1. Are all access ladders and stairways in good condition?
-
2. Are the lifts and escalators serviced frequently?
-
3. Does the car park ventilation system appear to be working correctly?
-
4. Are ALL plant rooms neat and tidy, free from debris and trip hazards?
ROOF
-
1.Is roof access restricted and is permit system in place?
-
2. Is the roof area free from debris and trip hazards?
-
3. Are gutters clear and in good condition? (R)
-
4. Are roof walkways and perimeter barriers in good condition?
-
5. Are there Anchor points on the roof?
-
Are these anchor points rated?
-
Have these anchor points been tested in the last 12 months?
ENVIRONMENTAL
-
1. Have Thermostatic Mixing Valves been serviced (Annual)
-
2. Has the back flow device been tested?
-
3. Are grease traps serviced as per regulations?
-
4. Are all pumps operational and regularly serviced?
WORKPLACE SAFETY
-
1. Are there any confined spaces areas on site?
SECURITY SYSTEM & ACCESS CONTROL
-
1. Is there a secure access control system to the premises?
-
2. Is there a service & maintenance agreement in place?
-
3. Is there a record of all cards and keys on site?
-
4. Is there a CCTV system in the building?
-
5. Is there an ongoing service & maintenance agreement in place?
DISABILITY ACCESS & COMPLIANCE
-
1. Is the site access compliant?
-
2. Are there disabled access ramps to the entrance
-
3. Do the lifts have braille & voice?
-
4. Are there tactile indicators on paths and before/after stairs?
-
5. Are there disabled access amenities on site?
COOLING TOWERS
-
1. Does the site have cooling Towers
-
2. Is there a contract in place for the chemical treatment
-
3. Are records readily available for auditing purposes