Electrical Installation Condition Report

  • RCDs provided for additional protection which includes RCBOs

  • RCDs provided for protection against fire which includes RCBOs

  • Manual operation of circuit-breakers and RCDs to prove disconnection

  • Presence of RCD retest notice at or near equipment where required

  • Presence of diagrams, charts or schedules at or near equipment where required

  • Presence of non-standard (mixed) cable color warning notice at or near equipment where required

  • Presence of alternative supply arrangement warning notices (s) at or near equipment where required

  • Presence of replacement next inspection recommendation label

  • Presence of another required labeling

  • Examination of protective device and base; correct type and rating (no signs of unacceptable thermal damage, arcing or overheating)

  • Protection against mechanical damage where cables enter equipment

  • Protection against electromagnetic effects where cables enter metallic enclosures

  • Distributional circuits

  • Identification of conductors

  • Cables correctly supported throughout their length

  • Condition of insulation of live parts

  • Non-sheathed cables protected by enclosure in conduct, duct or trunking

  • Suitability of containment systems for continued use (including flexible conduct)

  • Cables correctly terminated in enclosures

  • Distribution/final circuits

  • Non-sheathed cables protected by enclosure in conduit, duct or trunking

  • Suitability of containment systems for continued use (including flexible conduit)

  • Cables correctly terminated in enclosures

  • Examination of cables for signs of unacceptable thermal and mechanical damage/deterioration

  • Adequacy of cables for current-carrying capacity with regard to the type and nature of the installation

  • Adequacy of protective devices; type and rated current for fault protection

  • Presence and adequacy of circuit protective conductors

  • Co-ordination between conductors and overload protective devices

  • Cable installation methods/practices appropriate to the type and nature of installation and external influences

  • Cables where exposed to direct sunlight, of a suitable type

  • Concealed cables installed in prescribed zones

  • Concealed cables incorporating earthed armor or sheath, or run within the earthed writing system, or otherwise protected against mechanical damage caused by nails, screws and the like where not in prescribed zones

  • Provision of additional protection for cables concealed in walls or partitions

  • Provision of fire barriers, sealing arrangements and protection against thermal effects

  • Band II cables segregated/separated from non-electrical services

  • General condition of wiring systems

  • Temperature rating of cable insulation

  • Condition of accessories including socket-outlets, switches, and joint boxes

  • Suitability of accessories for external influences

Completion

  • Full Name and Signature of Authorized Person

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.