Title Page

  • Construction Review-Seabourn Encore

  • Department/Sectors

  • Conducted on

  • Prepared by

  • Attended by

Food Preparation Areas

Equipment

  • Do the blast chillers suffice in numbers and size based on the size of the area, menu variety and volume of food prepared?

  • Do all of the following sections have an utility sink?

  • Gardemenger

  • Meat Prep

  • Fish Prep

  • Veg Prep

  • Are there sufficient storage cabinets, shelves, or racks for food products?

  • Are there sufficient storage cabinets, shelves, or racks for utensils and food equipment?

  • Are there sufficient portable and fixed tables, carts and trolleys?

  • Is there sufficient storage space for all of the below?

  • Ladles

  • Paddles

  • Whisks

  • Spatulas

  • Is there a knife locker installed?

  • Are there storage areas for waiter or bar waiter trays?

  • Are there dish lowerators and plate trolleys?

  • Is there glass rack storage?

  • Are there preparation counters and is size and number adequate?

  • Are there sufficient drinking fountains that are hands free with no bottle filling spout?

  • Drainage: Does all fixed installed equipment discharge waste water into a deck drain?

  • Ice cream dispensing: are there dipper wells installed?

  • Counters top openings: Are openings on counter tops protected by an elevation such as rim or frame?

  • Material: Are all materials used on food contact and non food contact surfaces are smooth, durable and non corroding?

  • Surfaces: Are all surfaces smooth, durable, non-corroding, easily cleanable and accessible?

  • Corners I: Are corners COVED and seamless?

  • Cornets II: Do corners form external angles with a sufficient radius to permit proper drainage and without sharp edges?

  • Sealants: Are sealants for food contact surfaces meeting NSF 51 or equivalent standard, are hard sealants and not excessively applied?

  • Working counters: No sharp edges?

  • Closure Means: Ice there appropriate protective means for all of the below?

  • Ice bins

  • Food displays

  • Ice holding units

Equipment-Placement & Mounting

  • Is all mounted equipment A - sealed to the countertop or bulk head, table top counter top, adjacent equipment or B- installed leaving sufficient, unobstructed cleaning space all around the equipment? <br>

  • If scenario B is present, if the cleaning distance is less than 60cm, is there unobstructed cleaning space of at least 15cm?

  • If scenario B is present, if the cleaning distance is between 60cm and 120cm, is there unobstructed cleaning space of at least 20cm?

  • If scenario B is present, if the cleaning distance is greater than 180cm, is there unobstructed cleaning space of at least 46cm?

  • Is equipment that is not sealed to the deck, is it elevated at least 15cm from the point of cleaning access?

  • Is all deck mounted equipment continuously welded, smoothly onto stainless stell plates, without gaps?

  • If coaming is applied to seal off equipment, is the equipment no more than 10cm overhanging from the base?

  • If coaming is applied, is cement or an equivalently hard sealant used?

  • If equipment is mounted to the counter, do the below scenarios meet compliance?

  • Are all food contact surfaces or connections to food contact surfaces/ splash zones attached with seamless, coved corners?

  • Are there no slotted casters used on food contact or splash zones?

  • Are fasteners non corroding?

  • Are all hinges, covered and made of noncorroding material?

  • Are latches and handles made of non corroding material that is easily cleanable?

  • Are all wires and cables elevated off the counters?

  • Are all wires and cables elevated off the deck?

Gaskets

  • Are the gaskets smooth, non porous, non absorbent and removable?

Buffets, Waiter Stations, Bars

Sneeze Guards

  • If there is solid vertical shield, is it raised 140cm from the deck to the top of the shield?

  • Are sneeze guards made of smooth, easily cleanable plastic or glass?

  • Are there no gaps greater than 2,5cm wherever there is food placed underneath?

  • Is the maximal vertical distance between counter top and the bottom of the sneeze guard pane no more than 35,6cm?

  • Are there side shields installed?

  • Buffet lines: Are the hard decks at least 100cm in size around the buffet measured from the outer edge of the counter?

  • Waiter stations: Are the waiter stations on hard decks extending 60cm from the working side?

  • Bars and Buffets: Are there compliant covings installed on the worker side?

  • Buffet and Waiter Stations: Are there compliant covings on the consumer side of buffets<br>, areas shared with workers or waiter stations?

  • Are there hand wash stations, one per 100 seats, installed at each entrance of self service buffets? (At least one per entrance adding up)

  • Are there means to provide all necessary hand wash sink supplies including a sign advise to wash hands prior to entrance?

  • Are the hand sinks easily cleanable and non absorbent?

  • Bars: Are bars accessible for staff in such way that stooping or crawling is not necessary?

Hood Systems for Cooking Equipment and Hot Holding Equipment

  • Are there hoods above all cooking equipment?

  • Are there hoods above all hot holding equipment?

  • Does the installation prevent accumulations of condensation befitting the unit?

  • Are the filters removable for cleaning or can the system be cleaned otherwise?

Ware washing areas

  • Is there a 3 compartment sink or a dish washer machine or both?

  • 3 compartment Sink

  • Dish washer

  • Adjacent dump sink and overhead sprayer

  • Is the strainer in the sink removable?

  • Is there a 3 compartments sink plus either a 4th sink or a designated pre wash station with insert pan and over head spray installed?

  • Are the sinks of the 3 compartment sinks large enough?

  • Are clean dirty areas separated?

  • Are there gutters and drains across the areas between the sinks?

  • Are there splash shield of at least 25mm installed between each sink?

  • Is there an overflow drain at the wash sink 100mm below the flood rim?

  • Are the floors beneath the shelves accessible for cleaning?

  • Are there splash panels installed where there are clean items being stored within 2 meters of a spray hose?

  • Is there a garbage grinder in dish wash areas?

  • Is there a removable splash panel protecting the grinder ( food waste system)?

  • Is there a food waste trough extending full length of soiled landing tables?

  • Is the rear area of the soiled landing area sealed?

  • Are there drains, across the landing table of the clean side leading straight into a scupper?

  • Is there sufficient space for cleaning around the Equipment?

  • Are there no open wires and cables?

Walk in Fridges and Freezers

  • Are the drain lines from the evaporator sloped and extended through the bulkhead or deck?

  • Are the condensate lines lead through an air-break into a drain outside the unit?

  • If a drain line is installed horizontally, is it at least 10cm above the deck and sloped to drain?

Food Equipment Drain Lines

  • Length: Are they less than 100cm and free of sharp angles if intended to be cleaned by brush?

  • Cleaning: if they are longer than 100cm, are they readily removable for cleaning?

Beverage areas

  • Are beverage dispensing devices equipped with readily removable drip trays or fixed installed drains into a deck scupper.

  • Condiment dispensers: Are there readily removable trip trays installed?

  • Storage areas: Are they designed to accommodate all food equipment and utensils?

  • Counters top openings: Are openings on counter tops protected by an elevation such as rim or frame?

  • Working counters: No sharp edges?

Deck, Bulkhead, Deckhead.

  • Are the structural parts, such as deckheads and bulkheads free of exposed fasteners?

  • Are all seams between adjoining bulkheads and deck heads closed?

  • Are gaps between 0.8mm and 3mm closed with an appropriate sealant?

  • Are gaps greater than 3mm cleanse using profile strips?

  • Are all penetrations covers using non corroding material?

  • Are all bulkheads reinforced preventing buckling and becoming detached?

  • Are door penetrations leaving no exposed voids?

  • Are covings installed at deck bulkhead junctures where applicable?

  • Are the materials used for covings hard and securely fastened?

  • Are the decks of hard, durable, non skid material that is easily cleanable?

  • Are decks inside technical spaces made of stainless steel or tiles?

  • Are deck tiles sealed with durable, watertight grouting?

  • Are all deck penetrations sealed?

Deck Drains, Deck Sinks & Scuppers

  • Are all sinks and scuppers made of stainless steel?

  • Are scupper grates made of Stainless Steel and have no sharp edges?

  • Are the scupper grates fitting tightly yet can be easily removed for cleaning?

  • Are there deck drains in front of soup kettles, tilting pans, boilers or braising pans?

  • Are the sizes of the deck drains appropriate to eliminate spillage and overflow to deck surfaces?

  • Are the coamings of deck drains coved to the deck side?

Food Hygiene Facilities Requirements

Hand Wash Stations

  • Is there hot and cold Potable Water supplied?

  • Is the hot water producing a temperature of at least 38C (100F)?

  • Are hand sinks in food areas constructed of stainless steel?

  • Are hand wash sinks in bars and food service areas made of similar, smooth material?

  • Are hand wash sinks supplied with all of the below?

  • Soap

  • Paper towels

  • Receptacle

  • Sign "wash hands often"

  • Are the above items removable for cleaning or sealed off?

  • Are soap dispensers and paper towel dispensers installed not above other clean equipment or surfaces?

  • On multiple sink stations, are the soap dispenser installed within 38 cm or the sink?

  • On multiple sink stations, are the paper towel dispensers installed within 76cm of the sink?

  • Are the paper towel dispensers installed at least 45 cm above the deck measured from the lower edge of the dispenser?

  • Are the hand wash sinks installed at least 60cm above the deck?

  • Are hand wash sinks installed, in Food areas, at least one every 8 meters of unobstructed access?

  • In provision areas, is there hand wash sink where bulk-raw foods are being handled?

  • Is there one hand wash sink in the crew mess per 100 seats?

  • Are there hand washing sinks installed at the dirty dishes drop off area, one per 10 service staff?

  • Are the hand sinks easy to operate?

Bucket filling stations

  • Is there at least one bucket filling station per area in the galley or the individual food prep area?

  • Is there hot and cold water and a drain?

Toilets

  • For all of the below locations, Is there one toilet per 25 employees, separate facilities for males<br><br>and females if more than 25 employees work in a FOOD PREPARATION<br><br>AREA, excluding wait staff, during maximal shift capacity, provided?

  • Crew Galley

  • Main Galley

  • For all other outlets, are there toilets no more than two stair cases away within the same fire zone or, if on the same deck, no more than one fire zone?

  • Sushi

  • Thomas Keller

  • Colonnade

  • Provisions

  • Are all doors self closing?

Lighting

  • Are all of the below areas illuminated for cleaning purpose with at least 220 lux at work surface level or 76cm above the deck?

  • Food Reparation Areas

  • Food Service Areas

  • Ware Washing Areas

  • Equipment Storage

  • Garbage Areas

  • Food Lifts

  • Toilet Rooms

  • Empty Provision Rooms

  • Waiter Stations

  • Are all zones behind Equipment illuminated with 110 lux?

  • Are hand sinks, while the area is use, illuminated with 110lux?

  • Are full store rooms illuminated with 110lux 76cm above the deck?

  • Are all heating lights shatter proof?

  • Are all lights covered?

  • Are all lights intact?

Lockers

  • Are all lockers meeting the construction guidelines for facilities used for storage of food equipment?

  • Is there no galvanized shelving used?

  • Are all cleaning lockers labeled " Cleaning Materials Only"?

  • Is there a vented, cover locker for storage of buckets, chemicals or wet items?

  • Is there a locker with a mop sink and adequate deck drain unless it's on the dirty side of the ware washing area?

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.