Title Page
-
Design Critique Report - Speciality Shops
-
Tenancy name:
-
Tenancy Number:
-
Centre Name:
-
Began On:
-
Appointment of Retail Designer
-
Design Drawings
-
Scope of Refurbishment Works
DCR Items
-
Shopfront
- Remove existing shopfront and replace with new concept to lessor current guidelines.
- Shopfront to be on the lease line.
- Reconfigure existing shopfront to a new design concept.
- Reclad existing shopfront with new finishes.
- Make good all wear and tear to the shopfront and restore to look as good as new.
- Refer Appendix 1
-
Comments
-
Shopfront Glazing
- Remove all existing glazing. New glazing specification to allow for full height glazing, butt joined, concealed mullions and no full height blade fins.
- Professional clean of existing glazing, mullions and skirting (where applicable).
- Retain existing glazing and make good all wear and tear restore to look as good as new. This includes polishing to remove any surface scratches and professional clean of glazing. Glazing channels to be clad over & concealed.
- Retain existing, any exposed glazing channels to be reclad in lessor approved finish and in keeping with overall shopfront treatment.
- Refer Appendix 1
-
Comments
-
Signage
- Remove existing signage and replace with new concept to lessor current guidelines.
- Redesign existing signage bring in line with current design trend & lessor guidelines.
- Make good all wear and tear, restore to look as good as new.
- Refer appendix 1
-
Comments
-
Entry Doors
- Remove existing entry closure and replace with new to suit new shopfront to meet current lessor guidelines.
- Full service of entry doors, including replacement or repair of any damaged components.
- Make good all wear and tear to the existing entry doors to restore to look as good as new. Ensure doors can fully retract.
- Refer Appendix 1
-
Comments
-
Floor Coverings
- Remove existing floor covering and replace with new. Solid floor finish to be installed along the lease line.
- Replace any damaged tiles, regrout where required and professional clean and polish.
- Sand and polish existing timber floors, restore to look as good as new.
- Replace any damaged vinyl and a professional clean and polish.
- Replace any damaged sections of carpet and allow for a professional clean. Solid floor finish to be installed along the lease line.
- Replace any damaged sections of floating floors. Solid floor finish to be installed along the lease line.
- Existing polished concrete floor, to be reskimmed & sealed.
- Refer appendix 2
-
Comments
-
Ceiling
- Remove existing ceiling and replace with new articulated flush plasterboard ceiling.
- High level clean of existing flush plasterboard ceiling required, replace any damaged plasterboard.
- High level clean of existing grid and tile ceiling required, replace any damaged components.
- Retain existing ceiling throughout.
- Incorporate alternate finish as ceiling feature
- Refinish existing ceiling feature to look as good as new.
- Patch and paint the existing ceiling throughout.
- Install flush plasterboard ceiling to first 3m of the tenancy and replace remainder of tiles with new.
- Refer appendix 3
-
Comments
-
Lighting (lighting throughout tenancy to be compliant with BCA
- Replace with new recessed approved light fixtures to suit new plasterboard ceiling. Confirm lux levels to meet current lessor guidelines.
- Replace existing fluorescent light fittings with new approved recessed light fittings. Confirm lux levels.
- Provide additional lighting to improve store illumination. Confirm lux levels.
- Reconfigure lighting layout throughout incorporating feature lighting & addressing fixture illumination.
- Retain existing light fittings and relamp to ensure even colour rendition. Confirm lux levels.
- Refer appendix 3
-
Comments
-
Walls
- Repaint in new colour scheme.
- Patch & paint and make good all wear & tear
- Apply new wall finish, feature walls & treatment to improve visual impact of interior scheme.
- Retain existing wall finishes.
- Refer to appendix 4
-
Comments
-
Wall Merchandising Units
- Remove existing merchandising units and replace with new. All lighting (where applicable) to be built into joinery units. (Assisting BCA requirement).
- Reclad with new approved finishes.
- Refurbish and make good all wear and tear, restore to look as good as new.
- All lighting to be built into joinery units.
- Reconfigure existing wall merchandising units.
- Refer appendix 4
-
Comments
-
Floor Merchandising Units
- Remove existing floor units and replace with new. All lighting (where applicable) to be built into joinery units, conceal all exposed power supply.
- Reclad with new approved finishes.
- Refurbish and make good all wear and tear to look as good as new.
- All lighting to be built into joinery units.
- Reconfigure layout of existing floor merchandising units, providing clear pathways.
- Retain existing floor merchandising units.
- Reassess unit heights and lay-out, addressing sightline issues.
- Refer appendix 2
-
Comments
-
Window Merchandising Unit
- Remove existing window units and replace with new. All lighting (where applicable) to be built into display.
- Refurbish and make good all wear and tear to look as good as new.
- Reconfigure existing window display, creating strong visual impact.
- Retain existing window display.
- Reassess unit heights and lay-out, addressing sightline issues.
- Recess all suspension systems into ceiling.
- Implement professional display systems.
- Refer appendix 1
-
Comments
-
Visual Merchandising
- Separate drawing dedicated to proposed Visual Merchandising plan to be submitted for approval
- Engage services of a professional Visual Merchandiser to implement Visual Merchandising
- Refer appendix 1
-
Comments
-
Sales Counter
- Remove existing sales counter and replace with new to meet current lessor guidelines.
- Retain existing sales counter and reclad with approved finishes.
- Make good all wear and tear restore to look as good as new.
- Refurbish existing sales counter to incorporate fully recessed equipment.
- Relocate to suit new design concept.
- Retain existing sales counter.
- Refer appendix 5
-
Comments
-
Internal Signage
- Remove existing internal signage and replace with new concept. To be in keeping with shopfront signage.
- Make good all wear and tear to the internal signage to look as good as new.
- Incorporate internal signage for stronger brand presentation.
- Refurbish in keeping with new shopfront sign.
-
Comments
-
Plasma Screens
- Remove unapproved plasma screen and submit drawings as per design guidelines for the reinstallation of all digital technology
- All future proposed digital technology must be documented as part of the design documentation and submitted for approval. Installation specification must comply with Retail Design Guidelines
-
Comments
-
Ticketing / Price Point
- To be professionally printed and displayed.
- Standardise utilising a professional system.
- Standardise utilising a professional system to address sight line issues.
-
Comments
-
A/C Registers
- Install all new diffusers to suit new concept.
- Detailed clean or paint to match ceiling colour (if applicable).
- Recommend installation of 4 way registers.
- Incorporate new diffusers. E.g. Linear slot or circular to suit new ceiling.
- Confirm with landlord approved contractor that sufficient air supply is provided.
-
Comments
-
Fitting Rooms
- Remove existing fitting rooms and replace with new.
- Address fitting room location/layout within the existing tenancy.
- Reclad with new approved finishes.
- Refurbish and make good all wear and tear to look as good as new.
- Address lighting levels in fitting rooms to ensure sufficient illumination.
- Not applicable.
- Refer Appendix 6
-
Comments
-
Store Rooms
- Install automatic door closer to store room door.
- Ensure all store room walls are full height.
- Ensure all stock within the store room is maintained with a 500mm clearance from sprinkler heads.
- Replace existing store room door with new approved door.
- Not applicable.
- Refer appendix 6
-
Comments
-
Other
- Relocate sound system in keeping with landlord's design guidelines.
- Security system to be built into shopfront entry.
- Ensure all stock within the store room is maintained with a 500mm clearance from sprinkler heads.
- Engage professional visual merchandiser to improve on window and general store presentation
- Mobile merchandising to remain behind the lease line, not to encroach on required pathway clearances.
- No trading beyond the lease line.
-
Comments
-
Media Additions
Inspector Details
-
Report completed by:
-
HO review by:
-
Agreed by leasing: