1. Spray booths, Parts booths and Mix room.
-
Do all doors securely close on all spray booths and the mix room?
-
Are all lights operating properly in booths and mix room?
-
When was the last floor filter change for the spray booths?
-
Are all the floor grates in the spray booths sitting properly? (No raised trip hazards?)
-
Is the mix room clear of unauthorised electrical equipment? (e.g. radios, phone chargers)
-
Does the mix room bench extraction operate efficiently? Can you feel the air being pulled into the vents? Is the room clear of paint or thinners smell?
-
Are all lids kept on containers in the mix room? (e.g. thinners, prepsol, spray pots)
-
Are all paint and solvent based products stored inside the mix room or on bunded pallets? (Check behind the booths)
-
Tap "+" to record running hours for each additional booth
Running Hours for Booth
-
Record the running hours for booth
-
Nothing more than 99999
-
Are all employees wearing the correct PPE? Air fed hood, full body covering, safety footwear for spray painting.
2. Production Areas - General
-
Are all vehicles parked appropriately in designated work bays?
-
Do all vehicle hoists and lifts have the required pads, blocks and securing devices?
-
Have all lifting devices been serviced or commissioned in the past 12 months?
-
Are work bays clean and tidy and free of trip hazards? Power chords and air hoses not left on floor as trip hazards.
-
Is the internal "drive way" clear of obstructions and clearly marked (painted)? Can vehicles safely travel through the site?
-
Are employees working in safe locations away from the risk of collision from vehicles? Are they in their work bays and using vehicle lifts where appropriate?
-
Is the relevant PPE available for employees as required? Protective eyewear, respirators, air fed masks, hearing protection, coveralls.
-
Are spill kits readily available in the workshop and in good condition?
-
Are all trolleys and mobile benches tidy and stored in appropriate locations out of walkways and driveways?
-
Are all welding units in good working order?
-
Have all welding units been serviced according to their schedule?
-
Are all gas bottles secured via a chain to wall storage areas, trolleys or welding devices?
-
Are all fixed bench grinders in good working order with safety screens attached?
3. External drive way and Car Parks
-
Are parking areas for staff and customers clearly sign posted?
-
Is access to the site via vehicle clearly restricted and sign posted for customers and employees alike? e.g. Boom gates, signage or barriers?
-
Are designated smoking areas signposted, have ashtrays clear of rubbish and more than 10 metres away from entry and exit doors?
-
Are waste bins clearly identified - general, recycling (cardboard)?
-
Is prescribed waste correctly stored and labelled? Bunded and separate from general waste?
-
When was the last prescribed waste (oil, paint waste, etc) collection completed?
-
Are all bins (general and recycling) clear of liquid waste evidence (paint, oils, sludge)?
-
Can employees easily access and open the bins to dispose of waste?
-
Are bins suitable in size for the site? (not overflowing, no additional rubbish piles)
-
Does the wash bay contain all waste water generated from washing vehicles
-
What products are used to wash vehicles?
-
Is the sump or drainage pit clear of solids and sludge? When was it last cleared?
-
Are waste oils, solvents and liquids stored in labelled containers on bunded pallets?
4. Fire Safety and Emergency situations
-
Are all fire exits clearly signposted and free of obstruction to allow safe exit in case of Emergency?
-
Are evacuation plans clearly displayed around the site?
-
Is the site Emergency Plan easily accessible?
-
Is the emergency evacuation point clearly signed and free from obstruction? Do all employees know where it is?
-
Have at least 2 Fire wardens and 2 First aiders been appointed and their names displayed on the Safety Board?
-
Have all extinguishers and hose reels been inspected in the past 6 months? Check the label is stamped correctly.
-
Is there clear access to all extinguishers and hose reels?
-
Are first aid kits available, well stocked and their location clearly labelled?
-
Have all power cables, extension leads and fixed electrical cables been tagged and tested within their schedule?
-
Are all switchboards and electrical cabinets in good condition with no obvious damage and no exposed elements?
-
Do you have a High Voltage board or room on site?
-
Is the HV board or room clearly identified and secured to prevent unauthorised access?
Safety Information
-
Has your Safety Board been updated with the latest information? Check the guide and photos provided on your e mail.
-
Do you have designated first aiders and fire wardens and are they displayed on the Safety Board?
-
Has the EAP provider toolbox talk been delivered to the site and the new Eudoxia posters been displayed around the site and on the Safety Board?
-
Have the Hazard reporting QR code posters been displayed around the site for employees to report hazards?
-
Do all employees have access to safe cutting and knife options alongside razorblades?