Information

  • Building Address
  • Building Photo

  • Date Audit Conducted On

  • Name of Auditor

Last Splice

  • Are you checking the Last Splice today?

  • Where is the last splice located?

  • Manhole or Vault?

  • Enclosure Type

  • Mounting Option

  • Enclosure/Mounting Photo

  • Is Splice Case Grounded?

  • Splice Case Grounding Photo

  • Cable Loop Placed Correctly?

  • Cable Loop Photo

  • Spiral Wrap/Tape In Place?

  • Spiral Wrap Photo

  • Cable Tag Placed and Correct Info Visible?

  • Cable Tag Photo

  • Place Any Further Comments on Last Splice Here

  • Enclosure Type

  • Enclosure is Securely Mounted?

  • Enclosure/Mounting Photo

  • Cable Placed and Attached Correctly, Including a Service Loop?

  • Cable Placement Photo

  • Cable Tag Placed and Correct Info Visible?

  • Cable Tag Photo

  • Is Splice Case Grounded to Messenger With a Straight Run - Not a Loop?

  • Splice Case Grounding Photo

  • Is the Correct Height Clearance Observed?

  • Photo of Height Clearance

  • Is there a Drip Loop at the Building?

  • Is a Telus Approved Weatherhead Installed on the Mast?

  • Photo of Building Attachment including Drip Loop.

  • Place Any Further Comments on Last Splice Here

  • Is FDH cabinet Levelled and Secure?

  • Does the Cabinet Location Provide Unobstructed Access?

  • Photo of Cabinet Placement

  • Is There an Orange Label on the Outside?

  • Photo of Orange Label

  • Splitter and Feeder Leg Labels?

  • Photo of Splitter and Feeder Leg Labels

  • Distribution and Feeder Labels?

  • Photo of Distribution and Feeder Labels

  • Blue Jumper Labels on Door?

  • Photo of Blue Jumper Labels

  • Output Pigtails Labelled?

  • Photo of Output Pigtail

  • Are Fibers Terminated?

  • Photo of Fiber Terminations

  • Is Fiber Dressed and Routed Using Available Runways?

  • Photo of Fiber Dressing/Routing

  • Is the Bottom Gasket Installed?

  • Photo of Bottom Gasket

  • Is there Grounding to a Ground Rod?

  • Photo of Grounding

  • Place Any Further Comments on Last Splice Here

  • Is the Pedestal Labelled on the Outside?

  • Pedestal Label Photo

  • Is the MPT Mounted?

  • Are 4 Slack Brackets Installed?

  • 1.5m+ of MPT Tail Wraps Placed?

  • MPT Pedestal Installation Photo

  • Place Any Further Comments on Last Splice Here

Entrance Cable

  • Are You Checking an Entrance Cable Installation Today? (Should also be Selected if You are Auditing a Termination Panel

  • How does the Cable Enter the Building?

  • Outer Wall or Roof Penetration; Weather Sealing Performed?

  • Outer Wall or Roof Penetration; Weather Sealing Photo

  • If Needed - Further Comments on Outer Wall or Roof Penetration; Weather Sealing

  • Is the Entrance Point/Conduit Sealed Inside?

  • What is the Sealing Method?

  • Photo of Entrance Point/Conduit Sealant

  • If Needed - Further Comment on Entrance Point/Conduit Sealant

  • Is there more than 3m of Entrance Cable? (Include the Service Loop)

  • Photo of Less than 3m of Entrance Cable

  • Has FT4 Fire Rating has been Achieved?

  • How is Fire Rating Achieved?

  • Photo to Show how Fire Rating is Achieved?

  • If Needed for Further Comments on Entrance Cable Fire Rating.

  • Is the Entrance Cable Secured to the Wall?

  • Which Secure Attachment Method is Used?

  • Photo of Secure Attachment to the Wall

  • If Needed for Further Comment about Secure Attachment to the Wall

  • Are Cable Tags in Correct Place with Correct Information?

  • Photo of Cable Tags in Correct Place...

  • ...with Correct Information

  • If Needed for any Further Comments on Cable Tag Placement and Information

  • Has Spiral Wrap or Tape been used?

  • Photo of Spiral Wrap or Tape

  • If Needed for Further Comments on Spiral Wrap or Tape

Termination Panels

  • Are you checking a Termination Panel Today?

  • Which Electrical Room is the Termination Panel in? eg MER, SER 1, SER 2 etc

  • Where is the Electrical Room Located? eg North side of parkade. 2nd floor west end of hallway.

  • What Type of Panel are you Auditing?

  • Is there Unobstructed Access to the Panel and can the Door Open Properly?

  • Photo of Access to Panel

  • If Needed - Further Comments on Access to Panel.

  • Is the Outside of the Panel Labelled Correctly?

  • Photo of Outside Panel Labelling

  • If Needed - Further Comments on Outside Panel Labelling.

  • Is the Incoming Cable Properly Secured?

  • Does the Incoming Cable have a Service Loop?

  • Photo of Incoming Cable Dressing

  • If Needed - Further Comments on Incoming Cable Dressing

  • Do the Outgoing BIF's have Service Loops?

  • Photo of Outgoing BIF Service Loops

  • If Needed - Further Comments on Outgoing BIF Service Loops

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.