Information
-
Document No.
-
Audit Title
-
Client / Site
-
Conducted on
-
Prepared by
-
Location
-
Personnel
INTRODUCTION
-
Name of Airport?
-
What is the Airport ARFF Index?
-
What is the Airport Classification?
-
Does the proposed ARFF station provide adequate space for ARFF personnel, vehicle, equipment, and their related functions as prescribed by FAR 139.317 for certification?
-
Does the department provide EMS service?
-
Is a bay needed for over-head vehicle servicing?
ARFF APPARATUS BAYS (AC 150/5210-15)
-
Meets vehicle configuration (L/H/W) according AC 150/5210-15 Appendix A
-
Free personnel access from all interior / exterior access points.
-
Side by side parking versus tandem parking
-
Drive through bays
-
Observer's Comments:
ARFF APPARATUS BAYS STANDARD CLEARANCES (AC 150/5210-15)
-
6 feet between vehicles walls and storage areas.
-
8 feet between vehicles parked side by side.
-
5 feet between vehicle parked end to end.
-
5 feet between the vehicle and apparatus bay doors
-
7 feet between the top of vehicle platform and ceiling.
-
10 square feet of Personal Protection Equipment Storage.
-
Is 10% of space allocated for additional apparatus bay storage?
-
Observer's Comments:
ARFF APPARATUS BAYS ELECTRICAL DETAILS (AC 150/5210-15)
-
Are lighting levels provided per AC 150/5210-15, Chapter 3?
-
Are electrical outlets provided 18" - 24" above the floor and spaced at 8 feet intervals?
-
Are retractable electrical reels provided that service vehicle electrical systems?
-
Conduit should be provided to allow for future expansion
-
Observer's Comments:
ARFF APPARATUS BAYS INTERIOR ENVIRONMENT (AC 150/5210-15)
-
Is a vehicle exhaust extraction system provided and vented to the outside?
-
Are carbon monoxide detectors installed to sense CO in living quarters?
-
Are walls designed for easy cleaning and low maintenance?
-
Observer's Comments:
ARFF APPARATUS BAYS VEHICLE SUPPORT EQUIPMENT (AC 150/5210-15)
-
Is an over-head hoist provided?
-
Is the over-head hoist a minimum 1 ton rated device?
-
Has a vehicle water re-supply connection been provided (AC 150/5220-4)
-
Is a utility room provided with a deep slope sink, hot / cold water outlets, and mop wriner?
-
Is the utility room provided at least 64 - 100 square feet in size?
-
Is a compressed air supply capable of supplying a minimum of 120 psi available to maintain vehicle air supply system?
-
Is a foam agent recharging capability provided? Is it a overhead system or a transfer pumping system?
-
Observer's Comments:
ARFF APPARATUS BAY DOORS (AC 150/5210-15)
-
Are apparatus bay doors a minimum 16 X16 feet?
-
Is the maximum time to raise apparatus bay doors 16 seconds?
-
Are doors remotely operated from the alarm / watch room?
-
Is each door provided with a separate electrical operating control switch located adjacent to the door?
-
Are doors provided with a manual pull chain in the event of electrical system or switch failure?
-
Is each apparatus / bay door provided with a manual over-ride?
-
Are doors equipped with adjustable timers designed to close to prevent energy loss?
-
Are automatic door retractors provided on each door?
-
Are electrical "eye beams" installed to reverse door closing? Are they correctly mounted and do they function properly to preclude equipment or personnel injury?
-
Are apparatus bay doors insulated and provided with weather stripping?
-
Are doors equipped with windows? If windows are installed, are they tempered safety glass, and shatter proof?
-
Observer's Comments:
ARFF APPARATUS BAYS VEHICLE ROOM FLOOR (AC 150/5210-15)
-
Are floor surfaces resilient to various liquids? Are they smooth surfaced and easy to clean?
-
Are floors designed to support current and future vehicle weight and footprints?
-
To prevent injury are adjacent room floors on the same level plane as the apparatus floor?
-
Do floors have a minimum 1 inch (2.5 cm) to 10 feet (3M) slope to a center line transverse drain collection point?
-
Is the apparatus floor provided with a traverse drain heavy gauge cover, sediment / grease trap?
-
Observer's Comments:
ARFF STATION APRON (AC 150/5210-15)
-
Does the apron / driveway have direct access to the aircraft movement area?
-
Does the apron area have exterior hose bibs with garden hose connections?
-
Are fire hydrants adjacent to the ARFF Station?
-
If wall hydrants are provided, are they corrected labeled?
-
Are pedestrian / vehicle traffic warning lights installed for location where traffic crosses the apron?
-
Observer's Comments:
ARFF STATION APRON STANDARDS (AC 150/5210-15)
-
Is the apron operating surface large enough to allow the longest vehicle access to any apparatus bay?
-
Is the apron at least 28 feet wide?
-
Is the apron length at least 1.5 times the longest vehicle lenght?
-
Are they tapered to not less that 28 feet for multi-vehicle stations?
-
Are they tapered to not less than 12 feet for single-vehicle stations?
-
Is the apron strength that same as the apparatus bay?
-
Gradient - Is the apron slope a minimum of 2 - 4 degrees and is it directed away from the apparatus bays?
-
Marking - Is the floor and apron striping provided? Is it at least 1.5 times the vehicle length for the apron?
-
Lighting - Is exterior lighting provided? Is it mounted to prevent view obstruction?
-
Apron Canopy - Is an apron canopy provided?
-
Are concrete bollards provided on each side of bay doors to prevent structural damage from backing vehicles?
-
Observer's Comments:
ARFF STATION SCBA AND FIRE EXTINGUISHER ROOM (AC 150/5210-15)
-
Is a room dedicated for the servicing and repair of SCBA and Fire Extinguishers?
-
Is the room provided with storage cabinets and a workbench to perform tasks and store materials and parts?
-
Is the space a minimum of 200 square feet?
-
Is an air filtration system available for re-servicing of SCBA?
-
Is an air compressor provided?
-
Is a cascade system used?
-
Are all components properly marked with labels / placards or signs that identify nomenclatures?
-
Are tags and warning labels affixed to equipment for safety operations?
-
Observer's Comments:
ARFF STATION EMERGENCY GENERATOR ROOM (AC 150/5210-15)
-
Is a separate room provided for an emergency generator?
-
Is the generator of sufficient size to support all essential services?
-
Is the room equipped with an exterior access for maintenance and repair work?
-
Is the fuel supply sufficient to operate the generator under maximum load for a minimum 7 day period?
-
Is the room enclosed by fire rated walls and ceiling?
-
Speakers for alarm notification announcements?
-
Observer's Comments:
MISCELLANEOUS OBSERVATION(S) & PHOTO(S)
-
Miscellaneous Observation(s)
-
Miscellaneous Photo(s)
SIGNATURE OF OBSERVER & COMMENTS
-
Observer"s Comments
-
Name & Signature of Observer
-
Date & Time of Observation
-
Date Reviewed By AIR - L thru AIR - LF