Information

  • Audit Title

  • Client / Site

  • Location
  • Prepared by

  • Contact phone number

  • Conducted on

  • Other staff

  • Development Application Number

  • Complying Development Number

  • Construction Certificate Number

Inspection items

  • All works carried out in accordance with development consent

  • Notes

  • Landscaping complete

  • Notes

  • All soffits are installed

  • Notes

  • All remaining stormwater drainage has been connected and functioning

  • Notes

  • Ensure a durable notice has been installed within the meter box or kitchen cupboard

  • Notes

  • Earth around the structure is appropriately graded

  • Notes

  • Council assets have been adequately repaired

  • Notes

  • External colours are per development consent

  • Notes

  • Interior fittings and fixtures complete to an acceptable standard

  • Notes

  • Rooms and space used for approved use under the development consent

  • Notes

  • Photographs

Smoke alarm for class 1a

  • Smoke alarm installed between each part of the dwelling containing bedrooms and the remainder of the dwelling

  • Notes

  • Smoke alarm installed in the hallway wher it serves bedrooms

  • Notes

  • Smoke alarm installed in any other storey not containing bedrooms

  • Notes

  • Photographs

Smoke alarm for class 1b

  • Smoke alarms are installed on or near the ceiling in every bedroom

  • Notes

  • Smoke alarms are installed on or near the ceiling in every corridors or hallway associated with a bedroom, or if there is no corridor or hallway, in an area between the bedrooms and the remainder of the building

  • Notes

  • Smoke alarms are installed on or near the ceiling in each other storey

  • Notes

  • Lighting to assist evacuation incorporated in the smoke alarm or located within the corridor, hallway or area served by the smoke alarm and be activated by the smoke alarm

  • Notes

  • Photographs

Smoke alarm mounting position

  • Wall mounted Smoke alarm is mounted between 300mm and 500mm off the ceiling

  • Notes

  • Cathedral ceiling mounted Smoke alarm is mounted between 500mm and 1500mm off the ceiling

  • Notes

  • Smoke alarms are mounted on exposed floor joists

  • Notes

  • Photographs

Stairs

  • Stair case has no more than 18 and no less than 2 risers

  • Notes

  • Nominal dimension of the goings and risers are constant throughout each stair flight (except winders)

  • Notes

  • Treads are of solid construction if the stairway is more than 10m high or connects more than 3 storeys

  • Notes

  • No more than 3 winders in lieu of each quarter landing or 6 winders in lieu of each half landing

  • Notes

  • Riser openings do not allow a 125mm sphere to pass through

  • Notes

  • Treads have slip resistant finish or suitable non-skid strip near the edge of the nosings

  • Notes

  • Photographs

Stair case landings

  • landings are not less than 750mm long and when involves a change in direction is measured 500mm from the inside edge of the landing, and

  • Notes

  • Gradient is no greater than 1:50, and

  • Notes

  • A landing is provided, when the sill of the threshold of a doorway opens onto a stair that provides a change in floor level or floor to ground level is greater than 3 risers or 570mm

  • Notes

  • Photographs

Going and riser dimensions

  • Risers are no greater than 190mm and no less than 115mm

  • Notes

  • Spiral staircase risers are no greater than 220mm and no less than 140mm

  • Notes

  • Goings are no greater than 355mm and no less than 240mm

  • Notes

  • Spiral staircase goings are no greater than 370mm and no less than 210mm

  • Notes

  • Slope relationship (2R+G) is no greater than 700mm and no less than 550mm

  • Notes

  • Spiral staircase slope relationship (2R+G) is no greater than 700mm and no less than 550mm

  • Notes

  • Photographs

Minimum facilities in a class 1 building

  • Kitchen sink and facilities for the preparation and cooking of food, and

  • A bath or shower, and

  • Clothes washing facilities, comprising of at least one washtub and space in the same room for a washing machine

  • A closet pan and washbasin

  • Notes

  • Photographs

Minimum room heights

  • Habitable rooms have no less than 2.4m (lower projection is permitted subject that it does not interfere with the functioning of the room

  • Corridors passageway or the like are no less than 2.1m

  • Bathroom, laundry, kitchen and the like are no less than 2.1m

  • Stairs are no less than 2.0m when measured from the nosing line

  • Photographs

Visibility of glazing

  • Presence of a glazing in a door, side panel or panel capable of being mistaken for being a doorway or opening is not made apparent is marked and readily visible by the for of an opaque band of no less than 20mm in height and located as follows-

  • Notes

  • Upper edge no less than 700mm above the floor, and

  • The lower edge is no more than 1200mm above the floor

  • Photographs

Balustrades

  • Balustrade heights are a minimum 1000mm above finished floor level

  • Notes

  • No horizontal members between 150mm and 760mm in balustrade with floor level more than 4000mm above ground level directly below the balustrade

  • Notes

  • Balustrade height is no less than 865mm above the nosing on a stair case

  • Notes

  • A 125mm sphere cannot pass any horizontal or vertical element of a balustrade

  • Notes

  • Photographs

Masonry exterior

  • External masonry clean with weepholes free of foreign materials

  • Notes

  • Expansion joints have been installed if required

  • Notes

  • Correct cladding has been installed on the exterior of the structure

  • Notes

  • Damp course remains exposed and not covered in soil

  • Notes

  • Photographs

Light and ventilation

  • Each room has the required 10% light and 5% ventilation

  • Notes

  • Photographs

Bathroom

  • Bathroom fittings and fixtures complete

  • Notes

  • All joins are siliconed with no gaps

  • Notes

  • Mechanical ventilation provided if no natural ventilation available

  • Notes

  • Minimum 1200mm provided from hinge to closet pan or swing out or slide or have lift off hinges with rebate at top of door jamb

  • Notes

  • Photographs

Flashing

  • External flashing completed correctly

  • Notes

  • Photographs

Surface water drainage

  • The external finished surface surrounding the slab is sloped 50mm over 1m from the building

  • Notes

  • Slab height of no less than 100mm above external finished surface level on sandy, well drained areas

  • Notes

  • Slab height of no less than 50mm above external finished surface level that is impermeable

  • Notes

  • 150mm in any other case

  • Notes

  • Photograph

General

  • Outstanding items observed in previous inspections are addressed

  • Notes

  • Development as per the Development Consent

  • Noted unauthorised development

  • Site notes

  • Photograph

Required information to be submitted to council

  • Certificate of installation of the smoke alarm

  • Certificate of installation of all fire rated systems

  • Engineers certificates required from previous inspections

  • Section 73 certificate from Sydney Water

  • Final survey identification report

  • Certificate of installation of the waterproofing in wet areas

  • Certificate of installation of glazing and human impact glazing

  • Works as executed details

  • Part A and Part B termite management certificates

  • Concrete delivery receipts

  • Timber delivery receipts with timber gradings

  • Missed inspection statement

  • Written statement indicating why one or more of the following mandatory inspections was unavoidably misused

  • Other certification

Inspection result

  • Result of the inspection

  • Should you have any enquiries regarding this inspection report please contact Auburn City Council on 9735 1222 or via email council@auburn.nsw.gov.au or in person at the customer service centre located at 1Susan Street, Auburn.

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.