Fire Safety Equipment Audit
-
Site conducted
-
Conducted on
-
Prepared by
-
Location
-
All tests are done in accordance with the Australian Standards as shown below;
AS2444-2001
AS1851-2012
AS4265-1995
AS1841.1-2007
AS/NZS 1850-2009
Prepare for Service Operations
-
Nominated job contact:
-
Phone
-
Reports to:
-
Email
Special Requirements
-
Induction
-
Action taken or comments
-
Work Permit
-
Action taken or comments
-
Sensative Areas
-
Action taken or comments
-
Hazardous Areas
-
Action taken or comments
-
Other
-
Action taken or comments
Service Details
-
Service Areas
- Fire Extinguishers
- Hose Reels
- EM Lighting
- Fire and Smoke Doors
- Hydrants
- Pumpsets
- Sprinkler Systems
- CIE and FIP
- Detectors
- Seals and Collars
Asset Inspection Records<br>Fire Extinguishers
- Fire Extinguishers
-
Asset Number
-
Location
-
Fire Extinguisher Type
- Water
- Wet Chemical
- Foam
- Dry Chemical Powder - ABE
- Dry Chemical Powder - BE
- CO2
- Vapourising Liquid
-
IS this the Annual Level 2 Service?
-
Time how long it takes to discharge extinguisher completely.
-
Did the extinguisher last more than 90 Seconds?
-
-
Weight - Kg/Lt
-
Extinguisher Rating (eg. 4a-40B-E)
-
Pressure Test Date
-
Last Service Level
-
Service Level
-
Easily Accessible
-
Is signage Compliant? ie. not lower than 2m above ground
-
Is the exterior in good condition, with legible Instructions?
-
Is there a compliant service tag?
-
Anti Tamper Seal?
-
Is the Outlet Hose assembly in good condition?
-
Is the Pressure indicator working?
-
Is the support bracket present and secure?
-
Is the weight within the accepted variance? (5% of labelled approx. Gross Mass)
-
Does the Actuating device function?
-
Easily Accessible
-
Is signage Compliant? ie. not lower than 2m above ground
-
Is the exterior in good condition, with legible Instructions?
-
Is there a compliant service tag?
-
Anti Tamper Seal?
-
Is the Outlet Hose assembly in good condition?
-
Is the Pressure indicator working?
-
Is the support bracket present and secure?
-
Is the weight within the accepted variance? (5% of labelled approx. Gross Mass)
-
Does the Actuating device function?
-
-
Easily Accessible
-
Is signage Compliant? ie. not lower than 2m above ground
-
Is the exterior in good condition, with legible Instructions?
-
Is there a compliant service tag?
-
Anti Tamper Seal?
-
Is the Outlet Hose assembly in good condition?
-
Is the Pressure indicator working?
-
Is the support bracket present and secure?
-
Is the weight within the accepted variance? (5% of labelled approx. Gross Mass)
-
Does the Actuating device function?
-
-
Easily Accessible
-
Is signage Compliant? ie. not lower than 2m above ground
-
Is the exterior in good condition, with legible Instructions?
-
Is there a compliant service tag?
-
Anti Tamper Seal?
-
Is the Outlet Hose assembly in good condition?
-
Is the Pressure indicator working?
-
Is the support bracket present and secure?
-
Is the weight within the accepted variance? (5% of labelled approx. Gross Mass)
-
Does the Actuating device function?
-
Pass or Fail? If fail, provide details
Asset Inspection Records<br>Fire Blankets
- Fire Blankets
-
Asset Number
-
Location
-
Equipment Brand and Size
-
Last Service Level
-
Service Type
-
Check for compliant Signage
-
Check Package is in tact, and in good condition
-
Check Tabs are properly attached
-
Check condition of blanket
-
Is a compliant tag attached?
-
Check for compliant Signage
-
Check Package is in tact, and in good condition
-
Check Tabs are properly attached
-
Check condition of blanket
-
Is a compliant tag attached?
-
Result
-
Details
Asset Inspection Records<br>Fire Hose Reels
- Fire Hose Reels
-
Asset Number
-
Location
-
Equipment Type
- 19mm
- 25mm
- 30m
- 36m
-
Last Service Level
-
Service Level
-
Is hose in good working order?<br>Hose Reel<br>Full length of Hose<br>Interlock Device and Nozzle<br>Water Shut Off Valve
-
What has not operated as designed?
- Hose Reel
- Full lenght of Hose Reel
- Interlock Device
- Nozzle
- Water Shut Off Valve
- Cabinet (If applicable)
- Hose Fitting
- Swing Arm
- Hose Guide
- Anchor Points
- Bearings
-
Flow Rate (Litres / Second)
-
Is hose in good working order?<br>Hose Reel<br>Hose Fitting<br>Full length of Hose<br>Interlock Device and Nozzle<br>Water Shut Off Valve<br>Swing Arm<br>Hose Guide<br>Anchor Points<br>Bearings
-
What has not operated as designed?
- Hose Reel
- Full lenght of Hose Reel
- Interlock Device
- Nozzle
- Water Shut Off Valve
- Cabinet (If applicable)
- Hose Fitting
- Swing Arm
- Hose Guide
- Anchor Points
- Bearings
-
Flow Rate (Litres / second)
-
Is hose in good working order?<br>Hose Reel<br>Hose Fitting<br>5m of Fire Hose<br>Interlock Device and Nozzle<br>Water Shut Off Valve<br>Swing Arm
-
What has not operated as designed?
- Hose Reel
- 5m of Fire Hose
- Interlock Device
- Nozzle
- Water Shut Off Valve
- Cabinet (If applicable)
- Swing Arm
- Hose Fitting
-
-
Pass or Fail
-
Comments
Flow Rate of Most Disadvantaged Hose Reel
-
ID
-
Location
-
Flow Rate (Litres per Second)
Emergency and Exit Lighting
- Emergency and Exit Lighting
-
Asset Number
-
Location
-
Make
-
Model
-
Date Installed
-
Date LSL
-
Type
-
Maintianed
-
Lamp Type
-
Test Facility
-
Maintained
-
Illumination Type
-
Lamp Type
-
Test Facility
-
Visual Ispection
-
Test Start
-
Test Finish
-
Pass Or Fail
-
Photo
Emergency Lighting Records
-
Service and maintenance records
-
Emergency luminaire, exit and directional signs
-
Exit and directional signs-Direction to a required exit
-
Exit and directional signs—Sensors or other controls
-
Requirements for exit signs
-
Automatic test systems, control and indicating equipment—Condition
-
Emergency luminaire and exit signs—initiate duration test
-
Defined service life
-
Check each initiated discharge system is reverted to normal operation
-
Check externally illuminated exit sign. Greater than 200 lx is required on face
-
Indirect lighting systems—Reflecting surfaces (where fitted)
-
Directional beam luminaries (where fitted)
-
Normal lighting and emergency operation relationship
-
Emergency luminaire and exit signs—Tubular fluorescent lamps
-
Exit signs—Performance reduction through light emission depreciation
-
Exit signs—Externally illuminated
-
LSL (end of light source life)
-
Survey—Emergency light and exit sign schedule
-
Survey—Fire control centre (where fitted)
-
Survey—Emergency Luminaires
-
Survey—Exit and directional signs
-
LED-maintained emergency luminaires—Performance reduction through light emission depreciation
Outstanding defects for all equipment
-
Are there Outstanding Defects
Outstanding Defects
-
Asset No
-
Equipment Type
-
Defect Description
-
Defect Type Critical/Non-critical Non-conformance
-
Comments