Information
-
Document No.
-
Audit Title
-
Client / Site
-
Conducted on
-
Prepared by
-
Location
-
Personnel
-
-
Site address
-
Region
-
Contractor/s / Staff onsite
-
Job Description
-
Date
-
Time
1. Site Risk Management
-
Are relevant work instructions available and a Site Risk Assessment completed for the work?
-
Has the JSA/site risk assessment identified site specific risks, been signed and dated by all crew members and have SWMS/ WI for task been identified?
-
Are all identified risk control measures on JSA/site risk assessment in place?
-
Have sub-contractors, site visitors been inducted onto the site and signed onto the Risk Assessment?
-
Has the relevant Traffic/Pedestrian Management Plan been identified/created and available on site and documented on the JSA?
-
Overall, is the site risk assessment/ JSA adequate for the worksite?
2. Skills and Competency
-
Do all personnel have COCs on site?
-
Are the COCs current?
-
Are COCs relevant for the task at hand?
-
Do subcontractors hold appropriate qualifications?
3. Forms/Documentation
-
Is there a job pack available on site?
-
Does the job pack contain an approved and relevant scope/ methodology in line with approved standards?
-
Does the job pack contain site specific Dial before You Dig / utility plans information?
-
Is a strategic or transmissions pipelines work permit required and are there any restrictions - are they being followed?
-
Is a sub trans or power pole permit required and available - is it valid and the restrictions being adhered to?
-
Are any other permits to work required and onsite - eg confined space, non routines, etc...?
-
Is a CAR/ WAP required and is it on site and in date?
-
Does the excavation require a hazardous works notification for depth/ shoring - and have Work Safe been notified?
-
Are MSDS available on site for all chemicals/fuels?
4. Traffic and Pedestrian Management
-
Has the appropriate Traffic and Pedestrian Management Plan been identified, and does it meet all requirements?
-
Does the actual traffic/pedestrian layout reflect the Traffic/Pedestrian Management Plan?
-
Is pedestrian traffic safely controlled through the worksite?
-
Are traffic signs and devices legible and undamaged?
-
Are suitable barriers provided to protect the public from the work site?
-
Where site is to be left overnight, are adequate protection measures, lighting and night guidance provided?
5. Personnel Protective Equipment
-
Is PPE in accordance with GSD PPE matrix?
-
Is required PPE within inspection or replacement dates?
-
Is other appropriate PPE utilised as required and in good condition? (E.g. Harness, Life lines)?
-
Is PPE in an adequate condition?
6. Vehicles/Plant
-
Are all plant operators licensed as required?
-
Are logbooks available for all plant on site and have they been maintained appropriately?
-
Have pre-start checklists been completed?
-
Are all vehicles on site registered?
-
Are all vehicles/plant within their service range?
-
What is the general condition of the vehicles/plant (cleanliness)?
-
Is all equipment carried on vehicles adequately secured?
-
Is there appropriate identification / branding on contractor vehicles?
7. First Aid
-
Is there an intact First Aid kit?
-
Is the kits location marked on the vehicle?
-
Do the contents appear to be complete, in good condition and within expiry dates?
8. Gas Escape/Outage Management
-
Is the Service Providers level of response consistent with emergency protocols under the conditions observed on site?
-
Have personnel attended to the outage within the guidelines of the response times?
-
Has the service provider isolated the area required?
-
Has the Service Provider assessed the number of customers effected?
-
Has service provider turned off effected customers?
-
Is there evidence of a satisfactory area covered for leakage location and identification?
-
Have all other utilities assets been located/proved prior to excavation?
9. Tools and Equipment: Testing and Condition
-
Are all electrical tools, generators, leads, RDCs tagged and within their test date range?
-
Is Poly Fusion equipment within calibration dates?
-
Is the gas detector within calibration date?
-
Are Oxygen analysers within calibration date?
-
Is voltage tester fit for purpose and tested prior to use?
-
Is fire extinguisher charged and in test date?
10. Worksite/Work Practices
-
Is appropriate number of trained and competent crew members on site for task?
-
Effective Spotter/Safety Observers in place?
-
Are cross bonding leads required and used?
-
Are the appropriate numbers of fire extinguisher/s on site and placed in appropriate locations?
-
Have all utilities been located and /or exposed by hand prior to mechanical excavation and/ or cross over ?
-
Are jointing techniques in line with Electrix WIs?
-
Have Electrix standards (including covers, clearances, offsets and bedding materials) been maintained?
-
Is the site tidy with no obvious tripping or other hazards?
-
Are trenches appropriately battered/shored?
-
Is spoil placed in excess of 0.5 from excavation wall?
-
Is Sleeve/Slabbing/tape protection in place?
-
Has pressure testing and purging been conducted in line with purging procedure or Electrix WIs?
-
Does reinstatement and compaction meet Council and property owners requirements?
11. Environment and Hazardous Goods
-
Does the Hazard ID identify environmental risks and controls?
-
Have the appropriate controls been put in place on site?
-
Are erosion and/or sediment control structures located between source (i.e. spoil) and receptor (i.e. drain)?
-
Is noisy plant and machinery switched off when not in use?
-
Are dust generating activities (i.e. concrete cutting), being managed correctly i.e. water hoses attached to cutting equipment?
-
Are the drip lines of any trees on site free of large/heavy equipment?
-
If applicable, have tree roots been clean cut at a 45 degree angle and not torn?
-
Have trees been identified and work within their proximity approved by an arborist report?
12 Housekeeping
-
Has debris or rubbish been controlled and removed from site?
-
Has contact been made with the customer/ site contact prior to works commencing?