Title Page
-
Machine
-
Serial Number
-
Conducted on
-
Undertaken by
-
Location
Safety Checks
Cut Buttons
-
Guillotine should only strike on when both cut buttons are depressed within 0.5 sec of each other.
-
Guillotine should not strike on when each control is operated independently and reset in turn.
-
Guillotine should not strike on when one cut button is operated followed by the other after 2-3 seconds delay.
-
Guillotine should not strike on when cut buttons are operated within 0.5 sec but if one is released mid-way through the stroke and re-operated.
Light Barrier
-
Is the guard indicator operating correctly (where fitted)?
-
Is the recommended test piece detected (3 places)?
-
Does the knife and clamp stop when the light barrier is interrupted during stroke.
-
Is the fixed rear table guarding fitted and secured or does the interlocked access gate prevent powered knife and clamp movement?