Title Page

  • Conducted on

  • Prepared by

  • Property address

Hallway

Means of escape

  • Within max length

  • Clear of any furniture/coat hooks

  • Clear of any tenants items

  • Clear of any combustibles

  • Any trailing leads/trip hazards

  • Any overloading of electrical circuits

  • Grade A fire alarm panel

  • Detector and sounder

  • Manual call point

  • Emergency lighting

  • Keyless exit

  • If gas/electric meter in escape route are they protected in 30min fire resistant material

  • Walls/ceiling coverings suitable

  • Additional hazards

Fire door to under stairs cupboard

  • Self closing

  • 3 fire rated hinges

  • Latching

  • Gaps 3mm head and sides

  • Gap under 9mm under door

  • Strips and seal present and undamaged

  • Under stairs fire boarded

Fire door to basement

  • Self closing

  • 3 fire rated hinges

  • Latching

  • Gaps 3mm head and sides

  • Gap under 9mm under door

  • Strips and seal present and undamaged

Stairs and first floor landing

Means of escape

  • Within max length

  • Clear of any furniture/coat hooks

  • Clear of any tenants items

  • Clear of any combustibles

  • Any trailing leads/trip hazards

  • Any overloading of electrical circuits

Stairs and second floor landing

Means of escape

  • Within max length

  • Clear of any furniture/coat hooks

  • Clear of any tenants items

  • Clear of any combustibles

  • Any trailing leads/trip hazards

  • Any overloading of electrical circuits

  • Grade A fire alarm panel

  • Detector and sounder

  • Manual call point

  • Emergency lighting

  • Keyless exit

  • If gas/electric meter in escape route are they protected in 30min fire resistant material

  • Walls/ceiling coverings suitable

  • Additional hazards

Bedroom 1

Fire door

  • Self closing

  • 3 fire rated hinges

  • Latching

  • Gaps 3mm head and sides

  • Gap under 9mm under door

  • Strips and seal present and undamaged

  • Key less exit

  • Interlinked smoke alarm

  • Over door hangers/doors propped open/coat hooks on door

  • Any risk of falls - are there restrictors on window

  • Any portable heaters

  • Are electrical circuits free of evidence of overloading/no trailing leads

  • All electricals kept away from combustible materials

If bedroom has requirement to pass through high risk room

  • Fire escape plan on display

  • Fire escape sticker on window

  • Height and size of escape window adequate

  • Length of escape route within limit

  • Escape route away from property unobstructed

Bedroom 2

Fire door

  • Self closing

  • 3 fire rated hinges

  • Latching

  • Gaps 3mm head and sides

  • Gap under 9mm under door

  • Strips and seal present and undamaged

  • Key less exit

  • Interlinked smoke alarm

  • Over door hangers/doors propped open/coat hooks on door

  • Any risk of falls - are there restrictors on window

  • Any portable heaters

  • Are electrical circuits free of evidence of overloading/no trailing leads

  • All electricals kept away from combustible materials

If bedroom has requirement to pass through high risk room

  • Fire escape plan on display

  • Fire escape sticker on window

  • Height and size of escape window adequate

  • Length of escape route within limit

  • Escape route away from property unobstructed

Bedroom 3

Fire door

  • Self closing

  • 3 fire rated hinges

  • Latching

  • Gaps 3mm head and sides

  • Gap under 9mm under door

  • Strips and seal present and undamaged

  • Key less exit

  • Interlinked smoke alarm

  • Over door hangers/doors propped open/coat hooks on door

  • Any risk of falls - are there restrictors on window

  • Any portable heaters

  • Are electrical circuits free of evidence of overloading/no trailing leads

  • All electricals kept away from combustible materials

If bedroom has requirement to pass through high risk room

  • Fire escape plan on display

  • Fire escape sticker on window

  • Height and size of escape window adequate

  • Length of escape route within limit

  • Escape route away from property unobstructed

Bedroom 4

Fire door

  • Self closing

  • 3 fire rated hinges

  • Latching

  • Gaps 3mm head and sides

  • Gap under 9mm under door

  • Strips and seal present and undamaged

  • Key less exit

  • Interlinked smoke alarm

  • Over door hangers/doors propped open/coat hooks on door

  • Any risk of falls - are there restrictors on window

  • Any portable heaters

  • Are electrical circuits free of evidence of overloading/no trailing leads

  • All electricals kept away from combustible materials

If bedroom has requirement to pass through high risk room

  • Fire escape plan on display

  • Fire escape sticker on window

  • Height and size of escape window adequate

  • Length of escape route within limit

  • Escape route away from property unobstructed

Bedroom 5

Fire door

  • Self closing

  • 3 fire rated hinges

  • Latching

  • Gaps 3mm head and sides

  • Gap under 9mm under door

  • Strips and seal present and undamaged

  • Key less exit

  • Interlinked smoke alarm

  • Over door hangers/doors propped open/coat hooks on door

  • Any risk of falls - are there restrictors on window

  • Any portable heaters

  • Are electrical circuits free of evidence of overloading/no trailing leads

  • All electricals kept away from combustible materials

If bedroom has requirement to pass through high risk room

  • Fire escape plan on display

  • Fire escape sticker on window

  • Height and size of escape window adequate

  • Length of escape route within limit

  • Escape route away from property unobstructed

Bedroom 6

  • Is there 6th bedroom

Fire door

  • Self closing

  • 3 fire rated hinges

  • Latching

  • Gaps 3mm head and sides

  • Gap under 9mm under door

  • Strips and seal present and undamaged

  • Key less exit

  • Interlinked smoke alarm

  • Over door hangers/doors propped open/coat hooks on door

  • Any risk of falls - are there restrictors on window

  • Any portable heaters

  • Are electrical circuits free of evidence of overloading/no trailing leads

  • All electricals kept away from combustible materials

If bedroom has requirement to pass through high risk room

  • Fire escape plan on display

  • Fire escape sticker on window

  • Height and size of escape window adequate

  • Length of escape route within limit

  • Escape route away from property unobstructed

Bedroom 7

  • Is there 7th bedroom

Fire door

  • Self closing

  • 3 fire rated hinges

  • Latching

  • Gaps 3mm head and sides

  • Gap under 9mm under door

  • Strips and seal present and undamaged

  • Key less exit

  • Interlinked smoke alarm

  • Over door hangers/doors propped open/coat hooks on door

  • Any risk of falls - are there restrictors on window

  • Any portable heaters

  • Are electrical circuits free of evidence of overloading/no trailing leads

  • All electricals kept away from combustible materials

If bedroom has requirement to pass through high risk room

  • Fire escape plan on display

  • Fire escape sticker on window

  • Height and size of escape window adequate

  • Length of escape route within limit

  • Escape route away from property unobstructed

Bedroom 8

  • Is there 8th bedroom

Fire door

  • Self closing

  • 3 fire rated hinges

  • Latching

  • Gaps 3mm head and sides

  • Gap under 9mm under door

  • Strips and seal present and undamaged

  • Key less exit

  • Interlinked smoke alarm

  • Over door hangers/doors propped open/coat hooks on door

  • Any risk of falls - are there restrictors on window

  • Any portable heaters

  • Are electrical circuits free of evidence of overloading/no trailing leads

  • All electricals kept away from combustible materials

If bedroom has requirement to pass through high risk room

  • Fire escape plan on display

  • Fire escape sticker on window

  • Height and size of escape window adequate

  • Length of escape route within limit

  • Escape route away from property unobstructed

Bedroom 9

  • Is there 9th bedroom

Fire door

  • Self closing

  • 3 fire rated hinges

  • Latching

  • Gaps 3mm head and sides

  • Gap under 9mm under door

  • Strips and seal present and undamaged

  • Key less exit

  • Interlinked smoke alarm

  • Over door hangers/doors propped open/coat hooks on door

  • Any risk of falls - are there restrictors on window

  • Any portable heaters

  • Are electrical circuits free of evidence of overloading/no trailing leads

  • All electricals kept away from combustible materials

If bedroom has requirement to pass through high risk room

  • Fire escape plan on display

  • Fire escape sticker on window

  • Height and size of escape window adequate

  • Length of escape route within limit

  • Escape route away from property unobstructed

Bedroom 10

  • Is there 10th bedroom

Fire door

  • Self closing

  • 3 fire rated hinges

  • Latching

  • Gaps 3mm head and sides

  • Gap under 9mm under door

  • Strips and seal present and undamaged

  • Key less exit

  • Interlinked smoke alarm

  • Over door hangers/doors propped open/coat hooks on door

  • Any risk of falls - are there restrictors on window

  • Any portable heaters

  • Are electrical circuits free of evidence of overloading/no trailing leads

  • All electricals kept away from combustible materials

If bedroom has requirement to pass through high risk room

  • Fire escape plan on display

  • Fire escape sticker on window

  • Height and size of escape window adequate

  • Length of escape route within limit

  • Escape route away from property unobstructed

Bedroom 11

  • Is there 11th bedroom

Fire door

  • Self closing

  • 3 fire rated hinges

  • Latching

  • Gaps 3mm head and sides

  • Gap under 9mm under door

  • Strips and seal present and undamaged

  • Key less exit

  • Interlinked smoke alarm

  • Over door hangers/doors propped open/coat hooks on door

  • Any risk of falls - are there restrictors on window

  • Any portable heaters

  • Are electrical circuits free of evidence of overloading/no trailing leads

  • All electricals kept away from combustible materials

If bedroom has requirement to pass through high risk room

  • Fire escape plan on display

  • Fire escape sticker on window

  • Height and size of escape window adequate

  • Length of escape route within limit

  • Escape route away from property unobstructed

Bedroom 12

  • Is there 12th bedroom

Fire door

  • Self closing

  • 3 fire rated hinges

  • Latching

  • Gaps 3mm head and sides

  • Gap under 9mm under door

  • Strips and seal present and undamaged

  • Key less exit

  • Interlinked smoke alarm

  • Over door hangers/doors propped open/coat hooks on door

  • Any risk of falls - are there restrictors on window

  • Any portable heaters

  • Are electrical circuits free of evidence of overloading/no trailing leads

  • All electricals kept away from combustible materials

If bedroom has requirement to pass through high risk room

  • Fire escape plan on display

  • Fire escape sticker on window

  • Height and size of escape window adequate

  • Length of escape route within limit

  • Escape route away from property unobstructed

Kitchen

Fire door

  • Self closing

  • 3 fire rated hinges

  • Latching

  • Gaps 3mm head and sides

  • Gap under 9mm under door

  • Strips and seal present and undamaged

  • Fire blanket

  • Grade D interlink heat detector

  • Over door hangers/doors propped open

  • Any risk of falls - are there restrictors on windows

  • Any portable heaters

  • Are electrical circuits free of evidence of overloading/no trailing leads

  • All electricals kept away from combustible materials

  • Keyless exit to any door

  • Extractor fan vented to outside

  • 30 litre swing bins for waste

  • Check the correct amenities are available for the number of tenants as below

  • table.JPG

Lounge

Fire door

  • Self closing

  • 3 fire rated hinges

  • Latching

  • Gaps 3mm head and sides

  • Gap under 9mm under door

  • Strips and seal present and undamaged

  • Grade D interlinked smoke alarm

  • Over door hangers/doors propped open

  • Under-stairs cupbard fire boarded and fire door

  • Any risk of falls - are there restrictors on windows

  • Any portable heaters

  • Are electrical circuits free of evidence of overloading/no trailing leads

  • All electricals kept away from combustible materials

  • Key less exit to any door

  • Are any carbon monoxide detectors required

Bathroom 1

  • WC and wash basin in room

  • Shower/bath in same room as WC

  • Radiator or wall mounted electric heater in room

  • Extractor fan

  • No more than 1 floor between all rooms and a shared WC

  • Cleanable surfaces/floor

  • Is bathroom accessed from the kitchen

  • If yes to above, is there a fire door

If bathroom has requirement to pass through high risk room

  • Height and size of escape window adequate

  • Length of escape route within limit

  • Escape route away from property unobstructed

  • Strips and seal present and undamaged

Bathroom 2

  • WC and wash basin in room

  • Shower/bath in same room as WC

  • Radiator or wall mounted electric heater in room

  • Extractor fan

  • No more than 1 floor between all rooms and a shared WC

  • Cleanable surfaces/floor

  • Is bathroom accessed from the kitchen

  • If yes to above, is there a fire door

If bathroom has requirement to pass through high risk room

  • Height and size of escape window adequate

  • Length of escape route within limit

  • Escape route away from property unobstructed

  • Strips and seal present and undamaged

Waste

  • LCC waste and recycling bins present

  • Any build up of waste

Meter Readings

  • Electric reading

  • Gas Reading

HMO documents

  • HMO licence

  • Gas cert

  • EPC

  • Property services

  • Emergency numbers

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.