Title Page

  • Hollowcore Product Type

  • Todays Hollowcore Post Pour Inspection Number

  • Conducted on

  • Inspection By

  • Bed Number

  • Bed ID

  • Casting Date

  • Slab Depth

  • Project Number

  • Drawing Number

  • Slab ID

LENGTH AND CAMBER CHECK

  • hollowcore camber.jpg
  • Actual Length

  • Label Length

  • Actual length within +/- 25mm of Label length?

  • Camber

  • L/300

  • Is the actual Camber <L/300

DIAGONAL CHECK

  • hollowcore diagonal.jpg
  • Diagonal Check 1 Measurement (mm)

  • Diagonal Check Measurement (mm)

  • Are Checks within 10mm of each other to ensure square cut

WIRE POSITION CHECK

  • hollowcore wire position.jpg
  • Are wires within 10mm of reference positions?

  • Is wire flush with end of slab?

  • If the answer to any of the above is NO, report to Foreman as NON-CONFORMANCE

RECOMMENDATIONS

  • Recommendations (if necessary)

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.