  • Did you have an overfeed on opening?

  • Is the plant room from from leaks? - Pipework/Pumps/Valves/Strainers etc

  • Filter 1 - Pressure IN

  • Filter 1 - Pressure OUT

  • Filter 2 - Pressure IN

  • Filter 2 - Pressure OUT

  • PAC dosing operational?

  • UV Status

  • If the UV has failed or has a fault have you raised the free chlorine and reduced the pH as per the UV SOP?

  • GMS Status?

  • Pump duty cycle and satisfactory operation?

  • Granudos Operating Correctly?

  • pH probe condition satisfactory?

  • Chlorine probe condition satisfactory?

  • Ezetrol pH from pre-open sample

  • Have you entered the correct figure for this question? If so please add your actions in the notes.

  • Have you entered the correct figure for this question? If so please add your actions in the notes.

  • Ezetrol actual pH reading? (On display - complete at the same time as the sample is taken)

  • Have you entered the correct figure for this question? If so please add your actions in the notes.

  • Have you entered the correct figure for this question? If so please add your actions in the notes.

  • Ezetrol free chlorine from pre-open sample

  • Have you entered the correct figure for this question? If so please add your actions in the notes.

  • Have you entered the correct figure for this question? If so please add your actions in the notes.

  • Ezetrol actual Free Chlorine reading? (On display - complete at the same time as the sample is taken)

  • Have you entered the correct figure for this question? If so please add your actions in the notes.

  • Have you entered the correct figure for this question? If so please add your actions in the notes.

  • Pool Technical Operator PPE available and in good condition?

  • Emergency eye wash tested and in working order, clean and accessible?

  • Do we need to order chemicals or test tablets?

  • Are the chemicals topped up sufficiently to last the shift and into the next day?

  • Has the pool vac been in overnight?

  • Have you completed the visual safety check of Inlets and Outlets of the pool/s?

  • Filter air release valves on both filters working correctly?

  • Clean face shield with Evans Glass cleaner inside and out

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.