Title Page

  • Site conducted

  • Conducted on

  • Prepared by

  • Location
  • Personal

Fixture Consistency Checklist

Stockroom - Light Duty Shelving

  • Mending plates are installed within 18” from top and bottom of upright and plates added at every 36” in between.

  • Slotted angle bracing is installed along the top of the 14’ closed uprights at the end of LD runs.

  • Slotted angle bracing is removed from the center of runs where there is cotterman ladders.

  • Support strap is installed at front 14’ LD ends.

  • LD anchor clips have 2 screws installed vertically into the upright. Check SR drawings.

  • Light duty anchored per plan. (Seismic or Non-Seismic) - Dust is vacuumed.

  • Wave protectors and rails are installed per plan.

Stockroom - Pallet Racking

  • Racking is anchored per plan. (Seismic and Non-Seismic). Dust is vacuumed.

  • Wide span has all 4 holes anchored per upright.

Montel System

  • Tracks as well as the ramps have been completed grouted and grouted neatly.

  • Rails are clean of debris.

  • Rails are installed with the spec anchors and tapcons. (Seismic or Non-Seismic)

  • Plywood is notched on the backside at every anchor location.

  • All anti-tips installed correctly.

  • Brakes are adjusted and functioning.

  • All systems have been tested and are in good operating condition.

Hardlines

  • All kick plates have been screwed.

  • Reinforced kick plates are installed per plan.

  • HD bumpers are installed and anchored per plan.

  • 4’ End Frames heavy duty stabilizer kits have been installed. 2nd upright to be anchored and block installed underneath bottom rail at first upright.

  • Stabilizer kits are installed on every end frame.

  • Trim lock is installed around all shelf’s and shelf’s are supported.

  • Filler boxes are installed per plan.

  • High walls are all anchored and vacuumed.

  • All trim kits are installed on all wall work and gondolas.

  • High capacity wall work is anchored to floor not to wall.

  • All corner protectors are installed per plan and sleeves are glued.

Softlines

  • All perimeter wall work is installed per plan

  • All high walls are anchored and vacuumed.

  • MAC centers are anchored per plan location.

  • Moveable walls/tables are set per plan.

  • Shoe end frames have shelves installed.

Fitting Room

  • All mirrors and wedge mirrors are installed and siliconed.

  • Benches and modesty base are also siliconed.

  • Door stops and coat hooks are installed per plan.

  • All signage installed per plan.

  • All doors are operable with no binding and are able to latch.

  • Supplied hardware is used on all door hardware. NO SUBSTITUTIONS

  • Stools and furniture are set to plan.

Guest Service/OPU

  • OPU stockroom fixtures are installed per plan.

  • GS desk is installed and all lights are working.

  • License and policy board are installed per plan.

  • Guest Service/OPU signage installed per plan.

  • Registers shrouds have been installed.

Electronics and Entertainment

  • All wood shelves are installed per plan.

  • All tables and consultation desk are set per plan with stools.

Checklanes

  • Check lanes are set and anchored per plan.

  • Red gondolas are anchored.

  • SCO’s and adjacent gondolas are built and set to plan.

Starbucks

Ulta

  • Fins are installed per shade of each. Darkest on the outside to lightest in the middle.

  • All low voltage wires are connected during install.

  • High walls are set to plan.

  • Graphic focal is on site and installed.

  • Called out fixtures are anchored.

Signage

  • All CSE frames are installed per plan.

  • All overhead signs are installed as you complete a department.

  • All fire exit door stickers are installed.

  • Fire extinguisher stickers are installed per plan.

  • MAC center stickers and “question mark” sign are installed.

  • All office signage/off stage signage is installed.

Offices

  • Desks, chairs, workstations, and file cabinets are all installed per plan.

  • Microwave shelf installed per plan.

  • Lounge Millwork is installed and siliconed. <br>

  • Lockers are installed per plan and numbers installed.

  • Trims are installed on lockers.

  • ADA lockers are installed with hardware and stickers per plan.

  • Lactation room chair, millwork, mirror, and signage are installed per plan.

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.