Information

  • Jobsite:

  • Conducted on:

  • Prepared by:

  • Company representative(s) present during assessment:

  • Project scope and general comments:

  • Document No.

Field Supervisor Interview

  • Enter Supervisor's name and time with the Company.

  • a. Able to explain topic of last safety meeting and how presented?

  • b. Can explain safety requirements of General Contractor?

  • c. Able to identify 3 most critical safety issues on current project?

  • d. Knows process of Accident Investigation and follow-up?

  • e. Able to provide full details about last LEI accident on this project?

  • f. Able to explain procedures for an OSHA Inspection?

  • g. OSHA 300A summary posted (February 1 - April 30)?

  • h. OSHA "It's the Law" Poster posted?

  • i. Worker's Compensation Poster posted?

  • j. SDS Manual on site?

  • k. Designated Medical Provider Posters posted?

  • l. Weekly toolbox talks conducted and documented?

  • m. Are Toolbox Talks up to date?

  • n. Exhibits overall good safety attitude?

Employee Interview

  • Enter employee's name, level and time with Company.

  • a. Topic of last safety meeting and 2-3 main points known?

  • b. Three hazards on current job and preventive measures known?

  • c. Employee knows the proper reporting procedures for injury and hazards?

  • d. Employee is wearing proper personal protective equipment (PPE)?

  • e. Employee knows location of LEI Health and Safety Manual and SDS binder?

  • f. JHA's for this project have been reviewed with the employee?

  • g. Employee knows names of Designated Medical Providers?

  • h. Employee knows location of First Aid kit?

  • i. Employee knows safe assembly area in the event of an evacuation?

Site Safety Plan

  • Written safety plan on site?

  • Safety plan is:

  • JHA's on site?

  • JHA's are:

  • JHA's appear to address tasks, hazards, and safety measures being performed.

  • JHA's appear to contain sufficient detail.

  • JHA's have been reviewed with crew.

  • Temporary traffic control plan in place?

  • Plan developed by state certified Traffic Control Supervisor (TCS)?

  • Plan in writing and on site for review?

  • Permit obtained from authority having jurisdiction (CDOT, county, city)?

  • Plan reviewed with crew prior to work?

  • Work zone appears to be set up per MUTCD standards?

  • Work zone appears to be set up per Method of Handling Traffic (MHT)?

  • Flaggers are state certified, wearing appropriate PPE, and using proper STOP/SLOW paddle?

General and Emergency Safety Provisions

  • Water and restroom facilities available?

  • Is there an adequate supply of potable water provided?

  • Adequate lighting provided?

  • First aid kits available and stocked?

  • First Aid Kits easily accessible?

  • Blood borne Pathogen (BBP) kit available?

  • Is there a FA/CPR/AED certified person on site if medical services are not available within 4 minutes?

  • Fire extinguishers available on each floor and near flammable liquids in storage or in use.

  • Fire extinguishers appear functional, free of damage, and tagged to confirm annual inspection within the last 12 months.

  • Emergency exit routes established and identified?

  • Temporary exit routes are identified through arrows or signage.

  • Other General and Emergency Safety comments.

  • Non LEI - General and Emergency Safety concerns

Housekeeping

  • Aisles/walkways/exit routes clear of trash/debris/other obstructions?

  • Debris picked up. Work area free of trip hazards.

  • Waste containers provided and being used?

  • Floor holes guarded or provided with secure labeled covers?

  • Potential impalement hazards from protruding rebar, form stakes, pipe stubs and nails capped or covered?

  • Protected from projecting nail points (removed/bent over?

  • Materials properly stored?<br> - Materials clear of stairways and exit routes<br> - 4:1 maximum stack height to base ratio<br>- stored away from edges

  • Extension cords/hoses properly protected from sharp edges?

  • Is perimeter protection in place?

  • Floor opening to lower level have toe boards?

  • "Danger - Do Not Use" tags on site?

  • Other Housekeeping observations or comments.

  • Non LEI - Housekeeping observations or comments.

Hazard Communication

  • Are chemicals stored in original or approved containers and properly labeled?

  • Are employees trained on GHS requirements?

  • SDS's on site for chemicals present?

  • Chemicals properly stored (appropriate containers, flammables clear of ignition sources, etc.)?

  • Non LEI Hazard Communication observations or comments?

Electrical

  • Energized electrical panels and equipment fully enclosed?

  • Are energized electrical rooms/panels locked and have proper signage?

  • Are electrical enclosures (switches, receptacles, junction boxes) protected with tight fitting covers or plates?

  • Circuit breakers properly identified (labeled)?

  • Temporary power GFCI protected?

  • Temporary lighting protected from damage by bulb cages/guards or adequate distance?

  • Temporary lighting circuits separate from non-lighting receptacle circuits?

  • Extension cords appear to be in serviceable condition.

  • Electrical cords are proper size of wire?

  • Electrical cords secured off the floor with non-conductive means?

  • Lockout/tagout devices are available?

  • Lockout/tagout devices are used?

  • Is energized work anticipated?

  • Other electrical observations or concerns?

  • Other electrical observations or concerns?

  • Other electrical observations or concerns?

  • Non LEi Electrical observations or concerns?

Personal Protective Equipment

  • Eye protection

  • Eye protection usage policy:

  • Eye protection worn as required?

  • PPE appears to meet ANSI Z87 requirements and is in serviceable condition?

  • Head Protection

  • Head protection usage policy:

  • PPE worn as required?

  • PPE appears to be in serviceable condition?

  • PPE is worn correctly (suspension in the proper direction, no ball caps under hard hat, etc.)?

  • Foot Protection

  • Footwear usage policy:

  • Footwear worn as required?

  • Footwear appears to be in serviceable condition?

  • High Visibility Clothing

  • High visibility clothing usage policy:

  • ANSI rating?

  • High visibility clothing worn as required?

  • High visibility clothing appears to be in serviceable condition (clean, zipped up, etc.)

  • Hand Protection

  • Hand protection usage policy:

  • Hand protection worn as required?

  • Hearing Protection

  • Hearing protection usage policy:

  • Noise monitoring assessment has been performed to determine worker exposure.

  • Noise monitoring should be performed to assess average noise exposures to workers over an 8-hour time-weighted average.

  • Assessment found noise exposures to be:

  • Hearing protection appears to be appropriate for the exposure and worn properly?

  • Employees have been trained on when and how to use hearing protection?

  • Respiratory Protection

  • Respirator usage is voluntary.

  • Air monitoring has been conducted to assess the need, or lack of need, for mandatory respiratory protection?

  • Air monitoring should be performed to assess average exposures to workers over an 8-hour time-weighted average in order to determine if respiratory protection should be required or left optional.

  • Voluntary respirator use limited to filtering face piece respirators (disposable dust masks)?

  • Voluntary use of tight fitting respirators (half-mask and full-mask respirators) other than filtering facepiece respirators (dust masks) requires implementation of those elements of a written respiratory protection program necessary to ensure that the employee using a respirator voluntarily is medically able to use that respirator, and that the respirator is cleaned, stored, and maintained so that its use does not present a health hazard to the user.

  • Voluntary use respirators are NIOSH approved?

  • Workers who wear filtering face piece respirators voluntarily have received Appendix D of OSHA's respiratory protection standard.

  • Respirator use is mandatory.

  • Respiratory hazard requiring protection:

  • Air monitoring has been conducted to assess and quantify hazard and to select appropriate respiratory protection?

  • Air monitoring should be performed to assess average exposures to workers over an 8-hour time-weighted average in order to determine if respiratory protection is required and if so, what type.

  • Written respiratory protection program in place.

  • If operations expose employees to atmospheres containing potentially dangerous concentrations of airborne contaminants (dust, chemical vapors/mists, fumes, etc.), respiratory protection may be required. LEI has a formal respiratory protection program containing the following elements:

    - Procedures for selecting respirators for use in the workplace.
    -Medical evaluations of employees required to use respirators.
    -Fit testing procedures for tight-fitting respirators.
    -Procedures for proper use of respirators in routine and reasonably foreseeable emergency situations.
    -Procedures and schedules for cleaning, disinfecting, storing, inspecting, repairing, discarding, and otherwise maintaining respirators.
    -Procedures to ensure adequate air quality, quantity, and flow of breathing air for atmosphere-supplying respirators.
    -Training of employees in the respiratory hazards to which they are potentially exposed during routine and emergency situations.
    -Training of employees in the proper use of respirators, including putting on and removing them, any limitations on their use, and their maintenance.
    -Procedures for regularly evaluating the effectiveness of the program.

  • Workers required to wear respirators have been medically evaluated.

  • Workers required to wear respirators have been fit tested.

  • All respirators are NIOSH approved?

  • Respirators in use:

  • Respirators in use: N99 - Non-oil particulate - 99% efficient

  • Respirators in use: N95 - Non-oil particulate - 95% efficient

  • Respirators in use: R95 - Up to 8 hours with oil based particulates - 95% efficient

  • Respirators in use: R99 - Up to 8 hours with oil based particulates - 99% efficient

  • Cartridges in use: Magenta - HEPA (P100 - 99.97% efficient)

  • Cartridges in use: Black - organic vapor

  • Cartridges in use: White - acid gas

  • Cartridges in use: Yellow - organic vapor and acid gas

  • Cartridges in use: Olive - mercury vapor and chlorine

  • Cartridges in use: Green - ammonia and methylamine.

  • Cartridges in use: Other

  • Other cartridges in use:

  • Respirators and cartridges (if applicable) are appropriate for the hazard?

  • Other PPE concerns or comments.

  • Workers who voluntarily wear filtering facepiece respirators (dust masks) should be provided with a copy of the information below.

    29 CFR 1910.134 - Appendix D - Information for Employees Using Respirators When Not Required

    Respirators are an effective method of protection against designated hazards when properly selected and worn. Respirator use is encouraged, even when exposures are below the exposure limit, to provide an additional level of comfort and protection for workers. However, if a respirator is used improperly or not kept clean, the respirator itself can become a hazard to the worker. Sometimes, workers may wear respirators to avoid exposures to hazards, even if the amount of hazardous substance does not exceed the limits set by OSHA standards. If your employer provides respirators for your voluntary use, of if you provide your own respirator, you need to take certain precautions to be sure that the respirator itself does not present a hazard.

    You should do the following:

    1. Read and heed all instructions provided by the manufacturer on use, maintenance, cleaning and care, and warnings regarding the respirators limitations.

    2. Choose respirators certified for use to protect against the contaminant of concern. NIOSH, the National Institute for Occupational Safety and Health of the U.S. Department of Health and Human Services, certifies respirators. A label or statement of certification should appear on the respirator or respirator packaging. It will tell you what the respirator is designed for and how much it will protect you.

    3. Do not wear your respirator into atmospheres containing contaminants for which your respirator is not designed to protect against. For example, a respirator designed to filter dust particles will not protect you against gases, vapors, or very small solid particles of fumes or smoke.

    4. Keep track of your respirator so that you do not mistakenly use someone else's respirator.

  • Other PPE observations or comments?

  • Non LEI PPE observations or comments?

Ladders

  • Ladders

  • Ladders are of appropriate duty rating for the task?

  • For construction operations, all ladders should be either Type 1, Type 1A, or Type 1AA

    Ladder Type Rated Capacity Duty Rating Description

    Type IAA Ladder 375 lb. Extra-heavy-duty industrial ladder
    Type IA Ladder 300 lb. Heavy-duty industrial ladder
    Type I Ladder 250 lb. Heavy-duty industrial ladder
    Type II Ladder 225 lb. Medium-duty commercial ladder
    Type III Ladder 200 lb. Light-duty household ladder

  • Ladders are of proper type and size for the task?

  • Ladders appear to be in serviceable condition?

  • Ladders set up correctly (4:1 ratio, 36" extension past upper landing, etc)?

  • Ladder access kept clear at all times?

  • Damaged ladders are tagged and taken out of service?

  • Do ladders have legible safety instructions/load capacity/danger and caution stickers?

  • Ladders or stairs provided at points of access where a break in elevation of 19 inches or more exists?

  • Other ladder concerns?

  • Non LEI Ladder observations or comments.

Scaffolds

  • Scaffolds on site.

  • Are scaffolds erected on level, stable ground with dry footing?

  • Firm footing, mud sills, and base plates in place?

  • Mobile scaffold equipped with locking casters?

  • Casters (if used) are locked while scaffold is in use?

  • Scaffold is plumb, square, and level.?

  • Cross braces are complete?

  • Working levels are fully planked?

  • Planks either overlap support 6-12" or are cleated to restrain from sliding (6-18" if planks are over 10')?

  • Plank deflection does not exceed 1/60 of the plank length, indicating overload. (1" deflection per 5' feet of plank length)?

  • Planking is in serviceable condition (free of checks, notches, saw cuts, excessive splits, etc.)?

  • Front edge of platforms are no further than 14" from face of wall (18" for plastering operations)?

  • Complete guardrail system around working platform (guardrail, intermediate rails, toe boards in place?

  • Scaffold access and egress is provided and adequate where platform is more than two feet above or below access point?

  • If height is over 4 times the narrowest base dimension, scaffold is tied/braced to the wall?

  • Scaffold ties installed per manufacturer spec or every 26 feet vertically and every 30 feet horizontally?

  • Proper bracing pins (no wire, nails, etc.) used in all connections?

  • Scaffolding tagged and inspected daily?

  • Scaffolds with cantilevered work platforms are tied, braced, or outrigged to prevent tipping?

  • Cantilevered work platforms are used to support workers only and not to store/stage materials?

  • Fall protection over 10 feet is provided via guardrails or PFAS's?

  • Other scaffold concerns?

  • Non LEI Scaffold observations or comments?

Powered Mobile Scaffolds (Scissor Lifts)

  • Powered Mobile Scaffolds (Scissor Lifts).

  • Lift operators have received training on proper operation and capacity?

  • Is fall protection required per GC or internal policy?

  • Is employee wearing full body harness with lanyard attached to designated anchor point in the basket?

  • Working platform is clear of trip hazards?

  • Access gate/chain is closed while lift is in use?

  • Are reverse signal alarms and horn (audible) functioning?

  • Other scissor lift comments or observations?

  • Non LEI Scissor lift observations or comments?

Working at Heights

  • Workers more than 6' above a lower level?

  • PFAS?

  • Anchors appear adequate and/or properly installed?

  • Employees are tied-off to proper anchorage points?

  • Lifelines in good condition and adjusted to restrain or limit free fall to 6 feet?

  • Lanyards in good condition and properly connected?

  • Harnesses in good condition and properly adjusted?

  • Harnessed have D-rings in center of back?

  • Is fall protection equipment inspected prior to use?

  • Guardrails

  • Rails are complete along fall hazard?

  • Safety guardrails/cables are secured properly?

  • Appear to be installed to withstand 200 pounds downward and outward force?

  • 42" top rails (+/-3 ") and mid rails approximately halfway between the working surface and the top rail?

  • Midrail height does not exceed 21"?

  • Wire rope top rails flagged ever 6' with high-visibility material?

  • Guardrails do not pose puncture/laceration/snagging hazards?

  • Toe boards are in place as needed to protect workers below from falling objects?

  • Wall openings less than 39 inches high are guarded?<br>("Openings" are over 18" wide and over 30" high)

  • Is guardrailing provided on ramps?

  • Are guardrails or handrails installed at stairs and landings?

  • Warning lines (For roofing operations on low-slope (4:1) roofs only)

  • Warning lines complete around unprotected roof edge?

  • Warning lines no closer than 6 feet from roof edge?<br>(10 feet if mechanical equipment is used perpendicular to warning line)

  • Access point is blocked off by rope, chain, or other barricade, or the path is offset to avoid walking directly into the work area?

  • Lines between 34 and 39 inches?

  • Workers between line and roof edge protected by PFAS or safety monitor?

  • Safety monitor (Roofing operations or as part of a site-specific Fall Protection Plan only)

  • Monitor is on same working level as workers, within sight distance, and close enough to communicate?

  • Monitor warns workers when back is to roof edge or worker is piling material in direction of roof edge?

  • Monitor has no other duties to distract from monitoring workers?

  • Controlled Access Zone (Overhand bricklaying or as part of a site-specific Fall Protection Plan only)

  • General operations - Control line is 6 - 25 feet from unprotected edge?

  • Precast Erection Operations - Control line is 6 - 60 feet or 1/2 the length of the member being erected?

  • Overhand Bricklaying - Control line is 10 - 15 feet from unprotected edge?

  • Control line extends along entire length of unprotected edge and connects to guardrails or walls?

  • Control line is flagged every 6 feet and has at least 200 pound breaking strength?

  • Control line is 39 - 45 inches high?

  • Site-specific Fall Protection Plan (For leading edge, precast concrete, and residential construction only)

  • Conventional fall protection methods have been demonstrated to be infeasible and documented in safety plan?

  • Plan is in writing and on site for review?

  • Plan includes discussion of measures to be taken to protect workers who cannot use conventional fall protection methods?

  • Plan includes names of workers included under the plan?

  • Plan lists each location that conventional fall protection cannot be used. Locations are classified as Controlled Access Zones?

  • Steel erection fall protection

  • Steel erectors protected at heights over 15 feet. Fall protection required for 15' or greater?

  • Connectors protected at heights over 30 feet.?

  • Controlled Decking Zone (CDZ) in use?

  • Used in area between 15 and 30 feet above lower level where leading edge decking is being installed?

  • Access to CDZ limited to leading edge workers?

  • CDZ boundaries designated and marked?

  • CDZ is no more than 90 feet wide and no more than 90 feet from leading edge?

  • Warning line stanchions appear capable of resisting 16 pound force applied 30 inches up?

  • Other Fall protection concerns or comments?

  • Non LEi Fall protection concerns or comments?

Hand and power tools

  • Hand and power tools

  • Hand tools in serviceable condition?

  • Are hand tools inspected regularly?

  • Tool cords/plugs in good condition?

  • Power tools properly guarded and free of damage?

  • Power tools either grounded or double insulated?

  • Guards in good condition?

  • Right tool for the right job?

  • Powder-actuated tools in use.

  • Powder-actuated tools and loads properly used and/or stored?

  • Powder-actuated tool operators trained on make and model of tool in use?

  • The company's tool and fastener supplier may be able to provide this training.

  • Powder-accuated tool operators wear head, eye, and hearing protection?

  • Is signage "Powder-Actuated tool in use" posted?

  • Powder-actuated tool operators familiar with mis-fire procedure?

  • If a powder-actuated tool misfires, the user must hold the tool in the operating position for at least 30 seconds before trying to fire it again. If it still will not fire, the user must hold the tool in the operating position for another 30 seconds and then carefully remove the load in accordance with the manufacturer’s instructions. This procedure will make the faulty cartridge less likely to explode. The bad cartridge should then be put in water immediately after removal.

    Lack of familiarity with this procedure may indicate a need for tool operator retraining.

  • Laser warning signs posted?

  • Other tool observations or comments?

  • Non LEI tool observations or comments?

Excavation

  • Workers near excavations?

  • Excavations protected by guardrails, fences, or barricades if not readily seen due to plant growth or other visual barriers?

  • Workers in excavations.

  • Utility locates have been conducted prior to start of excavation operations?

  • Competent person familiar with excavation hazards, pertinent OSHA regulations, and soil analysis?

  • Excavation inspected daily by a competent person before workers enter?

  • Soil type determined by competent person?

  • Spoil at least 2 feet from edge?

  • Access/Egress available in trenches 4 feet deep or more?

  • Ladders provided every 25' in trenches 4' deep or more?

  • Excavation over 5 feet deep or otherwise in need of safeguarding per competent person?

  • Excavation safeguarding is in place?

  • Excavations more than 5 feet deep that workers enter require safeguarding to protect workers from excavation collapse hazards. Excavations less than 5 feet deep also require safeguarding if determined necessary by the competent person. Recognized methods of excavation safeguarding include:

    -sloping (slope angle depends on current soil conditions)
    -benching (bench configurations depend on current soil conditions)
    -shielding (often referred to as “trench boxes”)
    -shoring (typically pneumatic or hydraulic systems)
    -design by a registered professional engineer

    Additional information on excavation safeguarding can be obtained by calling Pinnacol’s Safety on Call line at 303-361-4700 or by visiting OSHA’s website at www.osha.gov.

  • Sloping

  • Sloping appropriate for soil type. <br>- 3/4:1 for class A (53 degrees or less)<br>- 1:1 for class B (45 degrees or less) <br>- 1 1/2:1 for class C (34 degrees or less)

  • Benching (A or B soils only)

  • Benching configuration is appropriate for soil type. <br>- 3/4:1 for class A (53 degrees or less)<br>- 1:1 for class B (45 degrees or less) <br>- Width of the first bench is twice the bench height<br>- Maximum bench height is 4"

  • Shielding (trench box)

  • Shield is level with or above excavation edge?

  • Shield protects from all exposed vertical walls?

  • Shield fits tight in excavation to minimize movement during collapse?

  • Excavation extends no more than 2 feet below bottom of shield?

  • Shoring

  • Tabulated data for proper use of shoring system on site for review?

  • Shoring system installed per manufacturer specs for soil type and depth. (sheeting, spanning, depth, etc.)?

  • Combination shielding and sloping?

  • Sloping appropriate for soil type. <br>- 3/4:1 for class A (53 degrees or less)<br>- 1:1 for class B (45 degrees or less) <br>- 1 1/2:1 for class C (34 degrees or less)

  • Shield extends at least 18" above bottom of slope.?

  • Shield protects from all exposed vertical walls.

  • Shield fits tight in excavation to minimize movement during collapse?

  • Excavation extends no more than 2 feet below bottom of shield?

  • Custom-engineered design

  • Engineered by licensed P.E.?

  • Plans on site for review?

  • Other excavation observations or comments.

Cranes and Rigging

  • Crane set up on site.

  • Pre-shift crane inspection completed by competent person?

  • Monthly crane inspection conducted, documented, and on file?

  • Annual crane inspection conducted, documented, and on file?

  • Ground conditions appear adequate?

  • Swing radius of counter weight barricaded off to avoid striking workers and equipment?

  • Outriggers pads are solid, sturdy, and appear at least 3 times the area of the outrigger plates?

  • Outriggers are fully extended?

  • Crane is designed for partial outrigger extension and outriggers are extended to the minimum reduced extension?

  • Crane is designed for "on rubber" lifting with reduced load chart?

  • Crane operated per proper load chart (full extension, partial extension, on rubber, etc.)?

  • Maximum crane radius at least 20 feet from overhead power lines?

  • Power lines have been de-energized, locked-out, and visibly grounded by utility owner?

  • The crane’s work zone has been defined, is at least 20 feet back from the power line, and has been demarcated with an elevated high-visibility marking (warning line, barricades, signs, etc.)?

  • Operator has been instructed against operating crane past established work zone boundaries?

  • Complete requirements for cranes operating near overhead power lines are specified in OSHA Construction safety standard 1926.1408 which can be viewed at www.osha.gov. Operators, riggers, and signal persons should be familiar with this standard.

  • Any other risk concerns involving crane or setup or operation?

  • Company performing rigging operations.

  • Riggers are trained in safe rigging principles.

  • Riggers have reasonable idea of load weights (shipping docs, mfg specs, raw material calculations, etc.)

  • Signal person has been trained and evaluated by the employer or qualified 3rd party and understands how to give and read signals, has a basic understanding of equipment limitations, understands relevant OSHA crane standard requirements, and has demonstrated qualification via oral, written, or practical testing.

  • Documentation of signal person qualification on site.

  • Rigging equipment is in serviceable condition (capacities labeled, free of damage, kinks, stains, etc.)

  • Observed rigging practices appear effective and safe. <br>- tag lines used where appropriate<br>- no workers under suspended loads<br>- loads appear stable<br>- rigging equipment appears to be used per intended use and within its capacity

  • Other rigging observations or comments?

  • Non LEI Rigging observations or comments?

Aerial Lifts

  • Aerial lifts in use.

  • Aerial lift operators trained and authorized?

  • Aerial lift controls clearly marked.?

  • Fall protection used in aerial lift?

  • Type of fall protection used in aerial lift:

  • To ensure proper function of the SRL in the event of a fall, SRL should be rated by the SRL manufacturer for use in an inverted position as the anchor point in the aerial lift is below the worker's D-ring.

  • Total fall distance of the lanyard may result in worker hitting the ground before the fall is fully arrested. LEI should consider using lanyards adjusted short enough to restrain workers from being ejected over the lift's guardrail or use self-retracting lanyards (SRLs) rated by the manufacturer for inverted use due to the anchor points in the lift being located below the workers' D-ring.

  • Other aerial lift observations or comments?

  • Non LEI aerial lift observations or comments?

Heavy Equipment

  • Heavy equipment on site.

  • Equipment with obstructed view to the back are equipped with backup alarms.

  • Equipment appears to be free of significant damage, leaks, and other safety concerns.

  • Parked equipment has brakes set and all buckets, blades, and other implements grounded.

  • Operators have been trained, evaluated, and authorized by employer to operate equipment.

  • Training documented and on file.

  • Employer claims training has been provided but has no records for verification.

  • Machine-specific evaluation and authorization documented and on file.

  • Employer claims evaluation has been conducted but has no records for verification.

  • Operators wear seat belts while operating.

  • Operators maintain 3 points of contact while dismounting equipment.

  • Are flagmen or spotters being used?

  • Other heavy equipment observations or comments.

  • Non LEI heavy equipment observations or comments?

Welding/Cutting

  • Gas Cylinders stored upright and secured?

  • Welding/cutting gloves goggles, face shield, or helmet are worn?

  • Welding activities are shielded?

  • Fire Extinguishers are nearby?

  • Hoses are in good condition?

  • Non LEI welding observations or comments?

Sign-off

  • Project Manager

  • Add signature

  • Supervisor

  • Add signature

  • Evaluator's signature

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.