Trains
-
Check the blankets are without ink and complete
-
Bearings are not damaged
-
check all 60 Encoders cable that are not Banded or damaged, the spring is ok LED is green and no bearings are damaged
-
Check all the Hall Effect sensors for no damage specially on cables
-
Check all the Axiopea boxes are not damaged
-
Perform Currant test from Tzabar tool
Bus bar
-
Check that the Bus Bar is Clean
-
No damaged plastics the bar located inside the plastic
-
Check Bus bar for no Scratches
-
Electrical connection is correct
Communication cables
-
No damaged cables found
-
All the cables are well attached and connected
-
Tie raps are not too tight
-
Cable routing, Molex connector
Axiopea All Boxes
-
Check all the cables are connected and not free, Molex are not damaged, D type connector is locked
-
Driver - No movement found and locked
-
Coil brushes - All brushes are complete and touching the bus bar `
-
Check the screws that holds the Axiopea board, all the screws are locked
Oil system
-
Check for no oil leakage
-
Check that all the tubes are connecting properly
-
check that the tank is without damage
ACS controller
-
Check that all Pi board connection are secured
-
Check all the Molex and cables are not damaged
-
Check that the fan is working
-
Check the Flex cables secured and not damaged