Title Page
-
Site conducted
-
Conducted on
-
Prepared by
-
Location
Fire Door Inspection
Fire Door Inspection
-
Door ID / Number: -
-
Take photos of Door
-
Intended Fire Rating:-
-
Certification labels / plugs present?
-
Take photos of the Cert or Plug if present
-
Test evidence available?
-
Take photos of the Test Evidence if available
-
Overall condition acceptable?
-
Take photos of the door condition
-
Edge condition acceptable?
-
Take photos of the edge condition
-
Bow / twist within acceptable limits
-
Take photos of any unacceptable limits
-
Leaf thickness?
-
Take photos of the door leaf measurements
-
Material
-
Take photos of the door material
-
Condition acceptable?
-
Take photos of the door condition
-
Dimensions within limits?
-
Take photos of the dimensions
-
Overall condition of Seals?
-
Take photos of the condition of the seals
-
Are the seals continuous?
-
Take photos of the seals showing whether the seals are continuous or not
-
Size fitted?
-
Take photos of the size of the seals fitted
-
If smoke seals fitted, is the condition acceptable?
-
Take photos of the condition of the seals
-
If smoke seals fitted are they continuous?
-
Take photos of the seals showing whether the seals are continuous or not
-
Hinge condition ok?
-
Take photos of the hinges and their condition
-
Has appropriate signage been used?
-
Take photos of the signage
-
Have signs been fitted to cover voids?
-
Take photos if signs have covered any voids
-
Sign condition ok?
-
Take photos of the sign condition
-
Intumescent liners fitted?
-
Take photos of the intumescent liners
-
Beads appropriate and securely fixed?
-
Take photos of the beading
-
Door gaps correct (<4mm unless otherwise stated by manufacturer)?
-
Gaps (Top) mm:-
-
Take photos of the top side gap
-
Gaps (Hinge side) mm:-
-
Take photos of the hinge side gap
-
Gaps (Lock side) mm:-
-
Take photos of the lock side gap
-
Gaps (Meeting Edge) mm:-
-
Take photos of the meeting edge gap
-
Threshold gap within manufacturer's limits?
-
Gaps (Threshold) mm:-
-
Take photos of the threshold gap
-
Is the frame securely fixed and correctly installed?
-
Take photos of how the frame has been secured
-
For FD60+ check for intumescent behind the top hinge (unless evidence not required)?
-
Take photos of the intumescent behind top hinge
-
Is intumescent required around the locks Y/N
-
Has this been Fitted Y/N/NA
-
Take photos of the lock intumescent
-
Does the closer operate properly, and ensure that the doorset closes from any position (partially / full open)
-
Take photos of the evidence showing that the door closes fully from any position
-
If a hold open device is fitted, does it operate correctly?
-
Take photos of any hold open devices
-
Check that door frames have been fire stopped to the partition on a sample of the doorsets?
-
Take photos of whether the door frames have been fire stopped
-
Is an intrusive survey recommended
-
Take photos proving whether or not an intrusive survey is needed
-
Is there anything on the doorset that is (or is likely to be) outside of the manufacturer's specification?
-
Take photos of anything outside of the manufacturer's specification
-
Check for fire resistant letter plates and eye viewers
-
Take photos of any fire resistant letter plates and/or eye viewers
-
Single or double leaf:-
-
Single or double action:-
-
Structural Opening (mm)
-
Leaf Size (H x L x W) mm:-
-
Frame Size Exterior (L x W x D) mm:-
-
Frame Size Interior (L x W x D) mm:-
-
Support Construction:-
- Plasterboard
- Brick
- Concrete Block
- Other - See Additional Comments Section
-
Take photos of the support construction
-
Frame to wall sealing: -
-
Frame to wall sealing comments
-
Take photos of the wall sealing
-
Is all Ironmongery in good working condition
-
Ironmongery comments
-
Take photos of Ironmongory
-
Have these items been installed as per manufacturers installation instructions or BS8214: 2016
-
Are any actions required for compliance on this Fire Door?
-
Recomended actions required to make Fire Door compliant
- New Hinges Required
- Adjust Leaf to Frame Gaps between 2mm - 4mm
- New Intumescent Seals / Smoke Seals Required
- Adjust Overhead Closer / Concealed Closer
- New Door Lock / Handle Required
- New Fire Door Required
- New Frame Required
- New Glass for Vision Panel, Side Panel or Overhead Panel
- New Drop Down Seal Required
- Adjust Drop Down Seal
- Seal Frame to Wall
- Other - Please see additional comments section
- Lipping needs replaced
-
Risk Level of Fire Door Set-Documentation Grading
- High-No test evidence, no certification marks
- Medium-Certification marks – installation only
- Medium-Certification marks – manufacture only
- Medium-Test evidence available, which appears to match the specification of the product
- Medium-Certified product, plus certified installation, plus certified inspection or maintenance, records not up to date
- Low-Certified product, plus certified installation, plus certified inspection or maintenance, records up to date
-
Risk Level of Fire Door Set-Condition Grading
- High-Faults or damage to the doorset (including through installation) or components which are likely to reduce the fire resistance
- High-Modifications made to the door
- Medium-No damage, all intumescent present, door gaps correct, firestopping behind architrave not inspected
- Medium-No damage, all intumescent present, door gaps correct, firestopping behind architrave – 10% Sample Checks OK
- Low-No damage, all intumescent present, door gaps correct, firestopping behind architrave inspected
-
Take photos of door documentation and condition
-
Additional comments