Title Page
-
Document No.
-
Audit Title
-
Client / Site
-
Conducted on
-
Location
-
Personnel
-
Technician's Name
-
Prepared for
Owners information
-
Is the building occupied
-
Has the occupancy/hazard changed sine the last inspection?
-
Are all the systems in service?
-
Has there been any modifications to the system since the last inspection?
-
Was there an actuation of device or alarm since the last inspection?
Inspectors section
Sprinkler
-
Are all sprinklers in good condition?
-
Are all sprinklers free of obstruction?
-
Are all sprinklers and wrenches available?
-
In spray coating area, are all sprinklers free of accumulation?
-
Is the hydraulic nameplate in place and firmly attached?
-
Are alarm devices provided and in good condition?
-
Any sprinklers requiring testing have been tested?
-
Any sprinklers requiring replacement have been replaced?
Piping
-
Is all sprinkler piping in good condition?
Hangers/seismic bracing
-
Are all hangers and seismic bracing in good condition, firmly attached, and free of corrosion?
Fire department connections
-
Are the fire department connections visible and in good condition?
-
Are caps and plugs in place?
Water Supply
-
What is the water supply pressure? (Psi)
Wet Systems
-
In area protected by wet system, it the building properly heated?
Dry Systems
-
Is there a dry system?
-
Is the system heated properly?
-
Are the low points drained?
-
Is there adequate air pressure to the system?
-
Is there adequate water pressure to the system?
-
Dry Pipe Valve Test Results
Dry Pipe Valve
-
Dry Valve System Number:
-
System Operational?
-
Inspector:
-
Comments:
Guages
-
Are guages in good condition and indicating proper water, air, or gas pressure?
Main Drain Test
-
Has the main drain been tested?
-
Were the results recorded?
-
Were there changes from the last test?
Water Flow Devices
-
Were all water flow devices tested?
Antifreeze
-
Is there an antifreeze system?
-
Has the antifreeze solution been tested by measuring specific gravity?
-
Were the results recorded?
Stand Pipe and Hose System
Stand Pipe and Hose Systems List
-
Is there Stand Pipe or Hose Systems?
-
Stand Pipe and Hose
Stand Pipe and Hose System
-
Class of Service
-
Hose Type
-
Type of System
-
Nozzle Type
-
Water Supply
-
Are stand pipe and hose in normal position (open or shut)?
-
Are stand pipe and hose in good condition and free of damage?
-
Are the valves...
-
Are hose valve oulet's caps and gaskets in place?
-
Are hose connections free of damage?
-
Are valve handles in place?
-
Are hose valve outlets free of obstructions?
-
Are restricting devices in place?
Hose
-
Are hoses removed inspected and re-racked?
-
Are hoses free of mildew, damage, and deterioration?
-
Are hoses compatible threads on couplings?
-
Are hoses connected?
-
Are hoses test date current?
Hose Nozzles
-
Are hose nozzles and gaskets in place?
-
Do the hose nozzles operate smoothly?
-
Are hose nozzles free of obstructions?
Hose Storage Device
-
Are hose storage devices free of damage and obstructions?
-
Are hoses properly racked, rolled, clips in place, and correctly contained?
-
Are hose storage devices easy to operate?
Hose Cabinets
-
Are hose cabinets able to swing open 108 degrees?
-
Are hose cabinets glazings in good condition?
-
Are hose cabinets locks, if present, functioning properly?
-
Are hose cabinets glass break devices properly attached?
-
Are hose cabinets properly identified?
-
Are hose cabinets free of obstructions?
-
Are hose cabinets equipment/devices accessible?
Water Storage Tanks
-
Is there a Water Storage Tank?
-
Have all tank vents (screened or open) been closed?
-
Have the lightning protection systems been maintained in accordance with manufacturers' specifications?
-
Has the cathodic protection system been inspected and serviced?
-
Have all tank thermometers been maintained in accordance with manufacturer's specifications?
-
Are valve pits and valve or heater houses maintained at minimum of 40 deg F?
-
Is the tank water temperature at least 40 deg F?
-
Is the tank heating system operating properly?
-
Is the tank full of water?
-
Is the water in good condition?" (not frozen, and free of debris and algae)
-
Is there proper air pressure (for pressure tanks)?
-
Are the exterior of the tank, supporting structure and catwalks or ladders in good structural condition?
-
Is the area around the tank and supporting structure free of: combustible materials, materials that could accelerate corrosion or rot, ice buildup, or erosion?
-
Are all hoops and grillage (on wooden tanks) in good condition?
-
Is the exterior painted, coated, or are insulated surfaces of the tank and supporting structure in good condition?
-
Are all expansion joints in good condition (no leaks or cracks)?
-
Is the tank interior in good condition?
-
Are the interior of the pressure tanks in good condition?
-
Does the low water temperature alarm work?
-
Does the high water temperature limit switch on the heating tank work?
-
Does the low water level alarm work?
-
Does the high water level alarm work?
-
Has sediment been drained or flushed from the tank?
-
Is the water level indicator accurately indicating the water level?
-
Have the pressure gauges been tested with a calibrated guage in accordance with manufacturers specifications?
-
Have all tank drain valves been fully cycled?
Deluge Valve
-
Is there a Deluge Valve?
-
Is the valve in good condition?
-
Is all the trim connected properly?
-
Is the heating system in good condition?
Automatic Detection Equipment
-
Are the detectors securely attached to their supports?
-
Are they protected from corrosion where necessary?
-
Are they protected from weather where necessary?
-
Is all equipment undamaged?
-
Is all the wiring or tubing intact?
Water Spray System Piping, Fittings, Hangers, Nozzles
-
Is there a water spray system?
Valves controlling water spray system
Insulation
-
Is the insulation intact on the structures, vessels, or equipment?
Nozzle Condition
-
Are the nozzles in good condition?
-
Are the plugs or caps in place where needed?
-
Are the nozzles properly aimed to protect object or hazard?
-
Has the object or hazard changed size to require fewer or more nozzles?
Water Spray Valves
Drainage
-
Have there been changes in the water spray that render drainage inadequate?
-
Are nearby processes or buildings prevented from flooding upon opening drains?
-
Are drains obstructed?
-
Valve Information
Valve
-
Valve Number / Tag
-
Location
-
Open
-
Shut
-
Sealed
-
Static Pressure (Psi):
-
Residual Pressure (Psi):
-
Were valves operating properly?
-
Are all valves open?
-
How are they supervised?
-
Are identification signs on the system?
-
Were Main drain tests completed where necessary?
System Operating Tests
-
Management Notified?
-
Fire Brigade Notified?
-
Fire Department Notified?
-
Alarm monitoring station notified?
-
All departments or Processes affected by or interlocked with this spray system notified?
-
Have steps been taken to prevent damage to or flooding of nearby buildings or processes?
-
Has the underground leading to the water spray system riser been flushed to remove debris?
-
List department name and contact information:
-
Has the regular monthly inspection been completed in conjunction with this test?
Piping
-
Is the piping in good condition?
-
Is the piping properly connected?
-
Is the piping properly aligned?
-
Were all low points drained during this inspection?
Fitting Condition
-
Are the rubber gasket fittings properly located?
-
Are the fittings in good condition?
Hanger Condition
-
Are the hangers securely attached to supports?
-
Are the hangers securely attached to piping?
-
Are the hangers in good condition?
Operational Test Information
-
Valve Tested
Valve
-
Automatic release Make:
-
Type:
-
Number of detectors:
-
Number of circuits:
-
Manual release location:
-
Manual release Tested?
-
Systems actutates or shuts down the following equipment (list all):
-
Automatic Test Method:
-
Alarms:
-
Nozzle pattern:
-
Pressure at hydraulic nozzle (Psi):
-
Pressure at deluge valve (Psi):
-
Test results ( if slow compared to previous explain):
-
Valve Name / Tag
-
Make:
-
Model:
-
Size:
-
Pressure (Psi):
Return to Service
-
Were all strainers cleaned of debris?
-
Were all strainers in good condition?
-
Were the manufacturer's instructions followed when returning this to service?
-
Is the system in full service?
Foam Water System
-
Is there a foam/water system?
-
What are the concentration test results from the flow tests?
-
Were the foam concentrate samples taken?
-
Is the foam tank level full?
-
Are the foam tank valves in proper position?
-
Is the pressure vacuum vent operational?
-
Is the foam pump free to rotate?
-
Is power available to foam pump?
-
Are foam pump controls and selector switches in proper position?
-
What is the foam pump capacity (list gpm and psi)
-
What type of proportioning system is present?
-
Is there any piping damage?
-
Are all supports present and undamaged?
-
Are discharge devices in good condition?
-
Are discharge devices aimed properly?
-
Are discharge devices free of obstruction?
Valves
Check Valves
-
Was the five year interval inspection performed?
-
5 year inspection date:
Alarm Valves
-
Alarm tested satisfactorily
Flow Test Results
-
Flow (gpm):
-
Static Pressure (Psi):
-
Residual Pressure (Psi):
-
If Not Conducted explain:
Dry Pipe Valves
Flow Test Results
-
Flow (gpm):
-
Static Pressure (Psi):
-
Residual Pressure (Psi):
-
If Not Conducted explain:
-
Was the five year maintenance performed?
-
Date of last five year inspection?
-
Was the annual trip test conducted?
-
Was the only full flow test conducted?
-
Was the internal inspection satisfactory?
-
Was the test conducted with QOD?
-
What is the starting air pressure (Psi):
-
What is the time for the water flow (seconds)?
-
Was the QOD test satisfactory?
-
Was the DPV test satisfactory?
-
Was the low air pressure alarm test satisfactory?
-
Was the air maintenance device test satisfactory?
-
Were the low points drained?
-
Desired Air Pressure:
-
Maintained Air Pressure:
-
Are the valve enclosures maintained above 40 deg F?
Deluge / Pre-action Valves
-
Are the valve enclosures maintained above 40 deg F?
-
Are the supervisory air pressures properly maintained?
-
Are the supervisory air pressures properly maintained?
-
Are the valve enclosures maintained above 40 deg F?
-
Was the five year maintenance performed?
-
Date of five year maintenance:
-
Are the fire detection devices free of damage or corrosion?
-
Were the systems tripped in accordance with manufacturer's instructions?
-
Were the results satisfactory?
Flow Test Results
-
Flow (gpm):
-
Static Pressure (Psi):
-
Residual Pressure (Psi):
-
If Not Conducted explain:
Sprinkler Pressure Regulating Control Valves
-
Is downstream pressure in accordance with design?
OUTLET Flow Test Results
-
Flow (gpm):
-
Static Pressure (Psi):
-
Residual Pressure (Psi):
-
If Not Conducted explain:
INLET Flow Test Results
-
Flow (gpm):
-
Static Pressure (Psi):
-
Residual Pressure (Psi):
-
If Not Conducted explain:
Fire Department / Hose Rack Pres. Reg. Valves
-
Was the five year flow test conducted in accordance with manufacturer's specifications?
-
Date Conducted:
Fire Pump Pressure Relief Valves?
-
Are there Fire Pump Pressure Relief Valves?
-
Are the valves protected from physical damage?
-
Are the valves in proper open or closed position?
-
Are the valves properly sealed, locked, or supervised?
-
Are the valves accessible?
-
Are the valves operable?
-
Was the annual lubrication performed?
-
Is the circulating valve operating properly?
Back Flow Preventers
-
Are the back flow preventers inspected/maintained in accordance with manufacturer's instructions?
Fire Department Connections
-
Are the fire department connections visible, accessible, and in good condition?
-
Are plugs and caps in place?
-
Are automatic drain valves operating properly?
Fire Pumps
-
Fire Pump Data
Fire Pump
-
Pump Name / Identification Number
-
Date Pump was last tested:
-
Shut off pressure (Psi):
-
Pump Rating (gpm & psi):
-
Pump peak load:
-
Automatic Start
-
Automatic start pressure (Psi):
-
Tested?
-
Remote Start
-
Remote start pressure (Psi):
-
Tested?
-
Automatic Stop
-
Automatic stop pressure (Psi):
-
Tested?
-
Were the relief valves functioning properly?
-
Were the packing glands adjusted?
-
Were the motor and pump bearings lubricated?
-
Was the engine oil/coolant checked?
-
Was the battery / cables checked?
-
Were the controller lights functioning?
-
Was the controller alarm functioning?