Title Page
-
Conducted on
-
Prepared by
-
Location
-
Location
-
Model number / Serial number
-
Manufacturer
Accessibility of Documents
-
Installation / Operation / Parts Manual (ALIOM 5.6.2.1)
-
ALI "Lift It Right" Guide (ALIOM 5.6.2.2)
-
Safety Requirements for Operation, Inspection, and Maintenance Guide (ANSI/ALI ALIOM)
-
Rated Load Capacity Label (ALIOM 5.6.2.5)
-
Check for Lift Safety Labels ALI/WL101 (ALIOM 5.6.2.4)
-
Clearance around lift (ALIOM 5.6.2.7)
Lift and Bay Inspection
-
Concrete condition (Installation /Operation Manual)
-
Examine all accessible structural components for signs of fatigue, overloading, misuse, or abuse including welds. (ALIOM 5.6.2.8)
-
Are all nuts and bolts present and secure (ALIOM 5.6.2.14)
-
What type of lift is being inspected?
-
Report presence of water in cassette tubes covering bottom frame supports (ALIOM 5.6.2.27)
-
While raising and lowering the lift ensure the lift is synchronized (ALIOM 5.6.2.20)
-
Check with operator to ascertain any unusual operating characteristics (ALIOM 5.6.3.4)
Arms
-
Check arm pin holes for excessive wear (ALIOM 5.6.2.14)
-
Is stop bolt present on arms (ALIOM 5.6.2.12)
Rubber Pads
-
Present? (ALIOM 5.6.2.17)
-
Damaged? (ALIOM 5.6.2.17)
Lock Mechanism
-
Operate the lift and check the operation of the positive stop & the lift locks (ALIOM 5.6.2.16)
-
Do locks operate smoothly? (ALIOM 5.6.2.16)
Hydraulic Hoses & Cylinders
-
Are fittings tight? (ALIOM 5.6.3.1)
-
Are there any leaks? (ALIOM 5.6.3.1)
Power Unit
-
Check electrical motor switch cover for damage or exposed wires (ALIOM 5.6.3.9)
-
Check lift controls to ensure accessibility, unobstructed view and automatic return to neutral, or off when released (ALIOM 5.6.2.10)
-
Are the electrical components labeled appropriately? (ALIOM 5.6.2.9)
-
Lift inspected by
-
Store manager
Lift Platform, Legs, and Lock Bar
-
Check hinge barrels & pins for wear & that they pivot freely (ALIOM 5.6.2.19)
-
Insure all pivot points are lubricated (ALIOM 5.6.2.19)
-
Check for corrosion (ALIOM 5.6.2.23)
-
Does lock operate smoothly (ALIOM 5.6.2.16)
-
Check for damage (ALIOM 5.6.2.23)
-
Are rubber pads present?
-
Are spotting block present?
-
Does lock release return to neutral when fully lowered (ALIOM 5.6.2.16)
-
Are anchor bolts torqued to 80 ft/lbs
Hydraulic Hoses & Cylinders
-
How many cylinders does the lift have?
-
Are all fittings tight? (ALIOM 5.6.3.1)
-
Are there any leaks? (ALIOM 5.6.3.1)
Power Unit
-
Check electrical motor switch cover for damage or exposed wires (ALIOM 5.6.2.9)
-
Check lift controls to ensure accessibility, unobstructed view and automatic return to neutral, or off when released (ALIOM 5.6.2.10)
-
Are the electrical components labeled appropriately? (ALIOM 5.6.2.9)
-
Lift inspected by
-
Store manager
Chain or Cables
-
Check for corrosion (ALIS 6.1.1)
-
Check for wear (ALIS 6.1.1)
-
Check for damage (ALIS 6.1.1)
-
Check for tension & adjust as needed (ALIOM 5.6.2.20)
Chain Rollers or Sheaves
-
Check to see if loose (ALIOM 5.6.2.24)
-
Are rollers/sheaves turning freely (ALIOM 5.6.2.24)
-
Check contact surface wear (ALIOM 5.6.2.24)
Runways
-
Ensure proper operation of automatic runway stops (ALIOM 5.6.2.11)
-
Check for presence of fixed runway stops if applicable (ALIOM 5.6.2.11)
-
Ensure runways are secure (ALIOM 5.6.2.11)
-
Check the security of turntables (ALIOM 5.6.2.11)
-
Check the security of slip plates (ALIOM 5.6.2.11)
Overhead Cylinder Beam
-
Check for bowed overhead or lose bolts (ALIOM 5.6.2.14)
Hydraulic Hoses & Cylinder
-
Check for leaks (ALIOM 5.6.3.1)
Lock Mechanism
-
Do locks operate smoothly (ALIOM 5.6.2.16)
-
Check function of lock release device (ALIOM 5.6.2.16)
Power Unit
-
Check electrical motor switch cover for damage or exposed wires (ALIOM 5.6.2.9)
-
Check lift controls to ensure accessibility, unobstructed view and automatic return to neutral, of off when released (ALIOM 5.6.2.10)
Columns
-
Torque all anchor bolts to 80 ft/lbs (ALIOM 5.6.2.14)
-
Check columns for plumb (ALIOM 5.6.2.14)
-
Ensure all hardware is tight (ALIOM 5.6.2.14)
-
Ensure safety rod is clean dry and smooth (ALIOM 5.6.4.1)
-
Ensure columns are free of dirt and debris (5.6.2.19)
-
Lift Inspected by
-
Store manager
Cables or Chains
-
Check for corrosion (ALIS 6.1.1)
-
Check for wear (ALIS 6.1.1)
-
Check for damage (ALIS 6.1.1)
Sheaves & Axles
-
Check for cracks (ALIOM 5.6.2.24)
-
Check to see if loose (ALIOM 5.6.2.24)
-
Check bushings (ALIOM 5.6.2.24)
-
Are sheaves turning freely (ALIOM 5.6.2.24)
Arms & Rubber Pads
-
Check arm pins in carriage for excessive wear (ALIOM 5.6.2.14)
-
Is stop bolt present on arm (ALIOM 5.6.2.12)
-
Are rubber pads present (ALIOM 5.6.2.17)
-
Are rubber pads damaged (ALIOM 5.6.2.17)
Arm Restraints
-
Check for debris and damage to threaded rod or gears (ALIOM 5.6.2.13)
-
Do arm restraints operate smoothly (ALIOM 5.6.2.13)
Lock Mechanism
-
Check for damage to latch cable (ALIOM 5.5.2.13)
-
Check cable adjustment (ALIOM 5.6.2.16)
-
Do locks operate smoothly (ALIOM 5.6.2.16)
-
Are lock safety covers present (ALIOM 5.6.2.16)
Overhead
-
Check for bowed overhead or loose bolts (ALIOM 5.6.2.14)
-
Are cables or hoses tangled or rubbing (ALIOM 5.6.2.14)
-
Verify safety shutoff is working properly and no loose, exposed or un safe wires (ALIOM 5.6.3.1)
Hydraulic Hoses & Cylinders
-
Check for tight fittings (ALIOM 5.6.3.1)
-
Check for leaks (ALIOM 5.6.3.9)
Power Unit
-
Check electrical motor switch cover for damage or exposed wires (ALIOM 5.6.2.9)
-
Check lift controls to ensure accessibility, unobstructed view and automatic return to neutral, or off when released (ALIOM 5.6.2.10)
-
Confirm appropriate elect component labeling (ALIOM 5.6.2.9)
Columns
-
Check anchor bolt torque to 80 ft/lbs (ALIOM 5.6.2.14)
-
Check columns for plumb
-
Check to make shure all hardware is tight (ALIOM 5.6.2.14)
-
Lift inspected by
-
Store manager