Title Page
-
Site conducted
-
Conducted on
-
Prepared by
Equipment Information
-
Equipment Type
-
Equipment Manufacturer
-
Make / Model of Equipment
-
SN#
-
Build Date
-
Data Plate
-
Voltage
-
Amperage
-
Phase
-
Hz
-
Operating Air Pressure
-
Hydraulic Oil Reservoir - in Gallons
-
Is equipment UL Approved / Listed
Commissioning Team
-
MPC Safety Rep
-
MPC Engineering Rep
-
MPC Quality Rep
-
Equipment Manufacturer Rep
-
Customer Rep (If Applicable)
Additional Team Members
-
Rep Title
-
Rep Name
-
Rep Company
Machine Design/Controls
-
EHS Plan Review was completed
-
FM Global Plan Review was completed
-
Municipality Approval and Permiting Received
-
As-built drawing submitted
-
Instrument calibration certificate submitted
-
All control panels and buttons clearly marked to identify function
-
All controls tested
-
All jog / run / stop / reset buttons all tested
-
All rotating parts are permanently marked with rotation arrows
-
Equipment can be visually inspected without being disassembled in all areas where product could make contact.
-
Equipment design provides quick and easy access for service and maintenance.
-
Do walkways, stairways, and ladders provide safe access to all levels.
-
Are guardrails provided on all platforms and walkways at 4' or above.
-
Have any confined spaces been identified?
-
Have confined spaces been guarded to prevent access
-
Have confined spaces been labeled with clear signage?
-
Have Egress Routes been changed due to equipment install?
-
Have employees been trained on new routes?
-
Are Egress Routes fully accessible and visible?
-
Is exit signage easily visual from work area?
-
Equipment is properly anchored?
-
All fencing, guards, rails, etc. 6' or above is anchored to the floor.
-
Equipment/Peripheral Equipment does not pose a tipping hazard
-
Overhead hazards are eliminated. (Head room @ least 7' with no obstructions below 6'8")
-
Equipment is designed to allow easy and thorough cleaning.
-
Cleaning SOP has been created.
-
All peripheral equipment, such as motors, sensors, etc. are properly mounted.
-
E-Stops are located at every workstation?
-
All conveyors 6' or longer have a life-line installed?
-
Skirting around the machine leaves a gap of no more than 18"
-
Maintenance receptacles are GFCI and receptacles external of control enclosure are covered when not in use.
-
All access panels or doors that provide access to robotic or machine cells are interlocked and outfitted with a capture key lockset.
-
There is a minimum of 18" clearance between robot movement and any fixed structure including building, fences, columns, utilities, etc.
-
Pendant controls that reach inside equipment, work cell, or robotic cell, are outfitted with an E-Stop.
Safeguarding
-
All points of operation are properly protected.
-
Guards are designed of ridged material and require a tool to remove.
-
Guards that are not permanently affixed are interlocked.
-
Guards are designed not to deflect with personal contact.
-
Guards have no sharp edges or introduce no hazard.
-
Large guards are constructed in sections to facilitate the safe removal/reinstallation for maintenance/service
-
All rotating/moving parts are protected or guarded.
-
All pinch points are guarded.
-
All crush and shear points are guarded.
-
All electrical components are covered and secured.
-
All nip points are guarded.
-
All entanglement hazards are guarded.
-
All rotary shafts within reach are shrouded or guarded.
-
Rotating shaft ends protruding more than a 1/4" are covered, capped, or guarded.
-
All chains and sprockets are guarded.
-
All hot components are guarded or protected.
-
All power transmissions are guarded or protected.
-
All fan blades located 7' or less are guarded.
-
All cabinets and access doors/panels are outfitted with interlocks.
-
When lubrication or adjustment is done with the machine running, lubrication or adjustment points must be located outside the hazard area.
-
Alarm/horn and stack light is in place with a minimum 3 sec delay to alert EE's of start-up, fault, error, etc.
-
Light curtains are installed at distances which coordinate with equipment stopping time.
-
Equipment is designed to stop in a safe stable state in the case of power loss.
-
All Safeties tested for functionality and passed
-
Number of E-Stops
E-Stops
-
E-Stop #
-
E-Stop Location
-
Tested
-
Number of Lifelines
Lifelines
-
Lifeline #
-
Lifeline Location
-
Lifeline Tested
-
Number of Interlocks
Interlocks
-
Interlock #
-
Interlock Location
-
Interlock Tested
-
Number of light curtains
Light Curtains
-
Light Curtain #
-
Light Curtain Location
-
Light Curtain Tested
Electrical
-
Greenline Audit Completed
-
All electrical components are labeled as pre specs and match electrical drawings
-
Electrical schematics / single line drawing provided
-
Is panel layout correct and matches line drawing.
-
Redundant safety circuits wired properly and to safety PLC for fail safe.
-
All electrical cabinets are lockable.
-
All safety devices wired on safety circuit for fail safe
-
All safety devices wired for a single point of reset.
-
Power feed supports equipment needs.
-
Electrical facilities support equipment needs (Breakers, panels, disconnects.
-
Wiring, cables, appliances, and connectors are of the appropriate rating based on equipment needs.
-
Power drops for permanent equipment are within approved conduit and supported from floor to ceiling by Unistrut or mounted to building walls/columns.
-
Cord reels are used only for temporary or mobile applications and are outfitted with strain relief on all cords, and a shock resistant double insulated, GFCI receptacle.
-
Equipment bonding and grounding has been verified.
-
Arc Flash Analysis has been completed and cabinets labeled.
-
All motor disconnects are located within close proximity and lockable.
-
There are no open conduit or conduit bodies.
-
There is no evidence of exposed wiring.
-
All OOS equipment is de-energized.
-
Partially demo'd electrical is disconnected at both ends and labeled.
-
All electrical cords and wires are protected from coming into contact with sharp edges such as cabinets, shelves, equipment parts, etc.
-
There are an adequate number of receptacles installed to support equipment and workarea.
-
GFCI's are installed in potentially wet areas.
-
All knockouts and openings in electrical cabinets and other facilities are covered with blanks or appropriate means.
-
All covers, panels, and doors are secure.
-
Equipment is free of exposed wiring.
-
Conduit or receptacles are not mounted to equipment with the exception of manufacturer installed maintenance receptacles.
-
Low voltage wiring is properly secured to prevent snags or tripping hazards.
Emergency Equipment
Eyewash Stations
-
Eyewash stations are located within 10 walking seconds of any eye hazard classified as "high risk"
-
Eyewash stations are accessible and ready for use.
-
Eyewash inspection has been added to maintenance schedule.
Emergency Shower
-
Emergency shower is located within 10 walking seconds of any skin hazard classified as "high risk"
-
Emergency shower is accessible and ready for use.
-
Emergency Shower inspections have been added to maintenance schedule.
-
EM Lighting properly located and illuminates work area and egress
-
Has the egress path been changed due to this equipment add?
-
Have employees been trained on new egress?
-
Have site evac maps been updated?
-
Have site drawings (including life safety drawing) been updated?
-
Have sprinkler changes/upgrades been completed?
-
Fire extinguishers are appropriately located.
-
Appropriate extinguisher types have been selected.
-
Fire extinguisher location map has been updated with the vendor.
-
Fire extinguisher monthly inspections are scheduled.
-
Non-conductive clearing tools are located at areas such as heat tunnels, where product may get jammed and cause fire.
Pneumatic Systems
-
A master lockable air dump is installed and within arm's reach of master electrical disconnect.
-
Dump valve evacuates all pressurized air within the machine.
-
All pneumatic components accessible for maintenance and adjustment (Filter heads, cylinders, solenoids, etc.)
-
All filters, regulators, and lubricators are fitted with a pressure gauge.
-
All air components are rigidly mounted and protected.
-
Air tubing in flexible areas are properly bundled together.
-
Air tubing mounted and protected from "whipping"
-
Air tubing and fittings are properly rated for application.
-
Air filter housing caged or guarded.
-
Air lines are free from leaks (including fittings).
-
Cylinders equipped with cushions or bumpers.
-
Booster tank pressure recovers w/ each cycle.
Piping
-
Piping tracing complete.
-
All piping is labeled, guarded, and insulated.
-
Proper use of piping and flanges.
-
Correct gaskets and bolting used.
-
Piping is properly supported and protected from vibration.
-
Isolation valves, handles, and stored energy labeled.
-
Adequate drains, flush points, and purge connections supplied for maintenance.
-
Process and service connections correct.
-
All valves are lockable.
Lockout Tag Out
-
All energy control points are lockable
-
All energy control points are clearly labeled.
Energy Control Points
-
Energy Type
-
Equipment Specific Procedures created and posted.
-
Have ESP been tested?
-
Have APMs been reviewed, documented, and posted?
-
APM information available to Operators.
-
All Operators, Maintenance, and other affected team members have been trained on LOTO ESP's and APM's.
-
All blocking devices are integrated into the equipment.
-
Special LOTO devices/tools have been included.
Maintenance
-
Equipment is registered in EAM.
-
PM schedule has been entered into EAM.
-
Operator Manual has been provided.
-
Maintenance Manual has been provided.
-
Parts list is called out in Maintenance Manual.
-
High rotation spare parts are on order.
-
Maintenance training has been completed.
-
Any special tools needed are ordered.
-
3rd Party Service Contract is set-up.
-
Programing and recipe backups are on network.
Walking, Working Surfaces
-
A clear, delineated walkway provides access to the equipment.
-
Walkways and aisleways are clearly painted.
-
Walkways are protected/guarded from forklift traffic.
-
Walkways and work areas are free of slip, trip, and fall hazards.
-
Equipment footings, casters, cables, or peripheral equipment does not pose a trip or bump hazard.
-
Work areas are not cluttered or cramped.
-
If maintenance or operators are expected to enter a machine area for regular service, hand holds, and integrated steps are provided.
-
Work areas and walkways are free of suspended bump hazards.
-
Lilly pads or solid crosswalk belting are installed in areas where team members are expected to cross a conveyor.
-
All holes or gaps 2" or more in walking/working surfaces must be covered (secured) or filled.
-
All grating is anchored.
-
All surface railings have 42" top rail and 21" mid-rail with a 4" toe board.
-
Top railings on stairs are between 30-34" with a mid-rail between.
-
Minimum stair width is 22"
-
Portable Safety work stairs are provided in all areas where frequent access to elevated areas is needed (Baler Chutes, Conveyors, etc.)
Ergonomics
-
Have fit for duty tests requirements been updated to reflect new equipment/processes?
-
Need for stooping, bending, stretching, and over reaching has been eliminated or minimized.
-
Need to carry, push, or pull heavy loads has been eliminated or minimized.
-
Hand position for all heavy work is 2-8" below elbows.
-
Standing work stations have work surfaces of between 34-40" deep.
-
Sitting work stations have a surface between 26-30" deep.
-
Forward reaches are limited to 20"
-
Reaches below the knees or above the shoulders are eliminated or minimized.
-
Twisting beyond 45 degrees is eliminated.
-
Antifatigue mats are used in areas where team members must stand for long periods of time.
Environmental
-
All local, state, and federal permits have been received.
-
List all permits needed (Air, Waste, SPCC, SWPPP, Etc.)
-
Asbestos survey completed (Buildings built before 1982)
-
Mapping for permits such as SPCC or Air Permits has been updated.
-
Backflow prevention has been installed and registered with the municipality to prevent contamination of potable water supply.
-
Waste handling plan has been reviewed by EHS and Quality.
-
USDA has been notified of changes (If Applicable)
-
General
-
Appropriate signage installed.
-
Sharp edges on equipment, guides, chutes, etc. has been eliminated.
-
Noise levels have not been read at or above 85 dBs
-
If above 85 dBA, a 8hr time weighted average must be explored and a hearing conservation program must be initiated.
-
Adequate lighting is provided.
-
Offices, laboratories, and show rooms: 500 lux
-
Factories and workshops: 750 lux
-
Warehouse loading bays: 300–400 lux
-
Lobbies, corridors, and stairwells: 200 lux
-
Warehouse aisles: 100–200 lux
-
New chemicals have been reviewed and approved by EHS & Quality
-
New chemical SDSs have been received and uploaded
-
Affected team members have been trained on new chemicals
-
New PPE requirements have been reviewed and approved by EHS
-
New PPE has been sourced and available
-
Affected team members have been trained on PPE.
-
Site lift truck fleet adequate to support new equipment.
-
All lifts, hoists, cranes, and booms have be certified by 3rd party.
-
Hazard warning signage has been installed.
-
All HOT equipment components have been labeled.
-
Operator training, including safety considerations, have been completed.
-
Operating SOPs and Work Instructions have been submitted.
-
Make shift appliances such as extension cords, rope, zip-ties, hoses, tape, banding, etc. have been removed.
-
Proper floor drainage is provided for steam, wet processes, condensers, etc.
-
Spill procedures have been documented.
-
Responsible team members have been trained on spill response procedures and methods.
-
Springs and other "under tension" components have been labeled, and controlled/protected.
-
Enclosures are free from combustibles.
-
All flammable liquids are stored in flammable cabinets.
-
Cabinets that will be opened during service and maintenance are outfitted with props or locking access doors to prevent unintended closure.
-
All fencing and guardrails are properly anchored to the floor.
-
All lasers have been secured and properly shielded.
-
General ventilation of the area is adequate.
-
Equipment specific ventilation is appropriate.
Approvals/Completion
-
-
Task Item
Non-Critical Items (Completed by due date)
-
Task Item
Sign-Offs
-
EHS Rep
-
Engineering Rep
-
Quality Rep
-
Site Rep
-
Customer Rep
-
Vendor Rep
-
Additional Notes: