Information
-
Audit Title
-
Document No.
-
Client / Site
-
Conducted on
-
Prepared by
-
Location
-
Personnel
DATES AND TIME
-
TIME ARRIVED ON SITE
-
TIME LEAVING SITE
BARRIER INFORMATION
-
ENTER BARRIER MODEL:
-
ENTER HPU CONTROL PANEL TYPE:
-
ENTER BARRIER SERIAL NUMBER.
BARRIER
-
INSPECTED BARRIER APPEARANCE?<br>(COMMENT ON CONDITION OF BARRIER, TAKE PICTURE IF POSSIBLE)
-
CLEANED AROUND BARRIER PLATE?
-
CLEANED AROUND BARRIER DRAINS?
-
CHECKED BOTH KNEE BRACE COVERS AND BOLTS?
-
CHECKED "STOP" DECAL ON BARRIER FRONT?
-
CHECKED CONDITION OF "ANTI-SKID" ON BARRIER PLATE?
-
CHECKED CONDITION OF "PAINT COLOR" ON BARRIER PLATE?
-
CHECKED GREASE FITTINGS ON BARRIERS?
-
CHECKED BARRIER PLATE "LEVEL" WHEN IN THE DOWN/OPEN POSITION?
-
ARE BARRIER DRAIN COVERS INSTALL?<br>(IF MISSING ENTER SIZE IN COMMENTS)
-
CHECKED DOWN LIMIT SWITCH AND MOUNT?
-
CHECKED DOWN LIMIT SWITCH WIRES AND CONNECTIONS?
-
CHECKED CONTROL PANEL WIRING TO BE NEAT AND SEATED?
-
CHECKED BARRIER TO SEE IF IT MAKING ANY NOISE?<br>
HPU
-
CHECKED BARRIER HPU CONDITION?<br>(ENTER COMMENTS/TAKE PICTURE)
-
CHECKED HYDRAULIC CYLINDER?
-
CHECKED HYDRAULIC HOSES AND CONNECTIONS TO CYLINDER?
-
CHECKED HYDRAULIC HOSES AND CONNECTIONS TO ACCUMULATOR?
-
CHECK ACCUMULATOR PRESSURE? (RECORD PRESSURE READING)
-
CHECKED HYDRAULIC HOSES AND CONNECTIONS TO MAIN HOSE LINE?
-
CHECKED HPU POWER?<br>(RECORD POWER)
-
CHECKED HYDRAULIC OIL LEVEL?
-
DOES OIL LOOK CONTAMINATED?
-
DOES OIL NEED TO BE REPLACED?<br>
-
WAS THE OIL REPLACED? (IF SO, COMMENT/REPORT)
-
CHECKED HYDRAULIC OIL FOR LEAKS? (CLEAN ALL VALVES AND TANK OF DIRT AND DEBRI)
SAFETY LOOPS
-
CHECKED FRONT SAFETY LOOP?
-
CHECKED FRONT REAR SAFETYLOOP?
-
VERIFY LOOP DETECTOR SAFETY OR CARD SYSTEM<br>(RESISTANCE 2 Ohm)
-
VERIFY LOOP DETECTOR SAFETY OR CARD SYSTEM<br>(LOOP INDUCTANCE BETWEEN 70-1000 uH)
SLIDE GATES
-
CHECKED OPEN CYCLE?
-
CHECKED CLOSED CYCLE?
-
CHECKED STOP FUNCTION?
-
CHECKED OPEN LIMIT?
-
CHECKED CLOSED LIMIT?
-
CHECKED ALL ROLLER GUIDES?
-
CHECKED ROLLER SKATES?
-
CHECKED THE BELT AND ASSY?
-
CHECKED CONDITION OF GATE?
-
CHECKED CHAIN FOR WEAR AND KINKS?<br>(SEATED AND CONNECTED CORRECTLY)
-
CHECKED THE GATE IS LEVEL?
-
CHECKED ALL HARDWARE FOR DAMAGES OR LOOSE CONNECTIONS?
-
CHECKED TO INSURE CONTROL UNIT IS BOLTED DOWN?
-
GREASED AND LUBED ALL NECESSARY MOVING PARTS?
BARRIER CYCLES
-
CHECKED E-UP CYCLE (.75 TO 2 SECONDS) RECORD ACTUAL READING
-
BARRIER UP CYCLE (3 TO 8 SECONDS) RECORD ACTUAL READING
-
BARRIER DOWN CYCLE (3 TO 8 SECONDS) RECORD ACTUAL READING
-
DOES BARRIER RESET?
-
DOES DOWN SPEED NEED TO BE ADJUSTED? (RECORD ANY CHANGES THAT ARE MADE)
-
CHECKED PRESSURE SWITCH?
MASTER CONTROL PANEL
-
CHECKED/TESTED POWER KEY?
-
CHECKED/TESTED POWER INDICATING LIGHT?
-
CHECKED/TESTED E-UP BUTTON?
-
CHECKED/TESTED E-UP LIGHT?
-
CHECKED/TESTED E-UP ALARM?
-
CHECKED/TESTED RESET KEY?
-
CHECKED/TESTED OPEN BUTTON?
-
CHECKED/TESTED UP BUTTON?
-
CHECKED/TESTED UP BUTTON RED INDICATING LIGHT?
-
CHECKED/TESTED DOWN BUTTON GREEN INDICATING LIGHT?
-
CHECKED/TESTED DOWN BUTTON?
-
CHECKED/TESTED CLOSED BUTTON?
-
CHECKED/TESTED POWER FAILURE INDICATING LIGHT?
-
CHECKED/TESTED STOP BUTTON?
REMOTE PANEL
-
CHECKED/TESTED POWER KEY?
-
CHECKED/TESTED POWER INDICATING LIGHT?
-
CHECKED/TESTED E-UP BUTTON?
-
CHECKED/TESTED E-UP LIGHT?
-
CHECKED/TESTED E-UP ALARM?
-
CHECKED/TESTED RESET KEY?
-
CHECKED/TESTED OPEN BUTTON?
-
CHECKED/TESTED UP BUTTON?
-
CHECKED/TESTED UP BUTTON RED INDICATING LIGHT?
-
CHECKED/TESTED DOWN BUTTON?
-
CHECKED/TESTED CLOSE BUTTON?
-
CHECKED/TESTED DOWN BUTTON GREEN INDICATING LIGHT?
-
CHECKED/TESTED POWER FAILURE INDICATING LIGHT?
-
CHECKED/TESTED STOP BUTTON?
GATE ARMS
-
LOCATION OF GATE ARM?
-
IS GATE ARM COMPOSITOR INSTALL IN CONTROL?
-
DOES GATE ARM RAISE WHEN BARRIER IS DOWN?
-
DOES GATE ARM LOWER WHEN BARRIER IS UP?
TRAFFIC LIGHTS
-
DOES "RED" TRAFFIC LIGHT GO ON WHEN BARRIER IS UP?
-
DOES "GREEN" TRAFFIC LIGHT GO ON WHEN BARRIER IS DOWN?
ADDITIONAL NOTES OR COMMENTS (IF NEEDED)
-
ENTER ANY NOTES OR COMMENTS
ELECTRONIC SIGNATURE ACKNOWLEDGE
-
ELECTRONIC SIGNATURE ACKNOWLEDGE, I AGREE THAT MY ELECTRONIC SIGNATURE <br>IS A LEGALLY BINDING EQUIVALENT TO MY HANDWRITTEN SIGNATURE. WHENEVER I <br>EXECUTE AN ELECTRONIC SIGNATURE, IT HAS THE SAME VALIDITY AND MEANING AS <br>MY HANDWRITTEN SIGNATURE. I WILL NOT AT ANY TIME IN THE FUTURE, REPUDIATE <br>THE MEANING OF MY ELECTRONIC SIGNATURE OR CLAIM THAT MY ELECTRONIC SIGNATURE <br>IS NOT LEGALLY BINDING.
-
NASATKA REPRESENTATIVE SIGNATURE
-