Title Page

  • Document No.

  • Audit Title

  • Client / Site

  • Conducted on

  • Prepared by

  • Location
  • Personnel

Site Information

  • Supervisors Name

  • Contract Managers Name

  • Operatives On Site

  • Brief Description Of Works

  • ASB5 Notifiable

  • Start Date

  • Finish Date

1.0 Scope Of Works

  • 1.1 Is there at least one certificated asbestos supervisor as a minimum and as named on the P.O.W and ASB5

  • 1.2 Is the ASB5 correct in detailing of asbestos and quantity as stated in the P.O.W

  • 1.3 Is the total number of persons on site less than or equal to that is stated on the ASB5

  • 1.4 Is the scope of works correctly described in the P.O.W

2.0 Plan Of Works And Documentation

  • 2.1 Does the P.O.W detail the client for the works

  • 2.2 Can you confirm that the wording in the plan of works is clear and concise

  • 2.3 If any changes have been made to the P.O.W, are the correct amendments in place, and have they been agreed with the contracts manager and signed

  • 2.4 Is there a copy of Oracles S.O.P available on site

  • 2.5 Has the supervisor and the operatives on site all signed the P.O.W (Question the operatives on the P.O.W)

  • 2.6 Has the P.O.W been compiled by a competent person and signed off

  • 2.7 Does the P.O.W stated the correct date, and is there an reasonable estimated finish date

  • 2.8 Are the working hours in the P.O.W and ASB5 being worked to

  • 2.9 Does the plan of works state the company providing analytical support and 4 stage clearance

  • 2.10 Does the P.O.W accurately detail the type, condition and form of ACM's

  • 2.11 Does the P.O.W detail the method of works accurately (ie) Removal, Encapsulation, Re-in statement

  • 2.12 Is the correct type of respirator to be used including filters as stated in the P.O.W

  • 2.13 Does the P.O.W detail the arrangement made for witnessing the smoke test

  • 2.14 Does the sketch match the site set up...including DCU, Air/Bag locks, Viewing Panels, CCTV, Waste and Transit Routes

  • 2.15 Are the enclosure dimensions correct and adhered to on site as detailed in the P.O.W

  • 2.16 Does the P.O.W detail entry/exit or transit procedures to be followed during works

  • 2.17 Have all hazards on site been identified with appropriate risk assessments for all to view

  • 2.18 Have chemicals on site been identified and appropriate CoSHH assessments available for all to view

  • 2.19 Where electrical isolations are required, is there suitable certification of isolation

  • 2.20 Is the contractors site diary available for inspection and up to date

  • 2.21 Is there a current medical certificate on site for each supervisor and operative (2 yearly)

  • 2.22 Are the R.P.E check lists filled out prior to use

  • 2.23 Is there a current in date face fit (both masks) available for each supervisor and operative (6 monthly)

  • 2.24 Are supervisors daily checks up to date

  • 2.25 Are the analysts documents up to date and on site

  • 2.26 Has all supervisors and operatives personal paper work been verified and stamped

3.0 Site Set Up And Plant Use

  • 3.1 Have viewing panels and CCTV been set up to view works inside the enclosure as detailed in the P.O.W

  • 3.2 Have adequate warning signs been displayed

  • 3.3 Is the supervisors board clearly on display and showing all current documentation

  • 3.4 Is the works vehicle parked Ina suitable location so as not to inconvenience the public or others on site

  • 3.5 Is there adequate first aid and fire fighting equipment present on site

  • 3.6 Are there at least two H-Type vacuums on site

  • 3.7 Are current copies of DOP's available on site for all individual plant on site, and in date (6 monthly)

  • 3.8 Are all other electrical plant on site PAT (3 monthly) tested and in date

  • 3.9 Does the number of NPU's correspond with that stated in the P.O.W

  • 3.10 Is there sufficient negative pressure within the enclosure

  • 3.11 Is the enclosure getting the adequate air changes stated in the P.O.W

  • 3.12 Is there a H-Type vacuum just inside the enclosure and at least one more within the work area, and does they all work

4.0 RPE and PPE

  • 4.1 Is the RPE in use as stated in the P.O.W

  • 4.2 Are all asbestos supervisors and operatives on site clean shaven

  • 4.3 Are spare filters available on site

  • 4.4 Is the correct RPE being used by all operatives

  • 4.5 DO all masks on site have individual ID tags or serial numbers

5.0 DCU

  • 5.1 Is the DCU positioned as stated in the P.O.W with the transit route as short as possible

  • 5.2 Is the DCU directly connected to the enclosure, if not is thee a valid reason

  • 5.3 Does the power supply have a RCD fitted

  • 5.4 Is there enough storage lockers

  • 5.5 Is the heater working within the DCU

  • 5.6 Are all internal doors self closing with a good seal

  • 5.7 Is the DCU adequately earthed (Easy Plug)

  • 5.8 Is the DCU clean internally and externally

  • 5.9 Is the waste water filtered and being discharged to the closest foul drain

  • 5.10 Date of last filters changed

  • 5.11 Is there adequate hot water

  • 5.12 Are there sufficient 13 amp plug sockets available to charge power packs

  • 5.13 Are there adequate towels and shampoo

  • 5.14 Is there nail brushes within the shower

  • 5.15 Is there a current DOP got the NPU and in date (6monthly)

  • 5.16 Is there a current gas safety certificate (12 monthly)

  • 5.17 Is there a current (NIC) electrical installation certificate (12 monthly)

  • 5.18 Are there sufficient shower heads to allow one per maximum of 4 operatives

  • 5.19 Is the DCU in good condition and free of mould

  • 5.20 Is there a clearance certificate from the last job

  • 5.21 Do the clean and dirty end doors have correct signage

  • 5.22 Does the DCU have a carbon monoxide detector inside the clean end

  • 5.23 Is the dirty end door locked

6.0 Enclosure

  • 6.1 Is the enclosure including air locks and bag locks of sound condition and robust enough to maintain integrity throughout the course of works

  • 6.2 Are the bag locks fitted to the enclosure adequate for the size of ACM's leaving enclosure

  • 6.3 Are the bag locks free from visible debris

  • 6.4 Is the waste route free from visual debris and are all pourers areas adequately covered

  • 6.5 Are the air locks clean and tidy and of correct size as states in P.O.W

  • 6.6 Is there a vision panel to the inner stage of the airlock and bag lock minimum 600mm x 300mm

  • 6.7 Is there sufficient overlap and weighting to flaps of air lock and bag lock to provide suitable potential seal

  • 6.8 On visual inspection was there any holes or breaks in the seal of enclosure, air locks and bag locks

7.0 Observed Works

  • 7.1 Is the dust fibre suppression in use the same as prescribed in the P.O.W, and will it achieve adequate suppression accordingly to the exposure assessment

  • 7.2 Is the waste correctly bagged in enclosure

  • 7.3 IS the waste being correctly double bagged with in the bag lock using suppression and a H-Type vacuum

  • 7.4 Is there a skip on site, is it in good condition with correct signage and locked when not in use

  • 7.5 If there is no skip on site, are there adequate waste consignment notes on site relating to the ACM's being removed

  • 7.6 IS all general non asbestos PPE being worn as stated in the P.O.W

  • 7.7 Is the pre filter the only part of the NPU exposed to the working area

  • 7.8 Are all operatives within the asbestos enclosure wearing the RPE and PPE correctly

  • 7.9 Is the general site well organized and tidy within reason

8.0 Personnel and Company Vehicle

  • 8.1 Do all Oracle Solutions persons on site have ID cards

  • 8.2 Are all Oracle Solutions personnel wearing Oracle branded uniform

  • 8.3 Is behavior of staff or contractors to an acceptable level

  • 8.4 Was the response of the supervisor positive and pro active

  • 8.5 Did operatives respond positively to instruction and advice

  • 8.6 Has the company vehicle check list been completed as required

  • 8.7 Is the vehicle clean internally and externally

  • 8.8 Has the vehicle had a reassurance air test carried out by a qualified analyst within the last 30 days

  • 8.9 Is the waste stored on the van held in waste compartment and way from tools and equipment ect

9.0 Additional Information From Audit

  • Supervisors Signature

  • Auditors Signature

  • Date and Time of Audit Completed

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.