Information
-
Audit Title
-
Document No.
-
Client / Site
-
Conducted on
-
Prepared by
-
Location
-
Personnel
1.0 - Previous inspection
-
1.1 - Has the last inspection been reviewed?
-
1.2 - Are there no outstanding actions?
2.0 - Fire Protection
-
2.1 - Evacuation plan displayed and understood by all employees?
-
2.2 - Flammables stored properly (combustibles away from spark emitting sources)?
-
2.3 - Extinguishers in place, clearly marked for type of fire, with pins secured in place?
-
2.4 - Extinguishers recently serviced? (Check 6 monthly punch mark on tabs.)
-
2.5 - Extinguishers clear of obstructions?
3.0 - General Lighting
-
3.1 - Good natural lighting?
-
3.2 - Light stands provided and in good condition?
-
3.3 - Emergency exit lighting operable?
4.0 - Site Safety Conditions
-
4.1 - Passageways, work areas, stairways, etc, clear of obstructions, and debris?
-
4.2 - Are liquid spills removed quickly?
-
4.3 - Are railings in good condition?
5.0 - Tools and Equipment
-
5.1 - Employees adequately trained for the tool?
-
5.2 - Tools are properly carried and stored?
-
5.3 - Tools are maintained in a safe condition, damaged tools tagged?
-
5.4 - No damaged power tools in use?
-
5.5 - Chop saws: face shield used, fire extinguisher, guards in place?
-
5.6 - No excessive bending or stooping?
6.0 - First Aid Facilities/Safety Permits
-
6.1 - Are cabinets and contents clean/orderly, with no expired products?
-
6.2 - Tool box talks completed and remembered by the employees?
7.0 - Personal Protective Equipment
-
7.1 - Hard hats worn and maintained as required?
-
7.2 - Hearing protection worn as required?
-
7.3 - Required eye protection worn in a proper manner?
-
7.4 - Proper foot protection worn for the job?
-
7.5 - Face shield or goggles worn as required?
-
7.6 - Gloves worn when transporting studs, and other high hazard tasks?
-
7.7 - Dust masks, or respirators used as required for the task?
-
7.8 - Other?
8.0 - Fall Protection
-
8.1 - Body harness worn in a proper manner?
-
8.2 - Lanyards are adequately secured to a suitable anchor?
9.0 Mobile (Perry) Scaffold, Etc.
-
9.1 Terrain clear of obstructions?
-
9.2 - Equipment built within specification, tagged correctly?
-
9.3 - Equipment used according to instructions?
-
9.4 - Competent person on site?
-
9.5 - If used for electrical work are they non conductive? (Wood or fibre glass.)
-
9.6 - For extension ladders are ropes, pulleys and treads in a good state of repair?
-
9.7 - Are proper angles used, with 3' above landing?
-
9.8 - Proper ladders for the job performed/properly secured? (non conductive)
10 - Electrical Safety
-
10.1 - GFCI protected circuit used?
-
10.2 - Cords have current inspection, properly routed, free of defects?
-
10.3 - Ground prongs in place, cords in good condition, cords correct size?
-
10.4 - Power tools unplugged when not in active use?
-
10.5 - Cords, hoses, or welding leads elevated to prevent trip hazards (or properly protected)?
11. Chemical Safety (HAZCOM)
-
11.1 - MSDS available and location known by workers?
-
11.2 - Risk assessments completed for hazardous substances?
-
11.3 - All containers labelled correctly?
Sign Off
-
On site representative
-
Auditor's signature