Title Page
-
Job name
-
Job number
-
Site address
-
Customer name
-
Customer phone number
-
Branch
-
In-house/sub
-
Project manager
-
Salesperson
-
Roof system installed
-
Roof height
Roof deck
-
Decking installed
-
Decking properly installed
-
Decking is in good condition
-
Roof deck appears to be installed to Permaseal spec
Insulation
-
Insulation(s) installed
-
Insulation is dry
-
Insulation is properly secured
-
Insulation is not damaged
-
Insulation meets r value requirements
-
Insulation has proper spacing
-
Insulation taper installed properly
-
Insulation has proper stagger
-
Insulation appears to be installed to Permaseal Spec
Membrane
-
Membrane installed
-
Membrane field secured properly
-
Membrane field has proper number of perimeter sheets
-
Membrane field is free of damage
-
Membrane field has patches on all t-joint intersections and start stops
-
Membrane field is properly welded
-
Membrane flashings welded properly
-
Membrane flashings are free of damage
-
Membrane flashings secured properly
-
All corners welded properly
-
All pipe flashings welded and sealed properly
-
All drains flashed and welded properly
-
All scuppers flashed properly
-
All membrane appears to be installed to Permaseal spec
Termination
-
All terminations are sealed properly
-
All terminations have continuous compression on the applied sealants
-
All termination metal has proper spacing
-
Termination metal has proper number of fasteners
-
Great edge termination base metal installed properly
-
Great edge termination cover installed properly
-
Weldable metal installed properly
-
Sealant pockets installed properly
-
Supplemental termination installed properly
-
All termination metal installed is straight and maintains a new appearance
-
All pipe terminations installed and sealed properly
-
All terminations are damage free
-
All tie offs are sealed properly
-
All terminations appear to installed to Permaseal spec
Drainage
-
Drainage type(s)
-
All drains are properly flashed
-
All drains have proper sealants
-
All drains have continuous compression on sealant ring and gasket
-
Drain studs and nuts are damage free
-
All drain covers present and installed properly
-
All drainage points are free from damage and debris
-
Gutters and downspouts installed properly
-
Roof drainage appears to be installed to Permaseal spec
Roof mounted equipment
-
All HVAC units are supported and flashed properly
-
All skylights are installed and flashed properly
-
All gas lines, conduits, and other rooftop lines are properly supported with proper sheeting
-
All roof top equipment is properly secured
-
All roof mounted equipment appear to be installed to Permaseal Spec