Document No. CA-CS-008

Use this Digital Checklist
Download as PDF
graphic of a hand making an okay sign ×

Free Peter Cations CABLE LADDER INSTALLATION CHECKSHEET Checklist

Use this Digital Checklist

Template Preview

app-store-download play-store-download

GO DIGITAL TODAY
Convert your paper checklists into digital forms

Scan this QR code to use this paper checklist on your smartphone or tablet. Visit www.iauditor.com

Scannable QR Code to download App

Audit

DETAILS

Client / Site: Barwon Water - Black Rock WRP Inlet Works Upgrade 400 Black Rock Connewarre

Inspection Area:

Reference: BW Technical Specification Rev 0 Clause: 38.18 Cable Ladder and Cable Tray 38.25 Earthing

Document No. CA-CS-008 ITP No:

VISUAL CHECKLIST

Marine grade aluminium

GRP

316 Stainless steel

Adequate support on galvanised steel brackets minimum 6 mm thickness

Adequate supports at not more than 2mt centres and intermediate supports at joints

Adequate supports spaced such that the loaded cable tray and ladders does not deflect more than 5mm

Segregation of dissimilar metals using 3mm insulating spacers

All cable trays and ladder fittings, brackets, bolts, nuts, and washers shall be hot dipped galvanised steel and shall match the cable tray and ladder in use

Where cable trays and ladders have been cut or damaged during erection, the resulting exposed metal shall be cold galvanised treated and suitable painted to prevent corrosion

Mounted to maintain 300mm clearance between racks vertically and at least 150mm under structural sections

Cable ladder earthed to the electrical enclosure they originate from or to a metal structure that is earthed

Adequate size to provide 50% spare capacity

All ladder bends, both horizontal and vertical shall have a minimum radius of 450mm for power and control cables

Cable ladder expansion joints installed as per manufacturers requirements

Barrier Strip installed / segregation provided

Cables laid in cable ladder and trays, shall be arranged to minimise cross-overs

Secured at frequent intervals by means of approve metal cable straps of adequate side and strength for the cables involved

Cables tied at suitable intervals on ladder

All cable ties flush cut to eliminate harp edges

Installation neat and evenly spaced

Where cables may be exposed to UV or subject to mechanical damage, peaked covers of similar material shall be clamped to the ladder

Installation does not impede access to walkways

Notes/Comments

APPROVALS

Cable Tray Installation is

Actions to be taken:

Entered on Punch List

Punch list Reference Number:

Item No:

Person Completing the Checklist
  • Greg Grima
  • John Toner
  • Shane Dando
  • David Howard
Signature:
Agfab Approval By:
  • Greg Grima
  • John Toner
  • Shane Dando
  • David Howard
Signature:
Peter Cations CABLE LADDER INSTALLATION CHECKSHEET
Peter Cations

Peter Cations CABLE LADDER INSTALLATION CHECKSHEET

Document No. CA-CS-008

Use this Digital Checklist
Download as PDF
Please note that this checklist is a hypothetical example and provides basic information only. It is not intended to take the place of, among other things, workplace, health and safety advice; medical advice, diagnosis, or treatment; or other applicable laws. You should also seek your own professional advice to determine if the use of such checklist is permissible in your workplace or jurisdiction.

Related checklists

Peter Cations CABLE JUNCTION BOX INSTALLATION CHECKSHEET
Peter Cations
Peter Cations CABLE JUNCTIO...
Document No. CA-CS-009
4 downloads
Peter Cations INSTRUMENT CABLE INSTALLATION AND TEST CHECKSHEET
Peter Cations
Peter Cations INSTRUMENT CA...
Document No. CA-CS-004
2 downloads
Peter Cations CONTROL CABLE INSTALLATION AND TEST CHECKSHEET
Peter Cations
Peter Cations CONTROL CABLE...
Document No. CA-CS-003
5 downloads
Peter Cations VSD INSTALLATION CHECKSHEET
Peter Cations
Peter Cations VSD INSTALLAT...
Document No. CA-CS-0??????????
7 downloads
Peter Cations VSD CABLE INSTALLATION AND TEST
Peter Cations
Peter Cations VSD CABLE INS...
Document No. CA-CS-005
4 downloads
Peter Cations POWER CABLE INSTALLATION AND TEST
Peter Cations
Peter Cations POWER CABLE I...
Document No. CA-CS-002
5 downloads
Peter Cations LEN ENCLOSURE INSTALLATION CHECKSHEET
Peter Cations
Peter Cations LEN ENCLOSURE...
Document No. CA-CS-011
1 downloads
Peter Cations  MOTOR INSPECTION CHECKSHEET
Peter Cations
Peter Cations MOTOR INSPEC...
Document No. CA-CS-0??????????
6 downloads
back arrow for carousel
back arrow for carousel

Don’t start from scratch each day

Use iAuditor to create and update checklists in minutes, deploying to your whole workforce from one application.

Find out how
  • Product
    • Product

    • iAuditor
    • Temperature logging
    • TeamTrain
    • Spotlight
  • Resources
    • Resources

    • Templates
    • Checklists
    • Topics
    • Blog
    • Events & Webinars
    • Apps
    • API
  • Support
    • Support

    • Support center
    • Product updates
    • Book a demo
    • Integrations
  • Company
    • Company

    • About us
    • Careers
    • Meet the team
    • Contact us
Status Privacy & Terms Security
iAuditor Logo Icon ©SafetyCulture 2021