Title Page
-
Site location
-
Inspection date
-
Inspected by
-
Start date
-
End date
-
Project/Programme Reference
- Kitchen
- Bathroom
- WC
- Roofline & RWG
- Roof/Secondary Roof
- Doors
- Windows
- Gas heating/Radiators
- Electric heating
- Rewire/CCU
-
Contractor and site representive
-
Customer Present
-
Smoke alarms?
- House
- Flat
- Bungalow
- Bedsit
- Hall
- Landing
- Landing 2
- Other
- Living room
- N/A
-
Location of gas boiler?
Works Inspection Details
-
Kitchen Upgrade
-
Is there a utility room? If so, please provide photographs. Include comments on the extractor, flooring measurements, number of units, fuse spurs, Sure Stop, and any other relevant details.
-
Are infills/plinths/kickboards/shirting fitted correctly?
-
Are all units, backboards, and end panels properly levelled, free from any damage, with doors correctly aligned, and soft closures appropriately fitted?
-
Are all shelves present and fitted correctly?
-
Are drawers fitted correctly and running smoothly?
-
Have splash backs been installed?
-
Are worktops, joints, edging strips and upstands installed correctly and free from any damage?
-
Are all appliance spaces correct and appliances re-installed correctly?
-
Have cut outs been sealed correctly, service pipe holes the correct size, and copper pipe used?
-
Have isolation valves been fitted and are accessible, including sure-stop where stop tap is located in the kitchen?
-
Has boxing been installed where applicable? If yes note where
-
Has new skirting been fitted?
-
Has C02 alarm been fitted, is in correct position and old one removed?
-
Has new LED lighting been installed?
-
Are fuse spurs labelled correctly?
-
Has an extractor fan been installed?
-
Has vinyl floor been fitted correctly, sealed to the edges and threshold fitted where applicable?
-
Has plastering & decorating been completed to a satisfactory standard?
-
Have radiator(s) and door(s) leaf been painted?
-
Kitchen Snags - Are there any follow up snags? If yes, note how many
- 0
- 1
- 2
- 3
- 4
- 5
- 6
- 7
-
Bathroom Upgrade
-
Have the correct bathroom fixtures/fittings been used? i.e. WHB/BATH/TOILET/BATH PANEL/SHOWER TRAY
-
Have stickers been removed from fixtures and fittings?
-
Have the wall boards, including splashbacks, been installed to a high standard, properly sealed, and free from sharp edges or any finish imperfections?
-
Has the riser rail for the shower and curtain been installed correctly? If any grab bars were previously fitted, have they been reinstalled properly?
-
Is all silicone sealant installed and to a satisfactory standard?
-
Have isolation valves been fitted, accessible and copper piping used?
-
Has vinyl floor been fitted correctly, sealed to the edges and threshold fitted where applicable?
-
Has new skirting been fitted?
-
Has boxing been installed where applicable? If yes note where
-
Has plastering and decorating been completed to a satisfactory standard?
-
Have radiator(s) and door(s) leaf been painted?
-
Has extractor fan, isolator switch, LED light and pull cord been fitted?
-
Bathroom - Are there any follow up snags? If yes, note how many
- 0
- 1
- 2
- 3
- 4
- 5
- 6
- 7
-
Downstairs/additional WC and WHB Upgrade
-
Have the correct bathroom fixtures/fittings been used?
-
Have stickers been removed from fixtures and fittings?
-
Have the wall board for the splashback, been installed to a high standard, properly sealed, and free from sharp edges or any finish imperfections?
-
Is all silicone sealant to a satisfactory standard?
-
Have isolation valves been fitted, accessible and copper piping used?
-
Has new skirting been fitted?
-
Has boxing been installed where applicable? If yes note where
-
Has vinyl floor been fitted correctly, sealed to the edges and threshold fitted where applicable?
-
Has plastering and decorating been completed to a satisfactory standard?
-
Have radiator(s) and door(s) leaf been painted?
-
Has extractor fan, isolator switch been fitted, LED lighting and pull cord installed?
-
DSWC - Are there any follow up snags? If yes, note how many
- 0
- 1
- 2
- 3
- 4
- 5
- 6
- 7
-
Window Replacement Checklist
-
Type of window installed
- UPVC
- Timber
-
Have all windows been installed to a high standard, properly sealed, free from any damage or scratches, and fitted with the correct type of glass?
-
Are all windows operating correctly, trickle vents operational and restrictors present and functional?
-
Has all making good been completed to internal areas around windows?
-
Has all making good been completed to external areas around windows?
-
Are window handles a push button with no locks/keys? If no, please verify whether the customer was provided with keys and kindly request their return.
-
Windows - Are there any follow up snags? If yes, note how many
- 0
- 1
- 2
- 3
- 4
- 5
- 6
- 7
-
Dwelling Door(s) Replacement
-
Door location?
- Front
- Rear
- Patio
- French door
- Communal door- Main door
- Communal internal door
- Store
- Other
-
Door material?
- UPVC
- Composite
- Fire
- Timber
- Other
-
Does the door open and close freely?
-
Does the lock secure the door firmly within the frame, and are both the thumb turn and door chain present?
-
Are all door numerals, handles, letter-plate, door viewer present and correctly fitted?
-
Has the customer received all the keys or received communal key/information?
-
Has all making good been completed?
-
Dwelling Door(s) - Are there any follow up snags? If yes, note how many?
- 0
- 1
- 2
- 3
- 4
- 5
- 6
- 7
-
Fire doors - Flats and communal doors
-
Door location?
- Front
- Rear
- Patio
- French door
- Communal door- Main door
- Communal internal door
- Store
- Other
-
Door material?
- UPVC
- Composite
- Fire
- Timber
- Other
-
Are labels or markers present and indicate that the door is certified?
-
Does the door open and close freely? Is a mechanical door closer present, in good condition and free from damage?
-
Are there 3 or more hinges present with no missing screws?
-
Are there any gaps around the door frame?
-
Does the lock secure the door firmly within the frame, and are both the thumb turn and door chain present?
-
Are all door numerals, handles, letter-plate, door viewer present and correctly fitted?
-
Has the customer received all the keys or received communal key/information?
-
Has all making good been completed?
-
Fire door(s) - Flats/Communal - Are there any follow up snags? If yes, note how many?
- 0
- 1
- 2
- 3
- 4
- 5
- 6
- 7
-
RWG/Roofline - THIS DOES NOT INCLUDE FULL NEW ROOFS
-
Have damaged tile been replaced? If yes how many?
-
Have gutters been renewed and fitted correctly?
-
Have the downpipes been replaced and installed correctly, with all clips in place? Please also note the number of downpipes?
-
Have fascia's & soffits been replaced and installed correctly?
-
Have the satellite dish and BT cables been reinstalled and tidied up where applicable?
-
Does the dwelling have a porch?
-
If yes have RWG/Roof works been completed for porch?
-
RWG/Roofline only - Are there any follow up snags? If yes, note how many
- 0
- 1
- 2
- 3
- 4
- 5
- 6
- 7
-
Main roof replacement and RWG
-
Type of roof?
- Pitched
- Flat
- Thatched
- Other
-
Have the roof correct tiles/materials been used?
-
Has the valley been pointed and free from debris?
-
Has dry verge been installed?
-
Has the verge or ridge been re-pointed? Include approx. measure
-
Have gutters been renewed and fitted correctly?
-
Have the downpipes been replaced and installed correctly, with all clips in place? Please also note the number of downpipes?
-
Have fascia's & soffits been replaced and installed correctly?
-
Have the satellite dish and BT cables been reinstalled and tidied up where applicable?
-
Does the dwelling have a porch?
-
If yes have RWG/Roof works been completed?
-
Main roof replacement and RWG - Are there any follow up snags? If yes, note how many
- 0
- 1
- 2
- 3
- 4
- 5
- 6
- 7
-
Secondary Roof Replacement & RWG
-
Type of secondary roof?
- Porch
- Outbuilding
- Store cupboard
- Other
- N/A
-
Type of roof?
- Pitched
- Flat
- Thatched
- Other
-
Have correct tiles/materials been used?
-
Has the valley been pointed and free from debris?
-
Has dry verge been installed?
-
Has the verge or ridge been re-pointed? Include approx. measure
-
Have gutters been renewed and fitted correctly?
-
Have the downpipes been replaced and installed correctly, with all clips in place? Please also note the number of downpipes?
-
Have fascia's & soffits been replaced and installed correctly?
-
Have the satellite dish and BT cables been reinstalled and tidied up where applicable?
-
Secondary Roof - Are there any follow up snags? If yes, note how many
- 0
- 1
- 2
- 3
- 4
- 5
- 6
- 7
-
Electrical rewire and CCU Checklist
-
Have the correct number of sockets been installed in each room, including 2 USB sockets?
-
Have all chasings been patched in correctly and to a suitable standard?
-
Has new consumer unit been installed, accessible and labelled correctly?
-
New light switches and light pendants been installed throughout?
-
Take photo of meter
-
Rewire/CCU - Are there any follow up snags? If yes, note how many
- 0
- 1
- 2
- 3
- 4
- 5
- 6
- 7
-
Heating Upgrade Checklist
-
Does boiler appear to be fitted correctly?
-
Flue type?
-
Has the flue been installed correctly (not boxed in) and sealed externally?
-
Is all pipework neat and tidy and suitable clipped to the wall?
-
New radiators installed and how many radiators in property?
-
Do all radiators have new TRV's and lock shields installed?
-
Has timeclock and programmer/thermostat been installed and working correctly?
-
Heating/Rads - Are there any follow up snags? If yes, note how many?
- 0
- 1
- 2
- 3
- 4
- 5
- 6
- 7
-
Storage Heating /Other Heating Checklist
-
Type of heater installed?
-
How many of each heaters have been installed?
-
Are heaters installed correctly and free from damage?
-
Are heaters floor mounted and fixed to the wall?
-
Water tank location? Take photo
-
Has customer been shown how to use system/heaters?
-
Has making good been completed where old heater has been removed?
-
Electric heating - Are there any follow up snags? If yes, note how many
- 0
- 1
- 2
- 3
- 4
- 5
- 6
- 7
General Site Details and Sign Off
-
Has the site been left clean and tidy?
-
Has all waste been removed?
-
Is scaffolding present?
-
Has customer reported any issues?
-
Has customer answered satisfaction survey?
-
Overall inspection rating?
-
Places for People Initials
-
Contractor Initials
-
Customer Initials