Piping Pre-commissioning Checklist

FLOODING SPREAD SET-UP

  • Conduct JSA

  • Obtain Work Permits

  • Check Flooding Procedure on hand

  • Assemble equipment to drawing

  • Check communications with dive team

  • Check fuel, oil and water in flooding pump skids and diesel generators

  • Check adequate chemicals and chemical injection spread operational and ready.

  • Check flooding spread valve positions

  • Secure flooding hoses and connections

  • Lower hoses down to the launcher head and confirm connected

  • Confirm position of launcher head valves

  • Function test submersible lift pumps and diesel flooding pumps

  • Check pressure chart recorder is wound up and signed, dated flooding chart inserted

  • Prepare flooding, chemical injection and pipeline pigging logs

  • Confirm the pipeline pig configuration in the launcher head

  • Advise Client approved representative ready to start flooding operations

PIPELINE PIG VALVE LAUNCHING SEQUENCE

  • Diesel engines on generator and pump skids started

  • Confirm flooding hose connected and secured to launcher head and topside

  • Engage submersible and flooding pumps

  • Pig Launcher Valves No. 2, No.3 confirmed shut by dive team

  • Pig Launcher Valve No. 1 main supply Ball Valve confirmed open by dive team

  • Inject seawater approximately equivalent to 200m of linear pipe volume for flushing into the pipeline through valves 1

  • Dive team open valve 2, then close valve

  • 8 Inject seawater approximately equivalent to 200m of linear pipe volume for flushing into the pipeline and launch pig 1

  • Dive team open valve 3, then close valve 2

  • Inject seawater approximately equivalent to 200m of linear pipe volume for flushing into the pipeline and launch pig 2

  • Chemically treated water will be pumped into the pipeline behind pig 2

  • After 5 mins, open launcher valves 1, 2, and 3 pump pigs to the receiver

PIPELINE FLOODING, PIGGING, GAUGING AND CHEMICAL INJECTION

  • Check pipeline pigs’ home via volumetric calculation

  • Confirm pipeline flooded by pressure spike on pressure chart recorder chart or by pig indicator or by pumping 1.5x total pipeline volume

  • Disengage flooding pumps and turn off submersibles

  • Allow diesel engines 5-minute no load condition and shut off flooding pump skid

  • Switch off submersible pumps and diesel generator

  • Check flooding, chemical injection, pipeline pigging logs and ITPs signed by Client Rep

  • Flooding Pressure chart recorder signed by Client Rep

  • Confirmed flooding hoses depressurized to atmosphere pressure and disconnect prior to disconnection by dive team

  • Dive team confirm flooding hose depressurized prior to disconnection

COMPLETION

  • Additional Comments

  • Inspected by:

  • Approved by:

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.