Title Page
-
Conducted on
-
Prepared by
Ensure RPA bracket must be present
-
Verify machine will not cycle: Do not load LH BSD bracket (#3383)
-
Verify machine will not cycle: Do not load RH BSD bracket (#3382)
Ensure correct valance must be present
-
Verify machine will not cycle: For a fascia requiring a V6 lower (#504), Load fascia with V8 lower valance (#505)
-
Verify machine will not cycle: For a fascia requiring a V8 lower (#505), Load fascia with V6 lower valance (#504)
-
Verify machine will not cycle: For a V6 fascia (#504) not requiring RPA, Load V6 lower valance (#504) with RPA
-
Verify machine will not cycle: For a V8 fascia (#505) not requiring RPA, Load V8 lower valance (#505) with RPA
Ensure AP sensor is functioning as expected
-
Verify machine will not cycle: Do not apply AP to LH side
-
Verify machine will not cycle: Do not apply AP to RH side
Ensure tape backing vacuum chute is functioning as expected
-
Verify machine will not cycle: Do not place tape backing through LH vacuum chute
-
Verify machine will not cycle: Do not place tape backing through RH vacuum chute