Title Page

  • Location
  • Conducted on

  • Prepared by

  • Barrier as installed

  • 1. Height 1200mm min approach side AFGL. Including 500mm clear below 900mm NCZ-1, NCZ-2 Cl.2.2.2 & 2.3.1

  • 2. Member Spacings 100mm max vertical & horizontal openings (test-Strength & Rigidity of openings Cl.3.1) Cl.2.3.6

  • 3.Ground Clearance 100mm max Gap ≤ 100mm under barrier Cl.2.3.7

  • 4.Stabilised Ground Surface no loose ground, sand, pebbles, chip-bark etc. directly under barrier Cl.2.3.7

  • 5.Stepped/Staggered Fencing Panels NCZ 900mm arc Cl.2.3.5 b&c

  • 6.Material Durability Fit for purpose – will not deteriorate, degrade prematurely Cl.2.1

  • 7.Glass Barriers certificate of compliance from manufacture or complies AS1288 - “A” Safety Grade – 10mm Cl.2.3.3

  • 8.Intersecting Barriers-NCZ’s 300mm inside/900mm outside. where intersect. angle > 900 extend 900mm Cl. 2.2.5

  • 9.Surface finish no sharp edges or projections to cause injury or harm - e.g. exposed fixings Cl.2.1

  • 10.Outside NCZ-1&2&3 - 900mm no climbable objects on or within 900mm arc eg. Trees/plants, pots, furniture Cl.2.2.2

  • 11.Inside NCZ-4 - 300mm no climbable objects on or within inside 300mm Horz. & 900mm Vert. Cl.2.2.2d

  • 12.Hand & Foot-Holds no project/indent >10mm wide on surface NCZ-1 or within 900 NCZ-2&3&4 600 slope Cl.2.3.4

  • 13.Perforated Material/Mesh apert≤13mm-1200mmHigh / apert >13≤100-1800mmH - measure Horiz widest part Cl.2.3.2

  • 14.Perforated Mat’l/Mesh test not reduce height 25kg@top/not lifted by100N force & reduce bottom gap &Flex test 2.3.2e

  • 15.Strength Posts & Footings withstand Horz. Steady force 330N @1200mmH for 30 seconds (incl.glass fence)Cl.3.2

  • 16.Strength-Flexible comp withst.9.1kg Dynamic ᴓ50mm ½ sphere &1400mm Pendulum @ 400 Fabric,Brushwood,Wiremesh 3.3.2

  • 17.Strength-Rigid components withstand 50&330N static force 30sec Steel,Aluminium,Wood,Glass,Acrylic,Masonry 3.3.1

  • 18.Strength & Rigidity of openings vert & horiz-ᴓ105mm/20mm cone not pass through with upto150N steady force 3.1

Gates & Latches Clause 2.4

  • 19.Direction of Gate Swing must open outwards / swing away from the pool area Cl.2.4.1.1

  • 20.Self-Closing & Latching any position & resting on latch after 30sec 25kg mass/100mm from edge-latch side Cl.3.4

  • 21.Latch Release Outside Height 1500mm min. AFGL Cl.2.4.2.2 & 2.4.2.3

  • 22.Latch Release Inside Reach Over Height 1200mm min AFGL latch 150mm down from top of gate Cl.2.4.2.2

  • 23.Hinges & Springs Not Climbable 900mm apart if greater than 10mm wide hand/foothold < 600 slope Cl.2.4.3

  • 24.Shielding/Tampering latch not able to be tampered, 150mm from top, < 10mm gap, 450 radius Cl.2.4.2.3

  • 25.Gap Under Gate ≤ 100mm to a solid/permanent ground finish – no loos materials Cl.2.4.1.1

  • 26.Latch Device not able to be adjusted without use of tool, nor locked/latched in open position Cl.2.4.2.1

  • 27.Gate not capable propped opened no potential latching device to keep gate in open position Cl.2.4.1

  • 28.Hanging of Gate not lifted/pulled down causing release of latch or gate unhinge or increase bottom gap>100 250N Force

  • 29.Glass gate with pivot hinges 50mm gap min b/w 900mm from 1100 down from top (finger entrapment) Cl.2.3.3

Internal Doors open outwards - away from pool External doors not permitted except for indoor pools Cl.2.7

  • 30.Latch Release Height 1500mm min AFFL. Top of NCZ-1 shall be ≤ 1200mm AFFL Cl.2.7d&e

  • 31.Self-Closing & Latching from any position without manual force & resting on latch Cl.2.7a&b

  • 32.Door not capable propped opened no potential latching device fitted to keep door in open position Cl.2.7c

  • 33.Projections/Indentations on door ≤10mm none within 900NCZ anywhere b/w floor & 1200mm AFFL Cl.2.7e

Windows Applies to all openings into pool area < 1800mm AFGL from pool area. Note: Standard nylon flyscreens not accepted Cl.2.6

  • 34.Restrict opening ≤ 100mm max no keyed locks / sliders not lifted out Test - Strength & Rigidity of openings Cl.2.6b

  • 35.Mesh/bar screens securely fixed window<1800 AFGL- Metal wire type & must be permanently fixed by tool 2.6a

Boundary Fencing 1800mm AFGL on pool side & 900mm NCZ-5 on inside face + 500 clear for height 2.2.4 + 2.3.

  • 36.Height 1800mm min measured from pool side, Inside face 900mm NCZ5 - outside face can be climbable Cl.2.2.4

  • 37.900mm NCZ-5 down from top of fence from pool side–500mm clear zone below NCZ to maintain effective height

  • 38.Pool Barrier Intersect Boundary Fence b/t 45&1350 &pool barrier top≤50mm wide OK. Otherwise extend 900m 2.2.4

  • 39.Strength & Rigidity In-good service condition - no loose, split, cupped palings-sustain 330N Static force. Rigid test

Retaining walls<1800mmH NCZ1&2 apply&intersections,900mm wing/cantilever section,150 max slope. Cl.2.5

  • 41.Retaining Walls > 1800mm NCZ1&2 not required below pool – not slope towards/above-not slope away pool >15 degrees

  • 42.Balconies Balcony floor > 1800mmAGF & not project within NCZ-3 of pool barrier. Otherwise pool barrier Req. Cl.2.8

  • 43.Above Ground Pool/Spa filtration pump system, ladder, bracing protected i.e. non-climbable wall 1200H

  • 47.Swimmin Swimming Pool sited in accordance with the approved plans?

Comments

  • Additional Media

  • Additional Comments

  • Highest Risk Observed

Completion

  • Inspection Completion Time

  • Sign

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.