Report Information
Pool Water Treatment - Site Audit
-
For which Site
- Batley Baths & Rec
- Batley Sports & Tennis
- Colne Valley
- Dewsbury
- Holmfirth
- Huddersfield
- Scissett
- Spenborough
- Stadium
-
Audit of Main Pool Plant, Spa Pool or Both?
- Main Pool
- Spa Pool
- Main & Spa Pool
-
Date completed
-
Signed by:
Overview
Audit Summary / Overview of Main Findings
Section 1
Pool Plant Operators
-
Is there a Level 2 Operator/s on Site?
-
Name Level 2 Operators:
-
Suggested Action:
-
Name Level 1 Operators on Site:
-
Are all Level 1 Operators fully signed off as Competent?
-
Suggested Action:
Safety of Pool Plant Operators
-
Is there a system/procedure for lone working in the Plant Room?
-
Suggested Actions?
-
Is there a First Aid kit in the Plant Room or Close by?
-
Suggested Actions?
-
Is there an Eye-Wash station within easy reach of all Chemical Storage areas & any areas of Chemical Use?
-
Suggested Actions?
-
PPE available and suitable for tasks being performed?
-
Suggested Actions?
-
All Operators have their own individual PPE?
-
Suggested Actions?
-
PPE is in Good condition?
-
Suggested Actions?
-
PPE is suitably stored?
-
Suggested Actions?
-
There is evidence of suitable PPE being used correctly by Operators every time?
-
Suggested Actions?
-
There is a suitable stock of spare PPE items?
-
Suggested Actions?
Pool Chemical Storage & Safety
-
Storage of HTH stock suitable & Safe?
-
Suggested Actions:
-
Storage of PAC Stock suitable & safe?
-
Suggested Actions:
-
Storage of CO2 suitable & safe?
-
Suggested Actions:
-
HTH Daytank / Feeder-System suitable & safe?
-
Suggested Actions:
-
Bunding / Drip-Trays are in place and are suitable & safe?
-
Suggested Actions:
-
Evidence of spillages on or around HTH Daytank?
-
Suggested Actions:
-
Is there evidence of a Spillage Procedure in place & being followed/used?
-
Suggested Actions:
-
Is there evidence that the KAL Manual-Dosing Procedure is being followed fully?
-
PAC Dosing unit is suitable & safe?
-
Suggested Actions:
-
Evidence of spillages on or around PAC Dosing unit?
-
Suggested Actions:
Maintenance of Pool Plant
-
Are Plant Room areas Clean & Tidy?
-
Suggested Actions:
-
Are PPM Checks & Tasks being performed?
-
Suggested Actions:
-
Are dosing systems being flushed and cleaned monthly?
-
Suggested Actions:
-
Is there a suitable stock of dosing system spares available?
-
Pump Diaphragm?
-
Injector?
-
Injector Spares?
-
Foot-Valve assembly?
-
Spare Dosing Line?
-
Sample line filters (gauze or cartridge)?
-
Are all valves working? Are all valves being operated weekly to prevent seizure?
-
Suggested Actions:
-
Is Sample-Line Filter being suitably maintained?
-
Suggested Actions:
-
Is Sample-Cell being suitably maintained?
-
Suggested Actions:
-
Is Flow-Meter working? Is it being maintained?
-
Suggested Actions:
-
Are gauges working? Are they being calibrated annually?
-
Suggested Actions:
-
Walk Plant Room checking for faults/leaks. Ask Staff if there are any 'Live' faults/leaks currently.
-
Are there any faults/leaks?
-
Have faults/leaks been reported? Are they being Actioned?
-
Suggested Action:
-
Detail:
Pool Water Testing Station / Equipment
-
Is the Pool Testing station clean & tidy?
-
Suggested Action:
-
Is the Pool Water Testing equipment suitable, working & fit for purpose for all Tests being performed?
-
Suggested Action:
-
Is the Photometer and other testing equipment clean & hygienic?
-
Suggested Action:
-
Check the Calibration of the Photometer & TDS Meter:
-
Is the Photometer and TDS Meter calibrated?
-
Suggested Action:
-
Is there a suitable Test Tablet stock and is it being rotated?
-
Suggested Action:
-
Are the correct Control Forms in use and being used correctly?
-
Suggested Action:
-
Is the ISRM/CIMSPA Pool Testing Guidance Poster in place?
-
Suggested Action:
Spot-Check of Pool Water Tests (sampling exercise - 6 x Tests)
-
Sample Test 1
-
Result from Sample Test 1
-
Is there a record of Action taken?
-
Was the Action correct and in accordance with procedure?
-
Give Detail:
-
Sample Test 2
-
Result from Sample Test 2
-
Is there a record of Action taken?
-
Was the Action correct and in accordance with procedure?
-
Give Detail:
-
Sample Test 3
-
Result from Sample Test 3
-
Is there a record of Action taken?
-
Was the Action correct and in accordance with procedure?
-
Give Detail:
Pool Water Weekly Testing & Monitoring
-
Are the full range of Weekly Tests being performed each week?
-
Suggested Action:
-
Water either Balanced or appropriate Action has been taken & Recorded?
-
Suggested Action:
-
Is a Manager Reviewing the test results and completing the KPIs each week?
-
Suggested Action:
Pool Water Quality - General
-
Has a weekly Subjective Pool Water Assessment been performed and recorded?
-
Suggested Action:
-
Have any concerns been recorded that warrant further investigation?
-
Details:
-
Were concerns noted by Management and Actioned appropriately?
-
Detail:
-
Suggested Action:
Section 2
Backwashing
-
Is there a written Backwash Procedure?
-
Suggested Action:
-
Is the written Backwash procedure in the correct format?
-
Suggested Action:
-
Is the Backwash always performed at the end of the day?
-
Suggested Action:
-
Is the Backwash being performed in accordance with general KAL Backwashing procedures?
-
Suggested Action:
Pool Tank & Pool Area
-
Is the Top-Tile and Pool Bottom/Tank being cleaned at suitable frequencies?
-
Suggested Action:
-
Are the Poolside and surrounding areas visibly clean during audit?
-
Suggested Action:
-
Is the Pool Bottom & Tank clean?
-
Suggested Action:
-
Do the Pool Inlet and Outlet Grills appear to be fully in place?
-
Suggested Action:
-
Have Inlet & Outlet Grills been inspected/tested annually and recorded?
-
Suggested Action:
-
Where a Balance-Tank is part of the system, has it been routinely inspected, cleaned and maintained annually?
Pool Plant / Plant Room - General
-
Is the Chemical Dosing Pump of a suitable type and does it appear to be dosing effectively?
-
Are chemical dosing lines correctly routed, within conduit and without drops/loops/traps?
-
Suggested Action:
-
Do Injectors and Daytank Foot-Assemblies appear to be in good working condition?
-
Suggested Action:
-
Does the Chemical Controller appear to be in good working condition/well maintained?
-
Suggested Action:
-
Do the Filters appear to be in good working condition? No evidence of Sand-egress? Air-release valves working?
-
Suggested Action:
-
Have the Pool Filters been inspected annually? Has the Sand been topped up or replaced if required?
-
Suggested Action:
-
Are the Strainers in good working order? Airtight/sealable? Functioning air-release valve? Functioning Drain valve? Basket in good condition?
-
Suggested Action:
-
Are the Pumps in good working order? Capable of 100% duty even if one Pump fails?
-
Suggested Action:
-
Where an Air-Scour Compressor is fitted is this fully functioning?
-
Is there a fully working Flow-Meter? Is the current Flow-rate line with recommendations?
-
Suggested Action:
Pool Water related Incidents
-
Discuss with Operations or Aquatics Manager:
-
Ask if there have been any faecal/vomit/bodily fluid release incidents in the last 6 months?
-
Details:
-
Are Management Staff familiar with the correct Actions for different 'release' incidents?
-
Suggested Actions:
-
Check Pool Water Log:
-
Have there been any records made of any faecal/vomit/bodily fluid release incidents in the last 6 months?
-
Details:
-
Were the Actions taken correct for the particular incident/s recorded?
-
Suggested Action:
Management of Water Hygiene & Quality
-
Are Bather Hygiene Posters in place and in suitable locations?
-
Suggested Action:
-
Are Bathers practicing bather-hygiene?
-
Suggested Action:
-
Is there any evidence of proactive promotion of bather-hygiene?
-
Suggested Action:
-
Is there a single Manager/Supervisor who has been given responsibility for Pool Water Quality?
-
Suggested Action:
-
Is there a planned programme for the proactive management of Pool Water Quality at Site?
-
Suggested Action:
-
Is the fresh water dilution rate being measured and recorded?
-
Suggested Action:
-
Is the fresh water dilution rate achieving 30 litres per bather?
-
Suggested Action:
-
Is the Pool Plant achieving acceptable/good water condition throughout opening hours?
-
Suggested Action:
-
Is consideration given to busy periods (e.g. school holidays) and appropriate site-specific adjustments made to Pool Water Treatment?
-
Suggested Action:
Heating & Ventilation (Pool-related)
-
Is the Poolside Air Temperature within acceptable parameters?
-
Suggested Action:
-
Is the Water Temperature within acceptable parameters?
-
Suggested Action:
-
Is there sufficient air turnover to keep chlorine odours acceptable?
-
Suggested Action:
Further Notes