INSTRUCTIONS 1. Please answer the questions below. 2. Add Photos in ""Images"" and Comments in ""Notes"" on each question. 3. Add a Corrective Measure in ""Action."" Provide a description, assign to a member, set priority, and due date 4. Complete the audit by providing a digital signature 5. Share your report by exporting as PDF, Word, Excel or Web Link.
-
Client:
-
Project SO# :
-
Project Name:
-
Site Address:
-
Site Contact:
-
Commissioning Conducted Date:
System Type:
-
Asset Photo
Client Specific, General, & Functionality
Client Specific
-
- Has the room account been created, and activation code and/or credentials been provided and entered into the Touch Panel successfully? (MAC reservation, Client LAN Ports provided)
-
- Client provided provisions. (Power, Lectern)
-
- Client provided network. (Ports, switches, etc.)
-
- Clarify if there is access to codec's web interface at client site and/or remotely.
-
- What UC Platform will be utilized? (MTR, Zoom, Webex)
-
- Additional UC services/licenses, call manager.
Physical System Installation
-
- Document any OFE equipment and verify if it matches the drawings. Document any inconsistencies and inform Designer and Programmer.
-
- All devices mounted square and level.
-
- Provide photos of all devices installed, that are visible, showing they are square and level.
-
- Speakers properly installed, configured for appropriate room coverage for the standard listener.
-
- All equipment is securely fastened on mounts as specified.
-
- Provide photos of equipment mounted.
-
- Provide photo evidence from the room's four corners. (Room is clean and ready for use by client)
-
- System and components are serviceable with cable management.
-
- Cables and devices are labeled in agreement with the project drawings.
-
- Provide photo(s) showing cables and devices are properly labeled and dressed.
Functionality Testing
-
- System wakes up and operates as designed; via occupancy or engaging Touch Panel.
-
- Sources route properly to the room display(s).
-
- System touch control panel provides full functionality as designed.
-
- Full system tested and ready for commissioning
Audio and Video
Audio Testing
-
- Record average noise floor; A-weighted, at multiple locations. (Above 45 dB would be a fail and create an action item)
-
- Nominal operation levels:<br> A - 66 dB SPL for conference speech (include reading)<br> B - 60 dB SPL for program material include reading)<br> C - Broadcasted sound only varies +/- 3 dB SPL. Include Reading (should not exceed 6 dB)
-
- Audio Readings
-
- 70% default volume, is the received far side speech at or about 64-66 dB SPL.
-
- Speakers do no produce any crackling, humming, a ring, or any other distortion.
-
- Mute sync from control works as designed.
-
- External call can be added to a meeting without causing an echo.
-
- Ceiling array microphones gain structure and room coverage configured for unity gain.
Video
-
- The system displays stable images, with no scaling-related issues when switching sources.
-
- All sources can be routed to expected destinations.
-
- Cameras configured correctly, and speaker tracking works as designed.
-
- Displays power on/off at system startup and shutdown.
Final Sign Off
-
- Record non-conformances for corrective actions.
-
- All equipment maintain its configuration after a power failure simulation.
-
- Client has been trained on the system or has a training been scheduled/offered. (Include Date)
-
- All relevant equipment firmware and end user credentials been recorded in the AV9000
-
- All serial numbers, MAC addresses, and available IP addresses been recorded in the AV9000.
-
- Commissioning test call has been recorded and included in closeout documents.
-
- Closeout documents have been completed and are ready for delivery to client.
-
- Commissioning Completed On:
-
Upon successful completion of this commissioning document crafted by Presidio representatives, this site is considered completed based on SOW.
-
Presidio Signature:
-
Client Signature: