Title Page
-
Site name
-
Date attended
-
Engineers name
WALK IN COLDROOMS
-
Check on condition and report any defects
-
Test high and low pressure switches
-
Check condenser fan motors, check blades for vibration and adjust & service
-
Inspect refrigerant sight-glasses for moisture and refrigerant charge
-
Clean unit & housing
-
Clean condenser (OFN where appropriate and where access available OOH)
-
Test operation of plant, isolators and emergency stop buttons
-
Inspect pipework and joints for wear and leakage
-
Leak check – F-Gas (where applicable and where access available OOH)
-
Inspect all electrical fittings, cables, plugs and circuits for safe operation
-
Check on plant-room ventilation
LANGERS, STANDALONES AND UNDERCOUNTERS
-
BEFORE AND AFTER PHOTOS MUST BE ADDED
-
Check on condition and report any defects on the worksheet
-
Check all electrical cables, fittings and circuit protectors
-
Leak check – Condensing unit, evaporator and associated pipework
-
Check defrost heaters and defrost cycle settings and thermostats
-
Check peration of electronic controller
-
Check condition of all case panels and doors
-
Clean and check the condensate drain pan or if it has a pump then clean and check the pump
-
Clean condenser (OFN where appropriate)
-
Clean evaporator coil, drain pan & condensate tray
-
Check door gasket
-
Check lighting
AIR CONDITIONING
-
BEFORE AND AFTER PHOTOS MUST BE ADDED
-
Check operation of system in heating and cooling mode
-
Check condition and operation of remote-control unit
-
Remove fascia grille & filter on the internal unit and clean
-
Remove fan blade on the internal unit and clean
-
Clean internal coil
-
Apply drain pan chemical cleaner
-
Clean & check operation of internal drain lift pump
-
Clean and check external drain pump or gravity drain
-
Check air-flow differential across coils (cooling 8-10, heating 10-15 differential)
-
Check & tighten electrical connections
-
Leak check – F-Gas (where applicable)
-
Clean condenser and housing (OFN where appropriate and where access available OOH)
VENTILATION
-
Isolate unit at main and local electrical supplies
-
Vacuum clean grills and wipe clean accessible area
-
Check extract fan motor operation and clean
ICE MACHINE (Where applicable)
-
Chemical clean
-
Flush system
-
Run and dispose of first harvest
DOOR HEATER
-
Isolate unit at main and local electrical supplies
-
Vacuum clean heaters and fans before blowing through with OFN
-
Check fan motor mounts and tighten if required
-
Check all electrical terminals and condition of unit wiring
-
Refit unit housing and run unit on test
-
Check current draw on heaters and fan motor
-
Isolate electrically refit electrical covers and clean exterior of unit
-
Switch on unit and test operation of remote control
Any additional comments
-
Any additional comments