Information
-
Client / Site
-
Conducted on
-
Prepared by
-
Unit
General
-
ADDC Permanent Power Supply Connected
-
ADDC Permanent Water supply Connected
-
NCR and SOR closeout completed
-
Consultant snags Reports completed
-
Final Testing and Commissioning completed and T&C Reports for all systems provided
-
Warranties certificates, O&M and As built drawings are provided from Contractor<br>
-
Smoke/heat detectors are functional<br>
-
All services clearly labelled (Pipes, Cable trays, Cables etc..)<br>
-
3 Keys set provided for all rooms<br>
-
All ducting are sealed with fire sealants and tagged<br>
-
Access panels are functional and adequate for accessing assets/services<br>
-
Cooker installed and functional<br>
-
Distribution board is clean and tidy<br>
-
Dishwasher installed and functional<br>
-
Other white goods installed and functional<br>
-
All AC Equipment are operational<br>
-
All AC Equipment in Auto Mode<br>
-
Extract Fans are in Auto Mode<br>
-
Load schedules available inside DBs<br>
-
All Electrical Sockets, Switches, Isolators labelled<br>
Civil, Joinery and Aluminium work
-
Are all doors/door frames free of scratches and in good condition?<br>
-
Are all doors gaps with in tolerance?<br>
-
Are all doors closing properly?<br>
-
Doors- Alignment of shutter, ironmongery and <br>Architrave
-
"Doors- No colour variance between architrave and shutter <br>or in the veneer itself"<br>
-
Doors- Approved hinges, no rust or screw missing<br>
-
Doors- Approved Ironmongery without any rust <br>
-
Is the flooring tiles/parquet in good condition?<br>
-
Is the floor grouting colour consistent?<br>
-
Is floor grouting free of gaps?<br>
-
Tiles Colour variation & texture variation<br>
-
Slopes in wet areas towards floor drains<br>
-
Are all wall corners aligned and straight?<br>
-
Is termination between wall and ceiling are straight and with good finishing?<br>
-
No undulation was observed on walls and ceiling<br>
-
Is the grouting and silicon in the kitchen in good condition?<br>
-
Are all doors and kitchen cabinets free of scratches and in good condition? <br>
-
Are all cabinets cleaned and free of construction material?<br>
-
Wardrobes & cabinet- No colour variation in the shutters<br>
-
Wardrobes & cabinet- Gap between shutters is equal and uniform<br>
-
Wardrobes & cabinet- Hinges No rust, no missing screw<br>
-
Wardrobes - Uniform joint Architrave<br>
-
"Wardrobes & cabinet - Carcass No scratches No damages and all screw <br>caps are fixed"<br>
-
Wardrobes - Joints of carcass properly terminated <br>
-
"Wardrobes - Shelves in Alignment with no damages or <br>chipping "<br>
-
"Wardrobes & cabinet- Drawers to be in Alignments and No scratch, <br>dent or other damages"<br>
-
"Wardrobes - LED Lights if available to be checked in sensor <br>upon opening and closing"<br>
-
"Cabinet shelves in Alignment with no damages or <br>chipping"<br>
-
"Kitchen Countertop Marble/granite No stains, <br>Not chipped or broken or cracked"<br>
-
"Termination of countertop with adjacent surfaces <br>and back splash (proper uniform application of <br>silicon)"<br>
-
"Cutting of countertop for the sink hole to be <br>properly done and the around finishing should be <br>adequately done"<br>
-
"Countertop edges to be chamfered uniformly and <br>as per approved sample"<br>
-
Sink clear from scratches and stains <br>
-
Mixers to be fixed firmly<br>
-
"Cabinets handles should be in alignment, Not rusted <br>and fixed properly"<br>
-
Are all skirting installed and free of gaps?<br>
-
Fire Extinguisher and fire blanket is installed and in good condition<br>
-
No gaps between walls and ceiling termination<br>
-
Is the mirror in good condition? <br>
-
Is the grouting and silicon in the toilet in good condition?<br>
-
Is under cabinets properly finished?<br>
-
Are the walls properly painted?<br>
-
"paint of walls uniforms in colour & texture without <br>patches, spots, dirt’s, smudges "<br>
-
Painting linear on top of skirting<br>
-
Painting of shadow gap<br>
-
Access panel paining<br>
-
Terminations around all MEP surfaces<br>
-
"10-15 cm above shadow angle or from the <br>soffit of the slab to be plastered and primer <br>painted"<br>
-
"Checking the AC ducting are not in conflict <br>with the suspension system"<br>
-
"Bitumen layers anti-bacterial, anti-fungus as <br>specified"<br>
-
Level of ceiling, non-undulated, No sagging<br>
-
Linearity of Bulkhead, edges and shadow gaps<br>
-
"Shadow Angles should be uniform and gap to be <br>uniform"<br>
-
Equal gaps around access panels<br>
-
Is the unit clean?<br>
-
Are all door stoppers installed and in good condition?<br>
-
Is there any broken/ scratched glass?<br>
-
Are balcony doors and windows working properly? Locks working?<br>
-
Are all aluminium work free of scratches paint stains? <br>
-
"Alignment of Aluminium frames to be <br>checked with no defect "<br>
-
"Proper finishing at the joints and around <br>the Aluminium frame,"<br>
-
"Aluminium & Glass - Silicon applied properly in linear lines, <br>and in equal gaps"<br>
-
Glass to be clear from the scratch<br>
-
"Aluminium & Glass -Handles and Accessories to be fixed in <br>alignment and rain stoppers should be <br>fixed as well,"<br>
-
Metal Works - Fixing as per approved MS and drawings,<br>
-
"Metal Works - Checking the paining, scratch, rust, quality of <br>texture and colour"<br>
-
"Metal Works - Alignment of any metal member should be done <br>properly"<br>
-
"Metal Works - Safety considerations in all metal works to be <br>considered"<br>
-
"Marble - No cracks, no variation in colour, No dents, No <br>veins, proper edges chamfering and as per approved <br>sample, Proper polishing if specified"<br>
-
Is fly mesh installed properly without damage?<br>
-
Is there any wall gaps above false ceiling?<br>
-
All skirting with proper alignment and terminated properly to the wall? <br>
-
Is shower floor area with proper slope?<br>
-
Above ceiling is free from any construction waste/stored items?<br>
-
Plaster hollow Sound<br>
Electrical Work:
-
Is the door bell/intercom working?<br>
-
Are all lights working?<br>
-
Are all sockets and switches working?<br>
-
Is water heater working?<br>
-
All wires are terminated properly?<br>
-
Is DB load schedule available?
HVAC System
-
Is AC working Properly? Room Temp is achieving 22-23 Degree<br>
-
Is AC cooling? Not noisy? AC thermostat in good condition? <br>
-
Is FCU actuator is automatically closing?<br>
-
Is FCU U trap is installed with proper slope?<br>
-
No condensation observed on the chilled water pipe insulation.<br>
-
Filters and ducts are cleaned?<br>
-
All fresh air intake dampers are opened as per testing and commissioning report?<br>
-
The FCU units are accessible for maintenance (Filters, Actuators, strainers are reachable)<br>
Plumping System and Sanitary ware
-
Is the wash basin and mixer working and in good condition?<br>
-
All floor trap cover are installed?<br>
-
No half moon appear for drains and floor traps?<br>
-
All floor trap cover are installed?<br>
-
Is WC seat and seat cover in good condition?<br>
-
Is the hand spray working and in good condition?<br>
-
Is the bathtub/shower in good condition with the shower mixer and shower head?<br>
-
Are all bathroom accessories (soap dish, towel holder, tissue holder, etc...) available and in good condition?<br>
-
Is Flushing mechanism is working properly?<br>
Testing
-
Wall tested and scanned for moisture?<br>
-
Air supply temperature is checked?<br>
-
Noise level for FCUs and extract fans are check and found with in acceptable range?<br>
-
All sockets are tested with socket tester?<br>
-
fiber optic cable is tested?<br>
-
Thermal imaging is conducted to identify possible leaks from building envelope?<br>
-
Humidity ratio was obtained and found in acceptable level?<br>
-
Pressure test for plumping system is conducted?<br>
-
Drains are clear from blockage?<br>
-
Ponding test is conducted and passed for bathtub sides?<br>
-
Floor and wall tile taping test is done and free from hollowness?<br>
-
Testing and Commissioning of distribution Board<br>