Title Page

  • Site conducted

  • Conducted on

  • Prepared by

  • Location
  • Level

  • Elevation

  • Section

  • Gridlines

  • Core / Apartment (Apt)

Setting out - Gridline/Datum

  • Drawing ref number:

  • Has all SFS been installed at this location?

  • Is SFS set out correctly to gridline and/or datum?

Deflection

  • Has 25 mm minimum been allowed for deflection?

  • Has the correct deflection brackets been installed?

Head Track

  • Have the correct heavy duty tek fixings 2No 6.5x45 TAPCON ANCHORS been used to fix to the concrete?

  • Are head tracks fixed to the substructure as per detail?

Studs

  • Have the studs been installed to the correct centres, maximum 600 mm?

  • Have the correct fixings 2No 5.5dia TEK SCREWS been used?

Base Track

  • Have the correct heavy duty tek fixings 2No 6.5x45 TAPCON ANCHORS been used to fix to the concrete?

  • Fixings to the substructure as per detail?

Sheathing Board

  • Typical board fixing to SFS

    Detail illustration.jpg
  • Is the sheathing board installed a Siniat Weather Defence?

  • Have fixings self drilling screws been used to fix the board onto SFS?

  • Are the self drilling screws at maximum 600 mm centres?

  • Are the self drilling screws at a minimum of 13 mm and maximum 20 mm from joints?

  • Are all the joints sealed with Fire Rated Silicone Sealant or Weather Defence Joint Tape?

Sign Off

  • On behalf of Jessella

  • On behalf of the Client

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.