Information
-
Document No.
-
Client / Site (FSAM/FDA)
-
Contractor being audited
-
Ticket Of Work Number (Enter last 8 digits number after T1W0000, for example, if TOW is T1W000012341234, you only have to enter 12341234)
-
Worksite Address
-
Conducted on
-
Prepared by
-
Location
Underground Installation
-
New LIC installed at correct depth (300mm on premise & 450mm when installed greater than 3m along street
-
New LIC entering pit correctly and has been fitted with bush
-
New LIC correctly sealed with rubber sealing plug (only when LIC enters building or there is a chance of water egress)
-
Where a new LIC has been installed, 2 Saddles have been used to secure the LIC to the premise?
-
LIC details correctly recorded on Job Completion Form & asbuilt in iToW
-
SDS correctly supported and housed in pit (2-3m of slack)
-
SDS labeled correctly in pit as per labelling guideline
Aerial Installation
-
Correct aerial attachments/points used on pole
-
Correct aerial attachment/points used at permise
-
Minimum clearances maintained? e.g. over roads/driveways, from existing comms infrastructure, LV/HV cables to local utility standards
-
Correct riser size and location on pole installed installed in accordance with NBNCo and local utility standards?
-
Riser has been installed and fastened correctly as per relevant specifications?
-
A cable drip loop has been installed at both the multiport and the PCD?
SDS Installation
-
SDS cable connected to correct port at MPT?
-
SDS Cable installed as per specification?
PCD Installation
-
PCD mounted correctly (where possible adjacent or above Telstra connection box)?
-
PCD mounted vertically with latches on right hand side?
-
PCD clearances as per specifications?
-
SDS cable installed and terminated correctly in PCD (SDS not exposed between lead in pipe and PCD)?
-
Unused optical connectors have caps/plugs installed?
-
SDS labelled correctly at PCD as per labeling guideline
General
-
Reinstatement of LIC installation as per reinstatement guidelines?
-
All rubbish/waste removed from site (including cable tie stubbs)?
-
Site left safe and tidy (brick dust cleaned up)?
-
Comments:
-
Add signature