Title Page
-
Simpro Job Number
-
Date Inspection conducted
-
Staff Member
-
Address
-
REC - 30417
Safety Inspection
Switchboard Safety
-
1 RCD test: trip time, current & push button test
-
2 RCD test: trip time, current & push button test
-
3 RCD test: trip time, current & push button test
-
4 RCD test: trip time, current & push button test
-
5 RCD test: trip time, current & push button test
-
6 RCD test: trip time, current & push button test
-
7 RCD test: trip time, current & push button test
-
8 RCD test: trip time, current & push button test
-
9 RCD test: trip time, current & push button test
-
10 RCD test: trip time, current & push button test
-
Is there electrocution protection (RCD) installed on all power general power and lighting circuits as required by rental laws?
- Yes
- No
- N/A
-
Are there any known recalled products installed?
-
Are there ceramic fuses installed?
-
Are all circuit protection devices correctly sized?
-
Correct circuit connections (Polarity)
-
Is there an appropriately rated main switch installed?
-
Type of connection to switchboard?
-
Point of attachment condition?
-
Point of attachment conductor connections
-
Main earth type
- Earth electrode
- Strip earth
- Equipotential bond to water pipe
-
Is the main earthing conductor 6mm2?
-
Does the main earth electrode have identification tag installed?
-
Are the main earth connections protected against mechanical damage?
-
Earth continuity test less than .5 ohms
-
Is strip earth size 25mm2?
-
Conductor size 6mm2?
-
Does the bond location have a identification tag installed?
-
Earth continuity test less than .5 ohms
-
Are the main earth connections protected against mechanical damage?
-
Is the switchboard adequately bonded?
-
Location of main earth identified at switchboard?
-
Is the MEN link installed and correctly sized?
-
Photo of MEN link
-
Is the switchboard structurally sound?
-
Is the switchboard adequately fire sealed?
-
-
Are the circuits correctly identified?
-
Could the switchboard contain asbestos based materials?
-
Is there any sub-standard cabling present inside the switchboard?
-
Is there any sign of rodent damage?
Smoke Alarm Safety
-
Photo of existing smoke alarm
-
Are there smoke alarms installed?
-
Are the smoke alarms hardwired 240V?
-
Are the smoke alarms in date?
-
Smoke alarm date of expiry
-
Are the correct number of smoke alarms install in the correct locations?
-
Do the smoke alarms operate under test conditions?
-
What type of smoke alarms are installed?
-
Are the smoke alarms required to be interconnected?
-
Replacement of smoke alarm evidence
Functionality Assessment
-
Are all light fittings functional?
-
Location and fault description
-
Are all power socket outlets in good condition and have correct polarity?
-
Location of faulty powerpoint with description
-
Are all switches operating correctly?
-
Location and type of switch needing to be replaced
-
Does oven work?
-
Does the oven light and knobs work?
-
Does the rangehood fan work?
-
Does the rangehood lights work?
-
What type of globe is required?
-
Electrical connection terminals covered and connected properly?
undefined
-
Electrical safety check is carried out in accordance with section 4 of AS/NZS 3019 “Electrical installations—Periodic verification”, we are not liable for any assessments carried out, or information contained within, as some installations will be applicable to previous standards.
Note: cabling that is contained within the fabric of the building has not been checked.
Approximately 10% of the electrical installation has been checked to give an approximate indication of the safety of the electrical installation