Title Page
-
Address
-
Permit #
-
Date
Exterior
-
Address numbers, minimum 4” contrasting to background
-
Landing at required exterior doors
-
Sewer Cleanout above grade
-
Backflow preventer outside spigots
-
A/C unit installed and on solid level platform
-
A/C unit circuit ampacity / breaker / fuse size verified
-
Equipment not located in side yard setback
-
GFCI receptacle within 25 ft. of outdoor A/C unit
-
Weather resistant receptacles GFCI w/ “code keeper” covers
-
Switched light at pedestrian entrances
-
Driveway & sidewalk completed per City standard
-
Final grade/site clean of debris and overgrown weeds
Exterior/ Decks
-
Joist hangers on decks on ledger board and rim board
-
Ledger board attached with approved fasteners
-
Ledger board flashed or ½‟ spacers
-
Guardrails as required by IRC R312.1, w/ minimum 36” height
-
Baluster spacing must not permit the passage of a 4” sphere
Garage
-
Rated or solid core wood door between garage and dwelling
-
Overhead garage door rated for 90MPH wind load
-
Furnace elevated 14” above finished floor
-
Receptacle GFCI protected except dedicated single receptacle
Kitchen
-
Drain line for dishwasher secured above sink bowl
-
Kitchen counter top receptacles GFCI protected
-
Spacing of general & small appliance circuit receptacles
-
Makeup air when exhaust hood exceeds 400 cfm
Bathrooms
-
Fixtures caulked, non-absorbent, smooth, impervious surface
-
Water closet, 15” ₵side and 21” front clearance
-
GFCI receptacle within 36” and adj. to each bathroom basin
-
Bond metallic water lines for hydro-tubs
-
GFCI protection for hydro-tub pump is readily accessible
Mechanical room
-
Water heater T&P relief & discharge pipe to drain
-
Combustion air provided, full louvered if louvered door
-
Vents properly connected, ¼” rise per foot
-
Clearance, vent to combustibles - 1” „B‟ vents, 6” single wall
-
Condensate to indirect drain, 1/8” slope
-
AC coils located above living space must have overflow protection (drain pan with float switch or secondary drain line)
Electrical panel
-
Electrical panel legend completed and legible
-
GEC connection to electrode/s location marked on panel
-
AFCI protection required on all 15 and 20 amp circuits in bedrooms (including smoke detectors)
-
Individual circuits required for sump pumps
-
Energy conservation label completed and approved
-
Bathroom basin receptacles dedicated 20 amp circuits
Laundry room
-
Make-up air for laundry room, minimum 100 square inches
-
Dryer duct length posted, w/ number of elbows in dryer area
Basement
-
Enclosed accessible space under stairs shall be protected on the enclosed side with a 1/2-inch gypsum board.
-
Receptacles in unfinished area GFCI protected except single type dedicated receptacle
-
Exterior envelope insulated
Windows
-
Egress window in bedrooms, maximum 44” sill height
-
Operable windows >6‟ above grade, minimum sill height 24”
-
Egress window well minimum 36” X 36”
-
Egress window well >44” deep perm ladder/steps provided
Stairs
-
Minimum 36” in width
-
Handrails may project up to 3½” on each side of stairs
-
Rise not less than 4” or more than 7 ¾” w/ uniform rise
-
Tread not less than 10” w/ uniform run
-
Minimum headroom 6‟ 8”
-
Floor or landing at top and bottom of stairs
-
Wall or guardrail on each side of stairs
-
Light switched at top & bottom of stairs
Handrails
-
1¼” – 2” diameter or equivalent gripping surface
-
Minimum 1½” from wall, continuous and returned
-
34”-38” height measured from front of stair tread
-
Handrails for stairs 4 or more risers
-
Baluster spacing must not permit passage of 4” sphere
Smoke/Carbon Monoxide alarms
-
Battery backup
-
Smoke detector in each sleeping room
-
Smoke and carbon monoxide detector on all sleeping levels in vicinity of bedrooms
-
Smoke detector on every level
-
Electrically interconnected
-
Sounding detector required
Building/Mechanical/ Electrical/ Plumbing
-
Tamper resistant receptacles below 5 1/2 feet
-
All GFCI‟s shall be readily accessible
-
Framed 22” X 30 attic access
-
Ground clamp securely fastened and accessible
-
Gas piping bonded at gas service entrance (#6 copper)
-
Listed inter-system bonding termination point provided
-
Label on exposed radon vent pipes
-
Water pressure between 20-80psi
-
Test Pressure:
-
Whole house energy test report received/approved
Other/Notes
-
If applicable, describe code violations, safety issues, or corrections needed:
Sign Off
-
This dwelling has been inspected for all items contained in this checklist.
-
Final Inspection Status
-
Inspector's Name and Signature