Title Page

  • Address
  • Permit #

  • Date

Exterior

  • Address numbers, minimum 4” contrasting to background

  • Landing at required exterior doors

  • Sewer Cleanout above grade

  • Backflow preventer outside spigots

  • A/C unit installed and on solid level platform

  • A/C unit circuit ampacity / breaker / fuse size verified

  • Equipment not located in side yard setback

  • GFCI receptacle within 25 ft. of outdoor A/C unit

  • Weather resistant receptacles GFCI w/ “code keeper” covers

  • Switched light at pedestrian entrances

  • Driveway & sidewalk completed per City standard

  • Final grade/site clean of debris and overgrown weeds

Exterior/ Decks

  • Joist hangers on decks on ledger board and rim board

  • Ledger board attached with approved fasteners

  • Ledger board flashed or ½‟ spacers

  • Guardrails as required by IRC R312.1, w/ minimum 36” height

  • Baluster spacing must not permit the passage of a 4” sphere

Garage

  • Rated or solid core wood door between garage and dwelling

  • Overhead garage door rated for 90MPH wind load

  • Furnace elevated 14” above finished floor

  • Receptacle GFCI protected except dedicated single receptacle

Kitchen

  • Drain line for dishwasher secured above sink bowl

  • Kitchen counter top receptacles GFCI protected

  • Spacing of general & small appliance circuit receptacles

  • Makeup air when exhaust hood exceeds 400 cfm

Bathrooms

  • Fixtures caulked, non-absorbent, smooth, impervious surface

  • Water closet, 15” ₵side and 21” front clearance

  • GFCI receptacle within 36” and adj. to each bathroom basin

  • Bond metallic water lines for hydro-tubs

  • GFCI protection for hydro-tub pump is readily accessible

Mechanical room

  • Water heater T&P relief & discharge pipe to drain

  • Combustion air provided, full louvered if louvered door

  • Vents properly connected, ¼” rise per foot

  • Clearance, vent to combustibles - 1” „B‟ vents, 6” single wall

  • Condensate to indirect drain, 1/8” slope

  • AC coils located above living space must have overflow protection (drain pan with float switch or secondary drain line)

Electrical panel

  • Electrical panel legend completed and legible

  • GEC connection to electrode/s location marked on panel

  • AFCI protection required on all 15 and 20 amp circuits in bedrooms (including smoke detectors)

  • Individual circuits required for sump pumps

  • Energy conservation label completed and approved

  • Bathroom basin receptacles dedicated 20 amp circuits

Laundry room

  • Make-up air for laundry room, minimum 100 square inches

  • Dryer duct length posted, w/ number of elbows in dryer area

Basement

  • Enclosed accessible space under stairs shall be protected on the enclosed side with a 1/2-inch gypsum board.

  • Receptacles in unfinished area GFCI protected except single type dedicated receptacle

  • Exterior envelope insulated

Windows

  • Egress window in bedrooms, maximum 44” sill height

  • Operable windows >6‟ above grade, minimum sill height 24”

  • Egress window well minimum 36” X 36”

  • Egress window well >44” deep perm ladder/steps provided

Stairs

  • Minimum 36” in width

  • Handrails may project up to 3½” on each side of stairs

  • Rise not less than 4” or more than 7 ¾” w/ uniform rise

  • Tread not less than 10” w/ uniform run

  • Minimum headroom 6‟ 8”

  • Floor or landing at top and bottom of stairs

  • Wall or guardrail on each side of stairs

  • Light switched at top & bottom of stairs

Handrails

  • 1¼” – 2” diameter or equivalent gripping surface

  • Minimum 1½” from wall, continuous and returned

  • 34”-38” height measured from front of stair tread

  • Handrails for stairs 4 or more risers

  • Baluster spacing must not permit passage of 4” sphere

Smoke/Carbon Monoxide alarms

  • Battery backup

  • Smoke detector in each sleeping room

  • Smoke and carbon monoxide detector on all sleeping levels in vicinity of bedrooms

  • Smoke detector on every level

  • Electrically interconnected

  • Sounding detector required

Building/Mechanical/ Electrical/ Plumbing

  • Tamper resistant receptacles below 5 1/2 feet

  • All GFCI‟s shall be readily accessible

  • Framed 22” X 30 attic access

  • Ground clamp securely fastened and accessible

  • Gas piping bonded at gas service entrance (#6 copper)

  • Listed inter-system bonding termination point provided

  • Label on exposed radon vent pipes

  • Water pressure between 20-80psi

  • Test Pressure:

  • Whole house energy test report received/approved

Other/Notes

  • If applicable, describe code violations, safety issues, or corrections needed:

Sign Off

  • This dwelling has been inspected for all items contained in this checklist.

  • Final Inspection Status

  • Inspector's Name and Signature

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.